Get complete information related to latest Bitumen Tank Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bitumen Tank Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bitumen Tank Repair Tenders.
Tender For bid to ras supply of ac voltmeter , ac voltmeter 0-150 , ac ammeter , function generator , single phase variac , dc voltmeter 0-15 , dc voltmeter 0-150 , dc ammeter , earth resistance tester , d. c. regulated power supply , tachometer , rheostat , electrical tools bag , electronic work bench , build a voltage divider bias circuit and measure the terminal currents & terminal voltages of the vo , build the ce, cc and cb amplifier circuit and verify the input and output characteristics. and build , dso(100mhz) , v-i characteristics of scr , measurement of current and voltage in a branch of the given electrical circuit using kirchhoff s cur , measurement of load current in load resistance using thevenin s theorem, norton s theorem, maximum p , measurement of open circuit(z) parameter, short circuit(y) and abcd parameter of a two-port network. , characteristics of triac, . , r and rc triggering circuit of scr. , breadboard , b. h curve apparatus kit , demonstration of faraday s laws of electromagnetism. , test the performance of zener diode/pn/led , test the functionality of half wave rectifier and full wave rectifier and bridge , implement logic gates using universal nand gate ic, nor gates and universal gates , half adder and full adder using gates , sr, ms-jk, d and t flip using ic 7476(all in one) , test the functionality of dac and adc using ic. , passive components , r and rc ujt triggering circuit of scr , half wave and full wave converter with r and rl load and freewheeling diode , characteristies of igbt, mosfet, fet , chopper circuit , inverter circuit(series and parallel) , forced commutation circuit (a, b, c, d and e) , single phase step-up and down cyclo converetr , scr single and three phase half-full controlled bridge converter , dc to dc converter trainer (buck, boost and buck-boost converters) , scr single phase dual converter trainer , discrete component trainer , total station , gps instrument , tilting level , two hinged arch , water absorbtion test apparats for aggregate larger than 10mm or between 40mm and 10mm , vessel for water absorbtion test of aggregate smaller than 10mm , miscellaneous tools , cylindrical steel cup, metal hammer , bourdon's gauge , piezometer , flywheel apparatus , laboratory permiability apparatus(constant head and falling head) , calibrating glass tube , steel cylinder, cylindrical metal , jar testing apparatus with jars , burrete, burette stand, conical flask, pippette , bod apparatus , suspended solids, dissolved solids, and total solids measuring apparatus , bod incubator , digital balance, hot air oven , test tubes , beaker , digital thermometer , u tube manometer , dial gauge stand , silver sulphate , dpd (diphenyle paraphenylene diamine indicator , shear strength testing machine , digtal chlorimeter , watt meter
Tender For supply of jockey pump , main pump , diesel driven pump , control panel , cables and electricals , cable tray ms perforated heavy cable , earthing of motors gi strip , pressure switch , pressure gauge , pipelines 200 nb for discharge header , pipelines 200 nb for suction line , pipelines 150 nb , pipelines 80 nb , pipelines 25 nb , ball valve , non return vales 150 nb , non return vales 80 nb , isolation valves 150 nb , isolation valves 80 nb , sluice valves 200 nb , sluice valve 80 nb , vibration eliminator , air vessel , y strainer 200 mm , y strainer 80 mm , vaccum tanks , structural steel , pump for water transfer , panel automation cabling for water transfer pump , rain protection shed for fire pump house , fire water tank zinc , rcc fundation pump asd water tank , air release valve , analogue addressable fire alarm main control panel honewell , hooter cum strobe , uv ir triple detector , smoke detector , probe type heat detector in flame proof enclosures , ms cable tray , monitor module with junction box , control module with junction box , armoured cable above ground , pipelines , hydrant valve , fire hose , branch pipe , hose box , hose reel , rcc pedestal , isolation butterfly valves , mvws nozzle , isolation vlaves , deluge valve , mvws nozzle fittings , gas leakage control panel with batteries , lpg gas detector in flame proof enclosures , prop type heat detector in flame proof enclosures , hooter cum stroble , control module with junction box , 2c x 1.5 mm2 armoured cable above ground , abc, isi marked stored pressure type , co2 type extinguisher conforming to is , 50 ltr trolley mounted fire extinguisher foam type conforming ) /bid number : gem/2025/b/6428772 * /dated: 12-08-2025 & & / bid document 1 / 63
Tender For corrigendum : purchase of biochemistry lab equipments - fully automatic biochemistry analyzerthroughput: 200 photometric tests/hour & 400 tests/hour with ise (optional)reagent positions: 50 cooled reagent positionssample type: whole blood, serum, plasma, urine, csf otherreading volume: 180 lsample volume: 2-70 l (adjustable in 0.1 l)reagent volume: 10-300 l (adjustable in 1 l)light source: halogen lampon board laundry: 6 stage cleaning, 2 stage drying with cuvette validation stepcalibration type: linear, non-linear, multipointprogrammable parameters: default system pack parameters + upto 10 user defined parametersdimensions and weight: ergonomic design and light weight., fully automatic hematology analyzerthroughput-up to 80 samples per hourdimensions and weight ergonomic design and light weighttest mode-cbc, cbc+diffdata storage capacity-up to 100 000 resultscommunication-lan port supports hl7 protocolpower requirement-a.c. 100-240 v, less than or equal to 300 va, 50/60 hzoperating temperature-15 to 30 degree celsiusoperating humidity-30-85%air pressure70-106 kpa, fully automatic immunoassay