Get complete information related to latest Bipolar Catheter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bipolar Catheter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bipolar Catheter Tenders.
Tender For corrigendum : e-bid for rate contract cum supply and empanelment of surgical and suture items(rate contract for the period ending on 30.09.2027) -, linear cutter 55mm with six rows, 3d staple formation, option of closed staple height of 1.5mm/1.8mm/2mm in one cartridge only, , linear cutter 75mm with six rows, 3d staple formation, option of closed staple height of 1.5mm/1.8mm/2mm in one cartridge only, , curved green cartridge having close staple height of 2.0 mm, tactile feedback on completion of firing sequence, new anvil, knife with every catridge, , circular stapler 33mm with controlled tissue compression or dst technology with, longer staple leg 4.5 mm to 5.5mm, fixed or tilt top anvil, available in various shaft sizes std. or xl for deeper access, usfada approved, , laparoscopic cartridge for stapler 60 mm blue, 1.5 mm closed staple height with gripping surface technology and six rows compatible with all range of endoscopic linear cutter 60mm, , laparoscopic cartridge for stapler 60 mm green, 2.0 mm closed staple height with gripping surface technology and six rows compatible with all range of endoscopic linear cutter 60mm, , pph stapler 33mm -hemorrhoidal stapler kit consists of 33mm, , hemorrhoidal circular stapler (with fixed anvil, adjustable closed staple height from 0.75 mm-1.5 mm, staple open leg length of 4.0mm -5.5 mm), suture threade, circular anal, , dilator, purse-string suture anoscope, suture for purse string., , optically guided bladeless trocar 12mm with bilateral tissue separators, optical tip to eliminate blind entry, clear ribbed cannula to enhance abdominal wall retention, recessed stopcock valve, funnel shaped housing, duckbill secondary seal, integrated universal seal that eliminates the use of reducer, 150mm length., , optically guided bladeless trocar 12 mm with bilateral tissue separators, optical tip to eliminate blind entry, clear ribbed cannula, recessed stopcock valve, funnel shaped housing, duckbill secondary seal, integrated universal seal that eliminates the use of reducer length 100mm., , facial closure device contain -, , optical bladeless trocar with facial closure device comaptible with clear cannula have two side opening meant for uniform port closure, , varied staple height, , reloads/cartridges for 60 mm, , gia instruments with tri-staple technology, with the cutting knife blade incorporated in the reloads itself, with purple varied staple height of 3, 3.5 and 4mm leg length, , varied staple height reloads/cartridges for 80 mm, , gia instruments with tri-staple technology, with the cutting knife blade incorporated in the reloads itself, with purple varied staple height of 3, 3.5 and 4mm leg length, , eea circular stapler purple colour medium thick, triple row with tristaple technology (three row of staple inner to outer row 3.0,3.5 and 4.0 mm with sloped cartridges face in one stapler) diameter 31mm, , linear cutter with varied, , staple height, tri-staple technology-enabled reloads integration with left and right firing knob(both side firing), linear cutter stapler with integrated gap control technology in 80 mm tristaple gia stapler, compatible with tri-staple gia 80 mm open linear cutter reloads/cartridges purpule and black, , wound protector with double ring in medium 5-9 cm, , endo catch specimen removal kit with continuous ring, polyurethane pouch with 34.5 cm shaft length, 10mm with leakproof and impervious material to cancer cells of 0.5 microns/ pretied purse string on pouch usfda approved, , laparoscopic liner cutter without integrated fresh knife with 360*rotation & 0-45* articulation in both direction: for use with cartridges in sizes of 45mm capable of loading all length cartridges on same gun only, , platting for maxillary swing and mandibular fixation surgeries (titanium) plates - 2 mm thickness (2*2) hole drill bit machine with insertion tools would be provided by the rc holder firm as per need of the respective hospital, , platting for maxillary swing and mandib
Tender For supply of all imported surgical items, as a local purchase for the admitted patients falling under the scheme of ayushman bharat-pradhan mantri jan arogya yojana (ab-pmjay/sehat) and other schemes operative in skims
Tender For supply of all surgical items, as a local purchase for the admitted patients falling under the scheme of ayushman bharat-pradhan mantri jan arogya yojana (ab-pmjay/sehat) and other schemes operative in skims.
Tender For supply of essential drugs, surgical items, biodegradable waste and other material in various sections of government district medical sirohi for the year 2025-26
Tender For corrigendum : e-bid for rate contract cum supply and empanelment of surgical items - sterile hypodermic syringe with needle attached, 24g, single use - 2 ml clear transparent chamber prominent graduation inert material gasket at the piston to minimise friction during movement & prevent leakage and back flow sharp needle ensuring minimum trauma during penetration shall conform to relevant is for syringe - is 10258 and for needle is 10654 packing: needle should be attached with the syringe and packed in unit ribbon pack the words "destroy after single use" or equivalent should be written on unit container., sterile hypodermic syringe with needle attached, 24g, single use - 5 ml clear transparent chamber prominent graduation inert material gasket at the piston to minimise friction during movement & prevent leakage and back flow sharp needle ensuring minimum trauma during penetration shall conform to relevant is for syringe - is 10258 and for needle is 10654 packing: needle should be attached with the syringe and packed in unit ribbon pack the words "destroy after single use" or equivalent should be written on unit container., sterile hypodermic syringe with needle attached, 22g, single use - 10 ml clear transparent chamber prominent graduation inert material gasket at the piston to minimise friction during movement & prevent leakage and back flow sharp needle ensuring minimum trauma during penetration shall conform to relevant is for syringe - is 10258 and for needle is 10654 packing: needle should be attached with the syringe and packed in unit ribbon pack the words "destroy after single use" or equivalent should be written on unit container., sterile hypodermic syringe with needle attached, 22g, single use - 20 ml clear transparent chamber prominent graduation inert material gasket at the piston to minimise friction during movement & prevent leakage and back flow sharp needle ensuring minimum trauma during penetration shall conform to relevant is for syringe - is 10258 and for needle is 10654 packing: needle should be attached with the syringe and packed in unit ribbon pack the words "destroy after single use" or equivalent should be written on unit container.