Web Analytics Made Easy - StatCounter

Blood Pressure Equipment Tenders

Get complete information related to latest Blood Pressure Equipment Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Blood Pressure Equipment Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Blood Pressure Equipment Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45532877 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For e-tender for procurement of some consumable items for two years from the date of award of contract (aoc)- disposable surgeons full wrap around gown specification: the products should be eo sterilized & ready to use, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 18g - length-15cm/10cm/8cm/ 6cm/4cm) with seldinger technique, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 22g - length-15cm/10cm/8cm/6cm/4cm) with seldinger technique, blood pressure equipment, sphygmomanometer, digital with pulse recording and 100 reading memory, blood transfusion set, sterile, disposable • medical grade non toxic and dehp free tubing with 200 micron filter • clear, transparent, flexible molded drip chambers with fix fluid filters and bacteria retention air vent transparent spike for easy piercing • efficient roller control for better flow control • molded “bulb type” injection site for extra medication • approximately 20 drops, l ml dw • sterilization by eto or more advance process. leur lock., bipap mask with bronchoscopy port along with accessories detachable & autoclavable vented / non vented swivel connector., blood cardioplegia device - adult - heat exchanger pleatal type. priming volume of heat exchanger : <30 ml . integrated heat exchanger with bubble trap. assemble with class vi implant tested tubing. high cooling eficiency. eassy set up and priming. outlet comnnection 1/4" built in bridge for choice of 100 % blood and 100 % cardiopledgia solution delivery., blower mister kit : comfortable hand grip with a 6.5" (16.5 cm) malleable stainless steel shaft for ease of positioning near the surgical site.the soft; silicon tip contains a plastic tube which carries saline to the tip ., burret set (100ml), c-arm cover 2 part materials-plastic, sterile pack, ready to use., catheter mount, collapseble catheter mount with bronchoscopy and suction port, cervical spinal locking plate assorted size with required screw, material – titanium, close suction with non returnable valve and terbojet clining system. sizes 10,12,14 fr., connector - straight assorted sizes - pvc material, sterile pack, coronary shunts assorted size : bevelled ultra-soft tip , obstruction -free flow path , large atraumatic sealing surface & flexible shaft., cvc3 fr. with anti kinking nitinol guide wire (paediatric)- 6cm/l0cm/15 cm with long shelf life >5 years. thermosensitive polyurethane double lumen paediatric cvc with accessories., cvp transducer : integrated unit for clinical accuracy. dual mode of flushing controlled squeeze and snap-tab. completely transparent for easy priming and debubbling with flushing of 3 cc / hr or without flush. easy zeroing. standard closed loop sampling kit / double. [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], cvp transducer compatible with arterial pulse contour monitor (disposable single use) [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], disposable sterile full gown with eye protection sterile disposable prepackaged, disposable ventilator circuit with single water trap. should be tidel volume range from 200 ml to 1500 ml. should be minimal deade space 55 ml. medical grade pe. connector 15/22 mm m/f for y piece, connector 15/22 mm m/f for ett & mask. standard length . 6ft. or expandable length., dome kit with flushing system. • should be single line monitoring dome. • should be measure invasive pressure., digital foetal doppler, eye drape • sheet size: 80 x 75 cm - 90 x 75 cm • adhesive area: 9 x 7 cm with 6 eye lid holders • drainage pouch of transparent pe film • eto (eo) sterile, face mask , disposable ,should be manufactured from non woven poly prop fabric ,should be 3 ply construction,should have high bacterial filtration efficiency ,should be cor ners, length of string should be 40 cmheat sealed to keep 3 layers together ,standard size 17.5 x 9 cm, colour green / blue ,th

