Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For supply of ultrasound machine , digital tens unit , laser therapy unit , portable tens unit , deep freezer , reusable freezer ice blocks , gel pack with strap , physiotherapy suspension frame with couch and accessories or equivalent , physiotherapy treatment couch , examination couch stepper , physiotherapy equipment trolley , cryotherapy bath tub , station separator for three physiotherapy stations , three hundred and sixty degree shoulder wheel , yoga mat , foam roller , ankle and heel exerciser , cushions for physiotherapy positioning and support , resistance band set , half balance ball trainer , balance board , repair and servicing of existing ultrasound therapy machine , repair and servicing of existing shortwave diathermy machine , station name boads , main name board , equipment description boards , physiotherapy exercises boads , electric works * /bid number : gem/2026/b/7703772 + /dated: 30-06-2026 ' ' / bid document 1 / 27
Tender For providing of repair and overhauling service - repair of cooling cabinet (voltas chest freezer model: cf500l htd); voltas; yes; buyer premises
Tender For corrigendum : items - equipment accessories, abg machine ( as per model , make), 1. all card (as per req), 2. printing papers rolls (as per req), 3. cuvettes (as per req), 4. refill solution 100 ml (as per req), 5. controls, 6. syringe tips, 7. cleaning solution 100 ml, anesthesia machine ( as per model , make), 1. soda lime 5kg , 2. mask, 3. breathing circuits, 4. anesthesia agents, 5. bains circuit, 6. flow sensor, 7. oxygen sensor, 8. isoflurane inhaler 100ml, bloodbankrefrigerator ( as per model , make), 1. chart paper (as per req), 2. ink cartridge (as per req), 3. refrigerant gas, 4. oil filter, 5. air filter, defibrillator ( as per model , make), 1. pads, 2. jelly 100 gm, 3. paper, 4. leads, 5. battery, 6. bp cuff adult / neonation, 7. disposable electrodes, elisa reader washer ( as per model , make), 1. printing papers rolls (as per req), 2. cuvettes (as per req), 3. refill solution 100 ml (as per req), oxygen concentrator ( as per model , make), 1. o2 tubing (as per req), 2. face masks (as per req), suction machine ( as per model , make), 1. transparent cannula, 2. suction cannula, 3. holder, 4. filter, 5 jaar, 5. tube, x-ray machine ( as per model , make), 1. battery in hf, ventilator ( as per model , make), 1. disposable masks, 2. breathing circuits, 3. hme filter, 4. bacterial filter, 5. oxygen sensor, 6. flow sensor, 7. battery, microscope ( as per model , make), 1. immersion oil, deep freezer, walk in freezer, walk in cold room, walk in cold room, ice lined refrigerator ( as per model , make), 1. chart paper (as per req), 2. ink cartridge (as per req), 3. refrigerant gas, 4. oil filter, 5. air filter, 6. battery, usg machine ( as per model , make), 1. ups batteries, 1. jelly 100 gm, 2. thermal paper roll (as per requirement), autoclave ( as per model , make), 1. printer ribbon and rolls, 2. b & d test pack, 3. biological indicators, 4. water quality should be as per oem recommendations otherwise, 5 heating elements will be consumable., audiometer ( as per model , make), 1. ear tips, 2. electrodes, others items, multipara monitor lead ( as per model , make ), multipara monitor stand ( as per model , make ), multipara monitor prob ( as per model , make ), tabletop pulse oxymeter prob ( as per model , make ), tabletop pulse oxymeter adaptor ( as per model , make ), autoclave biological indicators tape ( as per model , make ), ecg machine lead ( as per model, make), ecg electrodes, nibp cuff (as per model , make ), silicone suction tube per meter, spo2 probe neonatal as per department equipment, spo2 probe pediatric as per department equipment, spo2 probe adult as per department equipment, stethoscope ( adult) dr. morepen, bpl, diamond
Tender For corrigendum : provn of receipt and dispatch office and deep freezer at 274 and water cooler and deep freezer at 402 and special repair to building no t-26 and provn of air conditioner at 205 and at tezu inder ge (p) lohitpur