Get complete information related to latest Biopsy Needles Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Biopsy Needles Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Biopsy Needles Tenders.
Tender For supply of 16949 - xylocain cartridge holder, stainless steel "dental cartridge aspirating syringe, stainless steel anesthesia syringes dental instrument - the syringe handle can be reused after sterilization. both 1.8ml and 2.2ml dental cartridge can be used. convenient to put anesthetic ampoule into the barrel and install dental needle. convenient to observe the anesthetic through transparent material. non slip grip premium quality handle. polish to high standard finish. fully guaranteed against defect in material and workmanship. manufactured from high quality medical grade stainless steel. high degree of precision and flexibility while conducting the clinical procedure. high degree of aesthetic and corrosion resistance. product fully conformed to ce marked, iso 9001, iso 13485, and standards." [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of d cfa re 28 disposable shoe cover , d cfa re 28 laryngoscope adult bulb for , d cfa re 28 lighted intubation stylet smallmediumlarge , d cfa re 28 supraglottic device with non-inflatable cuff gastric drain port i gel for size 3 4 5 , d cfa re 28 medium and high concentration oxygen seethrough masks pvc with 7 ft dot oxygen supply tubing adult dot , d cfa re 28 medium and high concentration oxygen seethrough masks pvc with 7 ft dot oxygen supply tubing paediatric , d cfa re 28 nasal cannula paediatric , d cfa re 28 needle epidural anaesthesia with luer lock fitting with stylet 18g ss , d cfa re 28 needle spinal anaesthesia with luer lock fitting with stylet 22g ss , d cfa re 28 needle spinal anaesthesia with luer lock fitting with stylet 24g ss , d cfa re 28 needle spinal anaesthesia with luer lock fitting with stylet 25g ss , d cfa re 28 silicon full face mask for bipapcpap machine , d cfa re 28 tube endo-tracheal armoured stylet for , d cfa re 28 tube tracheostomy with inflatable cuff size 30 fg , d cfa re 28 disposable aprons , d cfa re 28 heavy duty gloves , d cfa re 28 strip indicators for sterilisation control for testing sterility of drums , d cfa re 28 tru cut biopsyneedles 18g , d cfa re 28 insulin disposable syringe 1 ml , d cfa re 28 pack nasal merocel 8cm and 4cm with string , d cfa re 28 spray universal micromotor and hand piece for clense and lubricnt with spry head 500ml , d cfa re 28 double lumen catheter cannula with guide wire introducing needle and dilator , d cfa re 28 elbow crutch aluminium adjustable height with rubber ferule dot ) /bid number : gem/2026/b/7548094 * /dated: 16-05-2026 & & / bid document 1 / 24
Tender For corrigendum : supply of srphc82644035-triple blood bag cpd-sagm 450ml.it should have 450ml capacity with 63ml cpd solution and is connected to one satellite transfer bag of 450ml capacity andone satellite transfer bag of 450 ml with 100 ml sagm.needle should be 16g with triple bevel design to reduce penetration force and enable painless vein puncture.mother bag should be with good quality to prevent breakage during centrifugation andthe inner diameter of the tubes should be with good quality to provide easy flow of the component.blood bags should have hot markings in all tubes of the transfer bags. tubes of plasma, platelet and red cell should have hot marking numbers to ensure traceability. should be made of pvc with plasticizer approved as per indian pharmacopoeia/dcgi.the transfer bag for platelet collection should contain plasticizer compatible forstorage of platelets upto 5 days.blood bags and its packing should be properly labeled with batch. no., date of mfg., and date of expiry. product labels should be barcoded as per isbt-128.secondary packing and shipping cartons should be barcoded as per gs1-128 bags should be packed in an outer cover with sufficient barrier properties toprevent moisture loss during storage.the plastics container and the anticoagulant/additive solution shall have been sterilized by steam sterilization or any other validatedmethod.the method of sterlization used shall not adbersely affect the materials or contents ,nor cause any loosening of joints and deterioration of welds in the plastics material nor any major alteration in the shape of the plastics container.blood bags must conform to iso 3826 and indian pharmacopoeia for container,design,plastic(physical,chemical,biological)anticoagulant,labels,and needle.needle must conform to iso 1135-3.proof of compliance with iso 3826 and iso 1135-3 should be submitted bycompany.market standing of more than 05 years. donor tube is provided with luer adapter for online withdrawal of blood samples without contamination.needle injury protector,predonation bag are also provided to ensure more safety.[quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of 14135 - foleys catheter no. 14 "sterile foleys catheter usage -for single use only method of sterilization- eto sterilization standard conformity to standard - is latest bis marked product - yes product information material of catheter -natural rubber latex catheter size (fg) - 14 length of catheter (mm) - 400 mm balloon capacity (ml) - 30 ml firm thickened bluntly tapering cushion provided at the tip - yes silicone coating provided to the rubber - yes packing & marking packaging & marking shall be as per is latest - yes packing type - each catheter double packed in a leak-proof bag " [ warranty period: 30 months after the date of delivery ]