Tender For purchase of equipments - purchase of equipment, 1. configuration design an 8-channel battery analyzer and its accessories 2. power 425 w3. voltage measuring range: 25 mv to 5 v, discharge minimum voltage: 0v or better, accuracy: 0.05% of fs4. current range: 0.5 ma to 6 a, accuracy: 0.05% of fs or better 5. power per channel output power: 30w, stability; +/- 0.1% of fs or better6. time rise time: 1ms (0~full range)7. frequency 10hz8. charge mode of operation: cc, cv, cccv, cp end conditions: voltage, current, relative time, capacity.9. discharge mode of operation: cc, cv, cp, cr, end conditions: voltage, current, test time, capacity, energy.10. pulse mode charge: cp mode, cc mode, discharge: cc mode, cp mode, min pulse width: 500ms, automated switch: automated switch from charge to discharge for each pulse end condition: voltage, relative time11. dcir support for the calculation of the point of the dcir12. cycle cycles: 1 65500 or better, steps: 250 or better, nested function: max three levels of loops13. protective function software, power-down data protection, user-defined safety (upper and lower) tolerance of current, voltage, and delay time14. channel features independent pairs of closed loops for the constant current source and constant-voltage source15. test reports and curves for analysis different types of curves created by software based on user definition. (voltage-time curve, current-time curve, capacity-voltage curve, loops times charge/discharge capacity curve, loops times charge/ discharge efficiency curve, etc.), data reports created by the software. comparison of the performance of the batteries tested in channels, both visually and statistically16. channels independent control17. ac input ac 220v 10% / 50hz 18. voltage and current testing sample 4 wire connecting 19. noise 85db20. data management mysql database21. communication means tcp/ip protocol22. data output excel, txt23. communication interface ethernet port24. number of channels per cabinet 825. accessories: 1. bi-potentiostat: electrochemical workstation or moduletechniques the system should be capable of running the rde / rrde technique simultaneously cyclic voltammetry (cv) with simulation/fitting programs linear sweep voltammetry (lsv) with stripping bulk electrolysis with coulometry (be) differential pulse voltammetry (dpv) with stripping normal pulse voltammetry (npv) with stripping tafel plot (tafel), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear polarization, corrosion current, etc. multi-current steps (istep) amperometric i-t curve (i-t) lifetime testing open circuit potential time (ocpt) chrono amperometry (ca) chrono coulometry (cc) chronopotentiometry with current ramp (cpcr) potentiometric stripping analysis (psa) auxiliary signal measurement channel ir compensation external potential input galvanostatic charge discharge single/multiple cycle -chrono potentiometry (cp) with potential limits, polarity by potential or time, no. of cycles etc. voltage vs current density curves single or multiple potential steps with charge limits, single or multiple current steps, mixed voltage/current control using macro. i-v measurements, i max, pmax, fill factor, etc.impedance ac impedance (imp) 10 hz to 3mhz impedance time (impt) (mott-schottky) impedance potential (impe) impedance simulator with fitting open circuit potential time (ocpt)hardware specification of bi-potentiostat workstation/ module: potentiostat / galvanostat module, 2- or 3- or 4-electrode configuration maximum potential: 10v, maximum current: 250 ma peak or better and 2 amps with +/-25 volts for higher current measurement. compliance voltage: > 13v or better, potentiostat rise time: 300 ns or better galvanostat applied current range: 3na to +/- 100ma or better and upto 2 amps applied current accuracy: 20 pa or better input bias current: 1 pa or better cv and lsv scan rate: 0.000001 to 10,000 v/s. ca and cc pulse width: 0.0001 to 1000 sec imp frequency: 0.00001 t
Tender For tender for supply, installation, training and commissioning of particle size (dynamic light scattering) and zeta potential analyzer (electrophoretic light scattering) with three years onsite all inclusives comprehensive warranty period - tender for supply, installation, training and commissioning of “particle size (dynamic light scattering) and zeta potential analyzer (electrophoretic light scattering)” with three years on-site all inclusives comprehensive warranty period as per the specifications attached in section - 3.
Tender For purchase of sports exercise physiology lab equipments - cardiopulmonary exercise testing system (including treadmill & cycle ergometer) (2 years warranty)(pac), portable telemetric metabolic analyzer for field and laboratory use.metabolic analyzer portable telemetric system for metabolic analysis should have the following specifications:designlatest generation, single body - weather and dust proof to suit our requirement of tough testing conditions. it should operate in standalone, holter and direct connection to pc modes.weight on subjectless than 1 kg including battery and ergonomically designed multi-size adjustable harnesstesting capabilitypulmonary gas exchange (vo2, vco2), vo2 max, sub-max vo2, thresholds (at, rcp), heartrate with hr belt, resting energy expenditure (ree, rmr), indirect calorimetry w/ face mask, substrates analysis (rq, %fat, %pro, %cho)analysis method breath by breathmotion sensorsinbuilt gps, altimeter, accelerometer (3d + 8g range), gyroscope (3d + 2000 o/s range) andmagnetometer/compass (3d + 1000 t range)wireless connectivitywireless data transmission: bluetooth 2.1 + edr class ii (range >900 meters line-of-sight)connectivityusb, audio, heart rate (aux), wireless device interface (bluetooth for integration with compatible optional peripherals like spo2, ecg etc.)data storagestorage: 512 mb flash > 2,000,000 breathsadditional: sd-hc card 32gb/fat32 - internal slot user accessibledisplay lcd: 3.5 lcd transflective colour - high visibility with led-backlit tfttouch-screen: resistive technology, that allows gloves and wet fingersanalysersoxygen: gfc 0-25% range, lifespan approximately 12 months (very easily user replaceable) response time 120 mscarbon-dioxide: digital ndir 0-10% range, response time 100 msbarometer: range -600 to +5500mflowmeter: bi-directional digital turbine ventilation range 0 to 300 l/min powerbattery: rechargeable li-ion smart battery w/ lcd charge status indicator. 2 packs backup battery: embedded to allow main battery replacement during testing without loss of datamain: 100-240v ac/dc adapter, for direct/main power supply and battery charging. essential accessories / consumablesthe system should be supplied with a compatible treadmill and ergo cycle as per specs below. list of standard items supplied and details of consumables including o2 sensor with their life span should be provided. a compatible laptop pc, colour deskjet printer, 3 litre calibration syringe & calibration gas mixture cylinder with regulator should be supplied with the systemquality assurancemust have european ce, us fda and iso certifications. treadmill running machine with user terminal (display & keyboard) stand- alone and remote control with cpet via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 300 kg (660 lbs) speed range: 0-25 km/h elevation: 0 to 28% reverse belt rotation motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v - belt, very quiet operation safety arch should be provided with harness of 5(five) different sizes (small to large) safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10 to +40 degrees c, humidity 30 to 70% display: touch screen display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gasanalyzer as per standard and custom exercise protocols different programs para control software for pc must have ce certificationergo cycle functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-assisted seat adjustment easy to control and calibrate. can be co