Central Government/Public Sector

CTN :45532880 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For e-tender for procurement of some consumable items for two years from the date of award of contract (aoc)- disposable surgeons full wrap around gown specification: the products should be eo sterilized & ready to use, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 18g - length-15cm/10cm/8cm/ 6cm/4cm) with seldinger technique, arterial lines : polyethylene/ polyeurathene arterial lines (singlelumen 22g - length-15cm/10cm/8cm/6cm/4cm) with seldinger technique, blood pressure equipment, sphygmomanometer, digital with pulse recording and 100 reading memory, blood transfusion set, sterile, disposable • medical grade non toxic and dehp free tubing with 200 micron filter • clear, transparent, flexible molded drip chambers with fix fluid filters and bacteria retention air vent transparent spike for easy piercing • efficient roller control for better flow control • molded “bulb type” injection site for extra medication • approximately 20 drops, l ml dw • sterilization by eto or more advance process. leur lock., bipap mask with bronchoscopy port along with accessories detachable & autoclavable vented / non vented swivel connector., blood cardioplegia device - adult - heat exchanger pleatal type. priming volume of heat exchanger : <30 ml . integrated heat exchanger with bubble trap. assemble with class vi implant tested tubing. high cooling eficiency. eassy set up and priming. outlet comnnection 1/4" built in bridge for choice of 100 % blood and 100 % cardiopledgia solution delivery., blower mister kit : comfortable hand grip with a 6.5" (16.5 cm) malleable stainless steel shaft for ease of positioning near the surgical site.the soft; silicon tip contains a plastic tube which carries saline to the tip ., burret set (100ml), c-arm cover 2 part materials-plastic, sterile pack, ready to use., catheter mount, collapseble catheter mount with bronchoscopy and suction port, cervical spinal locking plate assorted size with required screw, material – titanium, close suction with non returnable valve and terbojet clining system. sizes 10,12,14 fr., connector - straight assorted sizes - pvc material, sterile pack, coronary shunts assorted size : bevelled ultra-soft tip , obstruction -free flow path , large atraumatic sealing surface & flexible shaft., cvc3 fr. with anti kinking nitinol guide wire (paediatric)- 6cm/l0cm/15 cm with long shelf life >5 years. thermosensitive polyurethane double lumen paediatric cvc with accessories., cvp transducer : integrated unit for clinical accuracy. dual mode of flushing controlled squeeze and snap-tab. completely transparent for easy priming and debubbling with flushing of 3 cc / hr or without flush. easy zeroing. standard closed loop sampling kit / double. [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], cvp transducer compatible with arterial pulse contour monitor (disposable single use) [note : compatible cable, cvp/ibp transducer clamp (reusable) will be supplied at free of cost ], disposable sterile full gown with eye protection sterile disposable prepackaged, disposable ventilator circuit with single water trap. should be tidel volume range from 200 ml to 1500 ml. should be minimal deade space 55 ml. medical grade pe. connector 15/22 mm m/f for y piece, connector 15/22 mm m/f for ett & mask. standard length . 6ft. or expandable length., dome kit with flushing system. • should be single line monitoring dome. • should be measure invasive pressure., digital foetal doppler, eye drape • sheet size: 80 x 75 cm - 90 x 75 cm • adhesive area: 9 x 7 cm with 6 eye lid holders • drainage pouch of transparent pe film • eto (eo) sterile, face mask , disposable ,should be manufactured from non woven poly prop fabric ,should be 3 ply construction,should have high bacterial filtration efficiency ,should be cor ners, length of string should be 40 cmheat sealed to keep 3 layers together ,standard size 17.5 x 9 cm, colour green / blue ,th

