Tender For supply of portable joint gasket cutting machine as per encl , hydraulic nut cracker as per encl , safety helmets with detachable rechargeable led lamp , rechargeable safety torch , rotary hand pump as per encl , led type potable hand lamp , non contact tachometer , refrigerant gas detection and extraction kit , bilge water jet cleaning machine , air blower for electronic cabinet , cylinder shifting trolley , portable lift for oil drum , optical fibre repair kit , kitiwakelub oil analysis kit as per encl , portable vibration measuring equipment , suction cleaner for electronic cabinet
Tender For corrigendum : providing of operation and maintenance of other machines and plants - operation & maintenance of municipal cleaning and waste management equipment (including truck mounted road sweepers, truck mounted sewer suction cum jetting machine, refuse compactors, and supe..
Tender For corrigendum : purchase of surgical items and sutures at bundi - surgical and sutures, absorbable gelatin sponge ip 66, size 80(+-10) mm x 50 mm x 10 mm should be sterlized., asepto syringe with transparent bulb sterile, 60 ml, blood administration set / blood transfusion set sharp and easy piercing spike suitable for blood bags and standard blood containers transparent cylindrical drip chamber with filter.filter size should be 200+20 micrometer. 150 cm long smooth kink resistant tubing efficient roller clamp to control and adjust the transfusion rate should conform to is 9824(part 3):1996, disposable sterile surgical rubber gloves size 6 inches made of natural rubber latex, powdered, without tear, properly folded in a paper free of holes, with acceptable quality level (aql) of 1.5 or less tensile strength as per en 455-2 powder should be non-allergenic should conform to is 13422 isi marked / ce certified / fda approved, disposable sterile surgical rubber gloves size 6 inches made of natural rubber latex, powder free (polymer /silicon coated), without tear, properly folded in a paper free of holes, with acceptable quality level (aql) of 1.5 or less tensile strength as per en 455-2 should conform to is 13422isi marked / ce certified / fda approved (ce certification / fda approval for item is mandatory for importer firms, that cannot avail is standards), disposable sterile surgical rubber gloves size 7 inches made of natural rubber latex, powdered,,without tear, properly folded in a paper free of holes, with acceptable quality level (aql) of 1.5 or less tensile strength as per en 455-2 powder should be non-allergenic should conform to is 13422 isi marked / ce certified / fda approved, disposable sterile surgical rubber gloves size 7 inches made of natural rubber latex, powder free (polymer /silicon coated), without tear, properly folded in a paper free of holes, with acceptable quality level (aql) of 1.5 or less tensile strength as per en 455-2 should conform to is 13422isi marked / ce certified / fda approved (ce certification / fda approval for item is mandatory for importer firms, that cannot avail is standards), disposable sterile surgical rubber gloves size 7 inches made of natural rubber latex, powdered, without tear, properly folded in a paper free of holes, with acceptable quality level (aql) of 1.5 or less tensile strength as per en 455-2 powder should be non-allergenic should conform to is 13422 isi marked / ce certified / fda approved, disposable sterile surgical rubber gloves size 7 inches made of natural rubber latex, powder free (polymer /silicon coated), without tear, properly folded in a paper free of holes, with acceptable quality level (aql) of 1.5 or less tensile strength as per en 455-2 should conform to is 13422isi marked / ce certified / fda approved (ce certification / fda approval for item is mandatory for importer firms, that cannot avail is standards, suction catheter, sterile. size: fg 5 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) should conform to is0 8836:2014, suction catheter, sterile. size: fg 6 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) should conform to is0 8836:2014, suction catheter, sterile. size: fg 8 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) should conform to is0 8836:2014, suction catheter, sterile. size: fg 10 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) should co
