Get complete information related to latest Blower Fan Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Blower Fan Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Blower Fan Tenders.
Tender For corrigendum : supply of repair and preventive maintenance of dg set ranchi oa - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blowerfan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva //bid details 2 / 35
Tender For corrigendum : providing of repair maintenance of dg set hazaribag - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blowerfan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
Tender For corrigendum : providing of repair and maintenance of dg set under daltonganj - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blowerfan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
Tender For double inlet centrifugal blowerfan complete with mounting brackets suitable for 415v, 3 phase, 50 hz supply conforming to rcf specification no. edts-331(rev-'a') corrigendum 1. [ warranty period: 30 months after the date of delivery ] ]
Tender For procurement of different spares for chinese make elevators under emiph-i, sgtpp. - procurement of different spares for chinese make elevators under emiph-i, sgtpp., limit switch,car door contact,type:ds131 for seec express elevator 1no, ue-230vac/110vdc, ie-2a/0.5a, ui/ith-500v/10a, ip20, transparent enclosure ( please follow additional data: model: s3-1370b: normal close make: beto or model: ndox 41k ), shoe liner car guide shoe liners # shoe liner(car guide shoe liners) 1set/4pcs e.c.e ( please follow additional data: guide shoe; moc: nylon; dimension: 150mm x 30mm x 30mm (as per sample) ), landing door shoe for ece make elevator acme make: fermatorrn ( please follow additional data: door chanel shoe, dimension: 56mm x 40mm; thickness: 2mm with both side rubber. (as per sample) ), v belt, a 1180 ( please follow additional data: belt, qxpz 1180 cogged raw edge epdm wedge belt, fenner ), belt, timing, 3600-s8m-15, htd for seec express elevator car door type- high torque drive (htd) timing belt, length-3600mm, width-15mm, belt thickness- 5.6mm, tooth height-3.4mm, tooth pitch-8mm, material-neoprene rubber withfiber glass core., reed switch ( please follow additional data: for elevator (as per sample), sichuan express elevator co. ltd. ), vfd for car door astar s2 20p4a2 power 0.4 kw,i/p 220vac,50/60 hz,5.3 a,o/p 220vac,0-50 hz,3a.0.6 kva, oil pot(at feeder on car top) ( as per sample ), hooter industrial 230v ( with power back-up for sichuan express elevator co. ltd. ), rotary blowerfan for elevator # ( car roof fan, crossflow fan, model: zqf-330 200, 230v ac, 25w, 1270/1350 rpm, 340/360 m3/hr ; make: ningbo grand fans co. ltd. ), switch,red,1no,call push button dia-37mm for seec express elevator 24vdc, illuminated, colour- red, flush mount ( landing: up/down-25 nos., car: open-close-15 (each); 1-5: 10 (each); 6-9: 5(each) ), board, lop,intl 2000-dv/v1 for seec express elevator sichuan express elevator co. ltd., door sensor (lambada),model:ms720 ( make- t l jones or equivalent ), rope oil for elevator rope usha wrl-60 usha martin, brake coil for hoist,230v ac ( please follow additional data: brake coil for sichuan express elevator co. ltd., coil voltage: 110v dc (as per sample) ), dynamic braking unit,cdbr-4030b,400 v yaskawa vvvf drive cimr f7a4030,30 kwfor s/r vvvf drive, expansion pcb for elevator intl 2000-ex sichuan express elevator co. ltd.
Tender For tender for supply of rate contract for vibration monitoring - gear box of aeroderivative gt rating 4.2mw including gb driven main lube oil pump and main seal oil pump , gb driven main lube-oil pump of aeroderivative gt rating 2.7mw) , centrifugal pump blowerfan including motor up to 20kw , centrifugal pump blowerfan including motor from 20 to 50kw , centrifugal pump blowerfan including motor more than 50kw , diesel engine including comp rating up to 50kw , diesel engine including pump from 200 to 500kw , diesel engine including alternator from 500 to 1500kw , reciprocating pump/comp including motor upto 50kw , reciprocating pump/comp including motor more 50kw
Tender For running maintenance of plc system - running preventive and breakdown maintenance of plc control system with electrical drives all control and instrumentation system of ash handling , replacement new erection of impulse line , replacement new erection of instrument fitting adopter nut tails elbow connector etc , overhauling b 501 and b 601 ss cock valve , overhauling repairing of junction boxes , servicing recalibration erection of fuzi yokogava rosemount etc transmitters , overhauling and recalibration new erection of digital indicators , overhauling and recalibration erection of flow meter conductivity meter , complete overhauling erection of level switches , replacement of pressure switch gauge vibration switch , removal testing erection commissioning calibration of temp gauges switches thermocouple , replacement erection overhauling cleaning of union isolating valveforged body valve , blowing of tapping points of different pressure transmitters switches , fabrication repairing of instruments plateform , laying patrolling of instrumentation cable , servicing and maintenance of air conditioner , cleaning of control room plc system , repairing of ups , service replacement of faulty butterfly valves along with act , servicing replacement of faulty diaphragm type valves , changing spindle gland of root valves , cleaning blowing by air of impulse lines , attend leakage from steam water air line , replace gauges switches of pressure temp , testing caliberation of pressure gauges , testing calibration of pressure switches , testing calibration of temp gauges , testing calibration of temp switches , replacement of thermocouples , cleaning servicing of terminal block in compressor house swas system , changing of ss root valves , servicing of 10mm hp lp 3way manifold valves , replace of 10mm hp lp 3way mfold valves , removal choking replace of impulse line , erection replacement of pvc armored compensate cable , replacement of universal digital indicator , servicing replacement of faulty 4way valve with actuator , replacement remounting of smps 24 v dc , dismantling replacement of combination timerof compressor , servicing of sampling cooler dhx18 sco2 , servicing of sampling cooler dhx12 sco2 , servicing of sampling cooler dhx06 sco1 , miscellaneous mechanical febrication , maintenance of actuator of butterfly valve , maintenance and upkeep of terminal box of motor of actuators in cw pump , maintenance re erection of butterfly valve actuator motor , revisioning and upkeep of marp dcs panel , revisioning testing of various type of switches of local control panel , maintenance revisioning upkeep and testing of 415 v power supply module , maintenance upkeep and repair of junction box of butterfly valve , servicing of mov motors actuators and limit switch assembly , checking cleaning and cable dressing mov motor , overhauling cleaning reconditioning of various size batteries , load test once in six months for various size battery of ups installed for 5x200mw , replacement of damaged switches mcb in acdb panel , cleaning painting of the wooden battery stands , maintenance of window type split type ac , gas charging of ac , rewinding of burnt fan motor
Tender For corrigendum : providing of repair and overhauling service - forklifts (v2) as per is 6765:2003 and is 10517; defect rectification of ventilation blowerfan motor onboard icgs c448 against dl sl l 071; no; buyer premises,repair and overhauling service - forklifts (v2) as per is 6765:2003 and is 10517; defect rectification of micro oven onboard icgs c448 against dl sl l 072; no; buyer premises,repair and overhauling service - forklifts (v2) as per is 6765:2003 and is 10517; defect rectification of 230v tube light illumination onboard icgs c448 against dl sl l 073; no; buyer premises
Tender For bid to ras supply of replacement of rotary compressor , replacement of indoor blowerfan motor , replacement of outdoor unit motor , replacement of pcb control unit , carrying out leak test and gas charging , shifting and reinstallation of outdoor units , sf 0.5 inch copper refrigerant pipe , sf 0.25 inch copper refrigerant pipe