Central Government/Public Sector

CTN :45160636 Due date: 12 Jun, 202612 Jun, 2026 NA
Tender For re e-tender for procurement of consumable items for two years from the date of award of contract (aoc) - adhesive (copolymer) based silk tape, non-elastic tape with strong tensile strength, 1.25 cm (minimum.) x9m (minimum).adhesive (copolymer) based silk tape, non-elastic tape with strong tensile strength, 2.50 cm (minimum) x 9m (minimum).adhesive (copolymer) based silk tape, non-elastic tape with strong tensile strength, 5.00 cm (minimum) x 9m (minimum).blood pressure equipment, anaroid type (sphygmomanometer, aneroid type)bone cement 40 gm pack (regular viscosity & low viscosity) with gentamycin: methyl methacrylate / methyl acrylate copolymer blend sterilised using ethylene oxide gasbone currete (small/medium/large)cannula, aortic arch cannula - neonatal: straight tip, soft flexible bodyenables easy poioning yet resist kinking, 8fr (2.7 mm), 1/4 connector, ce /usfda certified.cannula, vessel cannula: clear body, soft plastic tip, female luer lock. size: 3 mm blunt tipcatheter, fogarty arterial embolectomy catheters size 3f -7fcannula, cardiopledigia cannula (neontal): radiopaque tips attached to clear bodies, left heart venting long tip and standard introducer. size: 14 ga (7cannula, cardiopledigia cannula (paediatric): radiopaque tips attached to clear bodies with separate vent lines, include aortic root pressure monitoring and left heart venting. size: 16 ga (5 fr.)cover glass 0.16 to 0.19 mm thick, rectangular, sizes [22 x 50 or 25 x 50 ]cover glass 0.16 to 0.19 mm thick, square of 5 sizes [7/8" or 4/5" or 3/4" or 11/4" or 1?"]diagnostic glide catheter for abdominal angiographiy size: 5fr & 6 fr. . should be hydrophilic polymer coated catheter. should be soft tip is installed on distal end.. should be available different shape type.diagnostic glide catheter for cerebral angiographiy size: 5fr & 6 fr. should be hydrophilic polymer coated catheter. should be soft tip is installed on distal end.. should be available different shape type.disposable needles 18gcannula, long femoral arterial cannula of sizes (15 fr/17 fr/19 fri 21 fr/ 23 fr) or (16 fr/18 fri 20 fri 22 fri 24 fr) with multiple side holes, wire reinforced and kink resistant, thin walled, smooth tip with radio opaque marker for easy percutaneous insertion along with insertion kit containing dilator set of various sizes, two trip guide wires (0.038") 100 cm & 150 cm in length, 18g puncture needle & mini scalpes.triple lumen central venous catheter, 7fr/7.5fr (14/16/18/18g), made up of polyurethane material, length 15/20 cm. with nitinol guide wire, dilator, scalpel, (sutureless fixation device, 18g valve needle having port.)combined spinal epidural anaesthesia kit- needle through needle technique, locking mechanism for securing spinal needle. spinal needle-pencil pointed and it allows 360 degree rotation for spread of drugs. touhy needle, 18g epidural catheter 100 ± 10 cm. (made up of polyurethane material or better material, tapering tip), epidural filter, lor syringe & locking device.combined spinal epidural system: 1. should have 18g tuohy needle of 80mm length and graduations with internal stylet and optional snap on wings. 2. should contain 25g/27g pencil point spinal needle of 118 mm length with internal stylet. 3. should have a 10ml epirural 'loss of resistance' syringe. 4. should have an 20g peribax epidural catheter with a smooth closed tip, distal tip mark. 5. should have a catheter connector with a flat profile for increased patient compfort. 6. should have a flat filter with a 0.22µm. examination lampforceps, artery, kochers box joint 15 cmforceps, artery, mosquito, straight 12.5 cmforceps, artery, moynihans, straight, box joint 16 cmforceps, dissecting, toothed end 15 cmforceps, dissecting, toothed end bonney's 18 cmforceps, dissecting, round serrated tips, 178 mmforceps, rat tooth retrieval forceps 4fr, 65 cmforceps, rat tooth retrieval forceps 3.3fr 4fr, 115 cm / 210 cmforceps, sponge holding, s.j. straight, 23.5 cmforceps, s
 Loading, Please wait...

Connect us via What's Up