Tender For corrigendum : supply of m code - 12541 disposable bouffant cap as per drg.no. na specn: na [ warranty period: 30 months after the date of delivery ]
Tender For upums/mm/surgical and dressing consumables/15/2026-27 - long flange adjustable tracheostomy tube 7.0, long flange adjustable tracheostomy tube 7.5, long flange adjustable tracheostomy tube 8.0, small line for etco2, water trap for etco2, anaesthesia disposable kit- adult, dual limb circuit- adult disposable, dual limb ckt dual water trap-adl disposable, bain circuit-adult disposable, "cvc triple lumen with ecg leadtripple lumen central venous catheter seldinger technique having ecg lead and kink proof guide wire with lumen gauge 16, 18 & 18 and catheter length 15cm/20cm. introducer needle with extra angular port for insertion of gulde wire without removal of syringe.", "four lumen cvc line with ecg leadfour lumen central venous catheter seldinger technique having ecg lead and kink proof guide wire with lumen gauge 16, 18, 18 & 14 and catheer length 15cm/20cm. introducer needle with extra angular port(valve needle) for insertion of guide wire without removal of syringe.", "cvc triple lumen antimicrobial with ecg leadtripple lumen central venous catheter -7 fr. should have antimicrobial polymerization with biguanide material-polyhexanide methacrylate, seldinger technique having ecg lead and kink proot nitnol guide wire with lumen gauge 16, 18 & 18 and catheter length 15cm/20cm. introducer needle with extra angular port for insertion of guide wire without removal of syringe.", "cvc four lumen antimicrobial with ecg leadquattro lumen central venous catherter seldinger technique size 8frlength 15/aocm having polyurethane cartheter chemically bonded with biguanide, ecg lead kink proof guide wire with lumen gauge 34, 18, 18816. introducer needle with extra angular port for insertion of guide wire without removal of syringe.", "epidural set-adult 16 glatex-free continuous epidural ancsthesia kit containing 16g cpidural tuohy needle with large crystal clear grooved transparent hub totally inert yellow radio-opaque catheter 20g/18g made of plasticizer free, polyamide core in center with polyurethane coating with graduation markings after every icm from the 5.5cm mark with a special smudged marking for easy calculation of catheter length placed in epidural space, also having small ergonomic 0.2 micron epidural filter with dead volume of 0.45 ml special catheter securing device/connector. catheter having three pairs of lateral eye for drug delivery.", "combined spinal epiduralcombined spinal and epidural anesthesia kit with docking system, back-eye in the curved tip of the tuohy needle 18g, 3.5"", 0.1.3 x 88mm, loss of resistance syringe 10m/, epidural flat filter 0.2 micron, epidural catheter length 0.45 x0.85mm screw connector with pencil point spinal needle 27g x5"", 0.42x138.5mm", "conntinious ultra 360° 18gx2"" (1.3x50mm)continuous plexus set consisting of a 20 degree backcut echogenic needle 18g with x pattern engraved on first 20mm fromtip, a double layer polyamide & polyurethane so mm catheter with three pairs of laser drilled holes tapered tip design, 0.45x0.85×400 mm, provision of single bolus shot with extension tubing, along with snap cap catheter connector, a o.2 micron filter & 5 ml syringe.", "conntinious ultra 360° 18gx2"" (1.3x100mm)continuous plexus set consisting of a 20 degree backcut needle 18g xpattern engraved on first 20mm from tip, a douible layer polyamide & polyurethane 100mm catheter with three pairs of laser drilled holes tapered tip design, 0_45x0.&1000mm, provision of single bolus shot with extensiontubing, along with snap cap catheter connecter, a o, 2 micron filter & 5ml syringe.", "echogenic plexus single shot needlesingle shot echogenic plexus needles having 30 degree bevel & 50 cm long dehp free injection tubing. size-20 g-100/150 mm and 22 g-35/50 mm", "pencil tip spinal needle 25gpencil tip spinal needle 25g/x88mm(3.5inch) with introducer 20gxg5mm", "pencil tip spinal needle 27gpencil tip spinal needle 27gx88mm(3.5inch) with introducer 22gx3.5mm", vent set basic for
Tender For supply of disposable laboratory items - container for urine, sputum, stool sample collection, leak proof with wide mouth, conical wide bottom & screw cap, 50 ml capacity with label for patient name, ward/opd and registration number, pack size – 1 x 100 , esr disposable pipette with tube, tube 13 x 75 mm clean transparent with graduation at 0.4 ml and 2 ml should allow to fill by air pressure through the rubber piston blood lift up – up to zero level. pipette should be made with transparent polystyrene with graduate d scale 0 to 180-200. it should be fine finished; pack size – 1 x 100 , evacuated blood collection tube with spray dried k2edta with lavender safety closure. it should be made of clear latex free polyethylene terphthalate. size – 13 x 75 mm with 4.0 ml, volume capacity. batch wise gamma sterilized /pyrrogenicity/toxicity certificate should be given. it should be iso and us-fda/ce certified. firm should provide training to technicians/nurses regularly for blood collection. clinical services should be documented by company. pack size – 1 x 100 , sodium citrate evacuated tubes for coagulation test with vacuum (with na. citrate – 0.109 m/3.2% plastic tube made of clear latex free polyethylene terphthalaste with light blue safety closure, 13 mm x 75mm vol. 2.7 ml. batch wise gamma sterilized /pyrogenicity/toxicity certificate should be given. it should be iso and us-fda/ce certified, firm should provide training to technicians/nurses regularly. clinical services should be documented by the company; pack size – 1 x 100 ,, evacuated tubes for silica-clot activator/silicon coated made of clear latex polyethylene terphthalate with safety closure 13 x 75 mm vol. 4.0 ml. it should be iso and us-fda/ce certified. batch wise gamma sterilized /pyrrogenicity/toxicity certificate should be given. firm should provide training to technicians/nurses regularly. clinical services should be documented by the company; pack size – 1 x 100 , blood collection needle 21 or 22 gauge with cap for evacuated tube. it should be iso and us-fda/ce certified and gamma sterilized certificate. firm should provide training to technicians/nurses regularly. clinical services should be documented by the company; pack size 1 x 100 , evacuated tube needle holder; pack size – 1 x 5 , "clot activator for serum with gel 3.5 to 4 ml, 13 x 75 mm 1. vacuumized blood collection tube should be suitable for venous blood collection from adults and children2. should be sterile, evacuated and pet and with safety closure and single hand operation for capping and decapping 3. should provide standardized filling of blood and fit snugly on holder. should have fill mark to indicate the draw volume4. shelf life should be minimum 12 months or more from the date of manufacturing 5. the quantity of additives in the respective tube should be as per nccls/clsi guidelines. 6. should provide different color coding cap for different additives.7. the tube should contain a label for noting the patient’s details8. manufacture should provide iso and us-fda/ce certification 9. expiry dates should be printed on blood collection tubes. blood collection should be gamma sterilized. paramedical to be trained10. batch wise sterilized /pyrrogenicity/toxicity certificate should be given. firm should provide training to the technician/nurses regularly, clinical services should be documented by the company (1 x 100)11. adequate/combustion data to prove that it is safe for the environment incineration pack size (1x100)" , "clot activator for serum with gel 5-6 ml, 13 x 100 mm1. vacuumized blood collection tube should be suitable for venous blood collection from adults and children2. should be sterile, evacuated and pet and with safety closure and single hand operation for capping and decapping 3. should provide standardized filling of blood and fit snugly on holder. should have fill mark to indicate the draw volume4. shelf life should be minimum 12 months or more from the date of manufacturing 5