analyser random assay (hormone analyser)instrument name: immunoassay analyserusage/application-clinicalplate format-random assaydetection method-luminescenceparameters-blood alcohol contentautomation-fully automaticuser input-touchassays-diabetes, thyroid, cardiac, vit d, fully automatic electrolyte analyser-analysis time: 60 second per sample parameters- na , k , cl or ca2+no. of parameters 3 simultaneously90 luser inputs 5 colored touch screen displayelectrode type- sturdy electrode (facility to refill the solution)connectivity 2 usb port, rs232, lisdata storage- 10,000 patient results & 10,000 qc results for 3 levelssample identification- alphanumeric sample idqc management- tri-level quality control, l j plots of last 30 dayscalibration- 2 point calibration on every 4 hours1 point with every samplepower - 100 240 v, 50/60 hz (self adjusting)printer - inbuilt thermal printerroom temperature -15 30 c / 60 90 fhumidity- 85%dimensions and weight - ergonomic design and light weight, centrifuge machine along with 500 prp test tubes (double spin)parameter- neya-16 max speed (rpm)- 15000max rcf (g)- 21000max capacity (ml)- 4 x 175acceleration profiles- 10deceleration profiles- 10display-- multi-color lcdno of programmes- 10 (protected)timer- 30 sec to 99 min & continuous modeergonomic design and light weightsupply - 220v, 50 hz, 1 phasecan be used for extracting prp, autoclavekey features- high-pressure vessel: a high-pressure vessel designed to withstand high temperatures and pressures- temperature control: precise temperature control to ensure effective sterilization- timer and controls: easy-to-use timer and controls for convenient operation- safety features: multiple safety features, such as automatic shut-off and overheat protection, to prevent accidents and ensure safe operationconstruction and materials- stainless steel: a durable stainless steel construction to withstand high temperatures and pressures- insulation: high-quality insulation to ensure efficient heat retention and energy savings- door and seals: a secure door and seal system to prevent steam escape and ensure effective sterilizationperformance specifications- temperature range: 121 c to 134 c.- pressure range: upto 30 psi- cycle time: 15-60 minutes- sterilization capacity in liters or cubic feetsafety standards- compliance with regulations: compliance with relevant regulations, such as asme, fda, and iso standards- automatic safety devices: automatic safety devices, such as overheat protection and low-water cut off, to prevent accidents and ensure safe operation- interlocks: interlocks to prevent door opening during operation and ensure user safetyadditional features- data logging: optional data logging capabilities to track temperature, pressure, and cycle data- printed records: optional printed records of cycle data for documentation and quality control- val
Tender For corrigendum : supply of deluge system equipment for msb unit for nrep - a. deluge water spray systems (mvws system + water curtain system + hvws system)cs deluge valve with dry pilot trim & electric release trim, horizontal inlet & horizontal outlet, without skid, ul/fm approved, complete with dry pilot trim with test, alarm & drain devices, local deluge valve control station (dvlcs) (1 no. per dv), pressure transmitters (02 nos per dv.), 3/3 way sil2 certified intrinsically safe solenoid valve-24v dc (1 no. per dv), pressure gauges (03 nos. per dv), air filetr regulator (afr)(1 no. per dv), air vessel of adequate capacity (1 no. per dv), etc. in compliance with the scheme shown in attached "technical data sheets for fire fighting & safety equipment (tk-1p21a-sa-dat-0001)".the deluge valves shall be supplied with the trim and associated instruments duly assemblied with the deluge valve and with suitable packaging to avoid damage during transportation. the upstream strainer, block valves and by-pass valve including the pipes connecting to these items are not in bidders scope of supply.all items shall be suitable and certified for zone 1,iic,t3 area classification. all electrical and instruments shall be certified for intrinsically safe (ex-ia) and solenoid valve shall be certified to explosion proof (ex-d). all instruments and enclosures (junction boxes/ cabinets/panels/ accessories) in field shall be dust proof and weather proof with ip-67., 200 mm nb, 150 mm nb, 100 mm nb, 80 mm nb, mvw spray nozzle with 1/2" mnpt end connection, moc - stainless steel, ul / fm listed, (with inbuilt strainer): size 15 nb, mvw spray nozzle with 1/2" mnpt end connection, k factor-18, spray angle 120 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-18, spray angle 110 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-18, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-22, spray angle 110 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-22, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-26, spray angle 120 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-26, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-30, spray angle 120 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-30, spray angle 110 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-30, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-35, spray angle 110 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-35, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-41, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-51, spray angle 110 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-51, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., mvw spray nozzle with 1/2" mnpt end connection, k factor-79, spray angle 90 , moc - stainless steel with corrosion resistant coating, ul listed., quartzo
Tender For repair works for damaged fendering system, steel walkway support structure and allied steel works at hoj-ii, inside dock zone, hdc, haldia, caused by vessel bw loyalty.