Tender For repair of bag house equipment in crmp- 1) cage repair( bending minor welding & painting), 2) cleaning and fixing of bags( opening the chamber, removing the venturies, taking out bags cleaning with and refixing) once in year, 3) cleaning of dust collecting hopper of bag house, 4) repair of dust hopper and its doors, 5) bag house screw conveyor body repair, 6) bag house screw conveyor hanger bearing with shaft changing, 7) bag house screw conveyor end bearing changing, 8) bag house screw conveyor coupling repairs, 9) bag house screw conveyor changing, 10) en masse conveyor drive sprocket changing, 11) en masse conveyor tail sprocket changing., 12) en masse conveyor drive chain fixing, 13) en masse conveyor links changing, 14) en masse conveyor drive unit coupling repair, 15) en masse conveyor drive chain rejointing in snap, 16) maintenance of rotary air locks (twice in a year), 17) bucket elevator belt rejointing in case of snap, 18) bucket elevator drive pulley changing, 19) bucket elevator boot pulley changing, 20) bucket elevator fallen buckets fixin, 21) pulse jet solenoid valves repair and maintenance, 22) drier maintenance in compressor house (4 driers), 23) maintenance of compressed air pipe line, 24) id fan casing removal and fixing back to faciltate for fan changing, 25) id fan casing cutting and fixing back during bearing changing, 26) id fan casing changing, 27) id fan casing repair work, 28) id fan suction duct patch work, 29) id fan delivery duct patch work, 30) to make arrangement for chimney cleaning on id fan delivery duct near chimney and duct opening and closing there.., 31) dust hopper gate replacement, 32) dust hopper vibrofeeder replacement, 33) dust hopper body repair patch work, 34) flexible hose to pulse jet replacement, 35) pulsing pipe changing, 36) pulsing pipe repair, 37) cyclone patch work, 38) flue gas duct leaks arresting patch works.
Tender For corrigendum : supply of supply of spares and consumables for sg tubes grit blasting. blasting hose 25 mm for grit blasting equipment pressure rating 10 bar , silicon bush red 6 x 13.5 x 30 mm for grit blasting equipment. , silicon bush red 6 x 13.5 x 60 mm for grit blasting equipment. , neoprene nozzle cap for suction for grit blasting equipment. , neoprene nozzle upper cap for grit blasting equipment. , cartridge filter 324 mm x 660 mm cellulose 21 sq. meter for grit blasting equipment. , nylon nozzle holder 19 mm for grit blasting equipment. , tungsten carbide nozzle with teflon sleeve for grit blasting equipment. , thompson valve 32 mm with 38mm nipple for grit blasting equipment. , oil seal set 16 idx30 odx10 w for grit blasting equipment, 1 set contains 40 nos.
Tender For e-bid for rate contract cum supply and empanelment of surgical items - blood administration set / blood transfusion set sharp and easy piercing spike suitable for blood bags and standard blood containers transparent cylindrical drip chamber with filter.filter size should be 200+20 micrometer. 150 cm long smooth kink resistant tubing efficient roller clamp to control and adjust the transfusion rate as per is 9824 (part 3):1996, suction catheter, sterile. size: fg 6 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 8 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile.size: fg 10 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 12 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 14 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment. length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile. size: fg 16 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment length 50 cm (min.) as per is0 8836:2014, suction catheter, sterile.size: fg 18 (for use in respiratory tract) soft, kink resistant tubing rounded open tip with lateral eye colour coded universal funnel connector for safe connection to standard suction equipment. length 50 cm (min.) as per is0 8836:2014, sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size 8 fg made of silicone elastomer bonded with latex should have hard plastic valve smooth distal end with smooth eyes for atraumatic intubation. symmetrical foley balloon balloon capacity 3- 5 ml as per is 11497 color coding marking to identify size. length, wall thickness and balloon capacity should be mentioned as per is 11497. specification for b,c,d,e,f,g should be mentioned as per is 11497 for particular size, sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size10 fg made of silicone elastomer bonded with latex should have hard plastic valve smooth distal end with smooth eyes for atraumatic intubation. symmetrical foley balloon balloon capacity 3- 5 ml as per is 11497 color coding marking to identify size length, wall thickness and balloon capacity should be mentioned as per is 11497. specification for b,c,d,e,f,g should be mentioned as per is 11497for particular size., sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size16 fg made of silicone elastomer bonded with latex should have hard plastic valve smooth distal end with smooth eyes for atraumatic intubation symmetrical foley balloon balloon capacity 30 1 ml should conform to is 11497 color coding marking to identify size. length, wall thickness and balloon capacity should be mentioned as per is 11497. specification for b,c,d,e,f,g should be mentioned as per is11497 for particular size, sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size18 fg. made of silicone elastomer bonded with latex. should have hard plastic valve. smooth distal end with s