Get complete information related to latest Biosafety Cabinet Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Biosafety Cabinet Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Biosafety Cabinet Tenders.
Tender For corrigendum : supply installation and commissioning lab equipments , etc - package1, anemo meter, binocular dissecting microscope, binocular microscope, cod analyser, digital colony counter, digital tds meter, dslr camera, farmel s photometer, ganongs photometer, ganongs respirometer, microscopic camera, moll.s half leaf apparatus, ph meter, slide cabinet with 12 showcase, slide reader, mirowave oven, compound micrscope, dissecting microscope, research microscope with digital photography, micropipette 10, micropipette 20, micropipette 100 l, herbarium cabinet, water and soil testing kit, dna isolation kit, colorimeter, auxanometer, noise level meter, ph electrode, water bath double wall, tissue culture rack, dissolved oxygen meter, slide box 50 slides, dissection kit, osmotic pressure appratus, micro tips 10 l, micro tips 200 l, d.o. meter, digital conductivity meter, ph meter, digital balance, magnetic stirrer, digital colorimeter, melting point apparatus, digital potentiometer, water bath rectangular, polarimeter, refrigerator, reflux condenser, chemical storage rack, h2s gas keep apparatus, vacuum pump, melting point/boiling point apparatus, sprayer with rubber bulb, exhaust fan, desiccator, chromatography jar, mortar and pestle, gas lighter, stop watch, laminar air flow/ laminar hood, electrophoresis unit (horizontal) with power supply, autoclave, gel documentation system, centrifuge, colony counter, homogenizer, incubator (orbital shaking), ph meter (microprocessor based), bod incubator, cod analyser, tds meter, digital thermometer, flame photometer (photo diode sodium, potassium,, soil and water analysis kit, mili-q water purifier, micropipette10 l, micropipette 20 l, micropipette100 l, micropipette1000 l, turbidity meter, stethoscope, sphygmomanomet er, cold box, glucometer, anatomy structure model stomach part (human torso complete), anatomy structure model ent part, anatomy structure model digestive system, anatomy structure model genital and pelvis, colorimeter, pcr tube (tarsons individual pcr tube 0.5 milliliter), micro tip box 10-200 l, micro tip box 100-1000 l, micro tip box 1-20 l, micro tips 200 l, micro tips 1000 l, pcr tube 0.5 l, pcr tube 0.2 l, reagent bottle 100 ml autoclavable, reagent bottle 500 ml autoclavable, eppendorf 15 ml, inoculating loop, petridish 75 mm, falcon tube 15ml, falcon tube 50ml, dna-isolation kit, refrigerated micro-centrifuge, centrifuge tube, thermo-mixer, mortar and pestle, petri dish, dissection kit, nanodrop (biored), conductivity meter, research microscope with digital photography, ultra low temperature lab deep freezer (-80c), analytical balance, ultra centrifuge, deep freezer (-20 degree c) blue star 401-500 liters, refrigerator (4 degree c) double door, electrophoresis unit (vertical) with power supply, thermocycler semi-quantitative, conical flask 100 ml autoclavable, conical flask 500 ml autoclavable, conical flask 1000 ml autoclavable, beaker 50ml, cover slip 10 box, petridish 75mm, beaker 50ml, beaker 250 ml, conical flask 250ml,500ml, water cooler with purifier, rydberg s constant using hydrogen discharge tube, frank hertz experiment, fabry- parot etalon, millikan s oil drop method, pn-junction diode, zener diode, pnp/npn transister(ce and cb mode), jfet, electricalkettle with variable voltages, platinum resistance thermometer, electromotive force of a thermocouple, clement- desorme s method, thermal conductivity using calorimeter, mechanical equivalent using joule calorimeter, critical constant of a gas/vapour, poiseuille s method, maxwell s needle appratus, determination of moment of inertia, determination of force constant of a spring, lcr circuit, determination of poisson s ratio of rubber, lissajous figures with the help of cro, melde s experiment, i- curve byspectrometer, prism using sodium light, newton s ring (plano-convex), liquid using newton s ring, sodium light using plane defferaction grating, polarimeter, resolving power of a telescope, charging and dischar
Tender For supply of following items for setting up measurement and instrumentation lab for 4 year b.tech in electrical engineering curriculum and application for university of calcutta. - experimental set-up for calibration of a wattmeter using dc potentiometer with following features/items:regulated power supply 2 volts, 100 ma to operate the potentiometer.calibrated electronic standard cell voltage 1.0186 volts.regulated power supply 0-5 volts/0.5 amps with milliammeter 0- 500ma for current coil of wattmeter.regulated high voltage power supply 0-250 dc volts with voltmeter 0-250 volts for pressure coil of wattmeter.a panel mounting wattmeter 0-125 watt is required to perform the experimentgalvanometer for null balance.a volt ratio box for measurement of higher voltage.complete circuit diagram with wattmeter connections to be provided on the front panel of the instrument.with standard accessories, experimental set-up for low resistance measurement using kelvin s double bridge with following features:range: 0.2 micro ohm to 11 ohms, with an accuracy of 0.05 %required accessories:spot reflecting galvanometer. dc source 10 a with one analog current meter. attachment of 1 meter length.brass clamp with terminals for zero setting. with standard accessories, experimental set up for unknown capacitance measurement using de-sauty s bridge with following specifications:source: sine wave signal of 1khz. the amplitude of ac switch indicating lamp is provided on the bakelite board. two sockets are to be provided for the output of ac signals.detector: for detecting small ac signals in the output, null detector is required as in-built with digital display.circuit diagram:the circuit layout on the board is to be provided out to facilitate convenient working. 