Get complete information related to latest Blood Bank Equipment Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Blood Bank Equipment Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Blood Bank Equipment Tenders.
Tender For supply, installation and commissioning of vessel sealer, bloodbankequipment, a-scan machine and ups with battery at district combined hospital, gautam buddha nagar, up
Tender For supply and installation of laboratory equipments for bansberia 15 mgd wtp under bansberia municipality. - ph 700 meter,ph 700 meter with glass body open pore ph electrode, atc probe, integral electrode holder & 100/240 vac adapter and with 4, 7 ,10 480ml colored calibration buffer solution,range: -2 to 16, turbidity meter,waterproof tn-100 handheld turbidity meter with set of 4 calibration standards (800, 100, 20.0 & 0.02 ntu), set of sample vials, lint-free cloth, silicone oil, batteries, and hard carrying case,range:- 0 to 2000 ntu, conductivity meter,700 conductivity meter up to 5-point push button calibration, nan-volatile memory that holds up to 100 data points, and integral electrode holder and electrode. along with 1413 calibration solution,range:-0-2000 s/cm, lab weighing machine/ analytical balance,microprocessor based analytical balance, 220 gm capacity, 0.1 mg readability with internal calibration facility, air-shield, ss pan, lcd display, under hook facility, piece counting facility, lq oq pq certificates with internal calibration facility, air-shield,range:-0.1mg to 220 gm, chloroscope test kit ,range 0 05-5 ppm, 500 tests, range:-0.05-5 ppm
Tender For state plan-state plan 2025-2026-procurements of equipments for wtps-supply and installation of water quality testing equipments at wtps under ws section 1 attingal-general civil work-general civil work - purchase of jar test apparatus, od229090/2025-2026:supply and installation of the jar test apparatus must meet the following specifications. no. of. stirrers -6 minimum, rpm- 25 to 200 rpm or better, capacity of single stirrer unit-, control—digital control (digital timer & rpm counter), stirrer paddle material (with appropriate corrosion protective coating) - stainless steel, power single phase (220 - 240 volts), illumination—fluorescent tube such that illumination should not contribute heat to the system and entire equipment must have a minimum warranty period of two years, purchase of ph meter, od229087/2025-2026:supply and installation of bench top ph meter must with the following specifications: (a) regarding ph: the range must be between 0.00 to 14.00 ph or better, the resolution 0.01 or better, the accuracy 0.02 ph or better, the calibration points should be atleast 3 points, buffer option should be suitable for standard buffers. (b) regarding mv: range 0 to 1999 mv, resolution 1 mv or better, accuracy mv or better (c) regarding temperature: range 0.0 to 99 degrees celsius or better, resolution should be 0.1 degrees celsius or better, and accuracy of 0.5 degrees celsius or better. (d) the electrode of the ph meter must be a single junction, body plastic/unbreakable material, gel-filled electrode, and atc probe, and the electrode stand should also be provided by the supplier. (e) ph meter must also have lcd/led display, a dual display of ph or mv with temperature, with auto buffer recognition, offset/slope should be displayed, power 230v 10%, must provide a minimum of 100 ml of buffer solutions of ph 7.0, ph 4.0, and ph 9.2. the supplier must provide all accessories for smooth functioning of the equipment and a hard copy of the user manual with instrument specifications. the ph meter must have a minimum warranty of one year for the meter and a minimum of six months for the electrode. the calibration at the time of the installation must be done by the supplier., purchase of conductivity-tds meter, od229088/2025-2026:supply and installation of conductivity - tds meter with conductivity range of at least 0.1 s to100 ms, resolution : 0.001 s and tds range of 0.1 ppm to 100 ppt , temperature : 0 degree celsius to 1000 degree celsius (auto / manual), readout : 7 digits led (3 digits for temp. and 4 digits for cond./tds), printer interface for 80 column d.m. printer with minimum one year warranty
Tender For supply of ph probe range 0 to 14 cale 15 meter , 36100705 conductivity probe k 0.01 hach , 36100705 conductivity probe k 0.1 hach , single channel conductivity analyzer , 3610080401 ph controller ph7685
Tender For corrigendum : supply of consumables for pathology dept - pbs powder ph 7.0 to 7.5 500gm , ssc 20x solution , bcr abl1 probe fusion probe , her2nue probe amplification probe , dapi antifade for fish , anti body fitc c1q for direct immunofluoresence , xl aml1 eto xlt 8 isto 2 translocation dual fusion 100 micro litre fish probe , xl pml rara xlt is isto 17 translocation dual fusion 100 microlitre fish probe , proteinase k powder from tritirachium album 100mg , ana anti nuclear antibody. indirect immunoiflourescence assay kit , dna ffpe kit 250 reaction , egfr mutation diagnostic kit 29 targets 52 reaction real time pcr. detection includes controls , microtips 10 microlitre , advance hydrophobic pen for ihc. please refer pdf file for speicification