4 or 5 mm socket required for making connection. features:r2 --- three decade resistance dials having value 10 1000, 10 100 and 10 10 ohmsr1 ---- single decade resistance dial having value 10 100 ohmsc1 ---- unknown capacitor.c2 ---- two fixed standard capacitors having value 0.01mfd 0.1mfd (loss free)with standard accessories, experimental set-up for calibration of a 1-phase watt-hour meter with following scopes: to adjust & calibrate a single-phase energy meter by direct loading method to adjust & calibrate a single-phase energy meter by comparing with a sub-standard meterspecifications: static energy meter single phase: under test (local) duly mounted, wired and terminated static energy meter single phase: sub-standard meter (isi mark) duly mounted, wired and terminated voltmeter: moving iron ac portable of class 1.0 accuracy and range 0 - 300 v ac ammeter: moving iron ac portable of class 1.0 accuracy and range 0 - 10 a ac wattmeter: dynamometer type ac single phase, multi-range with current coil 5 / 10 amp and potential coil 75 / 150 / 300 v ac variac: variable voltage transformer (portable table / floor mounting type with enclosure) input: 230v ac and output: 0 270v / 8 amp ac variable load: made up of 3 load resistors of 70 ohms / 700 w each duly mounted and connected / terminated to form different loads (35 to 210 ohms) as per external connections digital stop clock: portable with start / stop & reset operation set of necessary 4 mm spring loaded patch cords for interconnections detailed instruction manual supply to be connected: 230v, 1phase, 50 hz, ac mains, experimental set-up for calibration of a 3-phase watt hour meter with following specifications: to adjust & calibrate a three-phase energy meter by direct loading method to adjust & calibrate a three-phase energy meter by comparing with a sub-standard meterspecifications:static energy meter three phase: under test (local) duly mounted, wired and terminatedstatic energy meter three phase: sub-standard meter (isi mark) duly mounted, wired and terminatedvoltmeter: moving iron ac portable of class 1.0 accuracy and range 0 - 300 v acammeter: moving iron ac portable of class 1.0 accuracy and range 0 - 10 a acwattmeter:
Tender For supply of spares/miscellanious items for gis pahalgam for providing reliable power supply during sanjay 2025. - split inverter ac 1.5 ton 5 star hot and cold with avr and other accessories of standard make (for gis pahalgam), servo voltage stabilizer three phase oil cooled p-p 190-450 v : p-n:110-260 v ( with t-oil) , 15 kva (100 ltr. oil capacity), 36v 100ah float cum boast battery charger with full wave rectification for 220v single phase, 50hz ac input supply for (gis pahalgam), 33 kv single core indoor cable kit ( plug in tremination type and screened seperable connectors ) for 400 mmsq cable for gis compatible substaion (brand:- euromold, nexans, raychem etc), 33 kv single core outdoor type cable kit for 400 mmsq, 11 kv single core indoor cable kit ( plug in tremination type and screened seperable connectors ) for 630 mmsq cable for gis compatible substaion (brand:- euromold, nexans, raychem etc)for gis substaion panel mounted, 11 kv three core indoor cable kit ( plug in tremination type and screened seperable connectors ) for 400 mmsq cable for gis compatible substaion (brand:- euromold, nexans, raychem etc)for gis substaion panel mounted, 33 kv current transformer outgoing (33 kv, 1 , multi ratio multi core 600-300/1a, indoor type) (1 no. per ) for gis compatible 33/11kv station panel mounted, 33 kv current transformer incommer (33 kv, 1 , multi ratio multi core 900-600/1a, indoor) (1 no. per ) for gis compatible 33/11kv station panel mounted, 11 kv current transformer outgoing (11 kv, 1 , multi ratio multi core 200-400/1a, indoor) (1 no. per ) for gis compatible 33/11kv station panel mounted, 11 kv current transformer incommer (11 kv, 1 , multi ratio multi core 900-600/1a, indoor) (1 no. per ) for gis compatible 33/11kv station, 11 kv current transformer (11 kv, 1 , multi ratio multi core 600-300/5a, indoor) (1 no. per ) compatible to hartek panels at ais pahalgam, 33 kv current transformer for auxillary (33 kv, 1 , 30/1a, indoor) (1 no. per ) for gis compatible 33/11kv station panel mounted, potential transfromer 33kv/110v (1 , multi core indoor) (1 no. per ) for gis compatible station panel mounted, potential transfromer 11kv/110v (1 , multi core indoor) (1 no. per ) for gis compatible station panel mounted, over current/earth fault (3 o/c and 2 e/f relay abb type for gis compatible 33/11kv substation, providing and fixing 3 layer pp-r (poly propylene random copolymer) pipes conforming to is: 15801, uv stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all pp-r plain and brass threaded polypropylene random fittings. this includes testing of joints complete as per direction of engineer-in?charge. internal work-exposed on wall with clamps at 1.00 meter spacing pn-16 pipe , 25mm od(sdr-7.4) for replacement of damaged pipiline. (for ais and gis )