Web Analytics Made Easy - StatCounter

Blower Fan Tenders

Get complete information related to latest Blower Fan Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Blower Fan Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Blower Fan Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45713858 Due date: 18 Jul, 202618 Jul, 2026 25.00 Lacs
Tender For repair maintenance of various types of summer appliances and other connected items at af station jammu and kaluchak under ge (af) jammu - repair to split ac and window ac, supply of labour only for attending and rectification of daily complaints for day to day maintenance and servicing for split ac/window ac /hot & cold air conditioner/dual inverter air conditioners/flame proof ac of any capacity and make installed in various locations of 23 wing af jammu and 256 su kaluchak (excluding sundays and holidays) with high skilled refrigerator mechanic and helper including detecting fault of split/window air conditioner complain and servicing all unserviceable parts for split/window ac and replacement of u/s parts & repair of all necessary items and handed over to user for serviceable condition within 24 hours for minor faults and within 48 hours for major faults all as specified and direted by engineer in charge.note: (a) contractor has to employ highly skilld refrigerator mechanic with helper and necessary t&p for attending day to day complaints of ref and ac failing which recovery shall be made at two times of quoted rate. (b) rate quoted shall be inclusive of transport from af station to work shop & back shifting within permises.( c) any parts shall be replaced and paid separately as "supply only " against relevant item (s) of this schedule. , m&l for shifting of split type ac/ window type ac capacity upto 2 ton , including submain/point wiring all electrical items and drilling, making good on surface of pcc concreting, white cement plastering and all necessary items and transporting complete one location to other location in 23 wing area and 256 su kaluchak area replacing unserviceable parts and handing over the machine/ equipment in serviceable condition to the user including fixing to new location all as specified and directed by engineer-in-charge., supply only the following items to incorporate against repairable summer appliances window / split type acs against relevant items no 2.00 and 3.00 here-in- before: -, blower motor complete suitable for window type ac upto 2.0 ton all as specified and directed by engr-in-charge., indicator suitable for window type ac up to 2 tonall as specified and direted by engineer in charge., thermostat switch suitable for window type ac up to 2 tonall as specified and direted by engineer in charge., control knob suitable for thermostat switch and selector switch of window type ac up to 2 tonall as specified and direted by engineer in charge., selector switch suitable for window type ac up to 2 ton all as specified and direted by engineer in charge., relay along with box suitable for window type ac upto 2 ton all as specified and direted by engineer in charge., plastic air filter suitable for window ac upto 2 tr. make- voltas/ bluestar/ lg/ samsung/ as on site., outer unit condenser fan motor suitable for window type ac up to 2 ton. make- voltas/ bluestar/ lg/ samsung/ as on site., fan for outer unit condenser motor suitable for window type ac up to 2 ton. make- voltas/ bluestar/ lg/ samsung/ as on site., front grill as per existing suitable for window type ac upto 2 ton.make- voltas/ bluestar/ lg/ samsung/ as on site., plastic air filter suitable for split ac indoor unit ac upto 2 tr. make- voltas/ bluestar/ lg/ samsung/ as on site., s&f power control board ( pcb ) for window type /split ac up to 2 ton . make- voltas/ bluestar/ lg/ samsung/ as on site., s&f power control board ( pcb ) for split ac indoor unit dual inverter/hot and cold ac up to 2 ton . make- voltas/ bluestar/ lg/ samsung/ as on site., s&f power control board ( pcb ) for split ac out door unit dual inverter/hot and cold ac up to 2 ton . make- voltas/ bluestar/ lg/ samsung/ as on site., wiring kit suitable for split ac and window type ac upto 2 ton., condenser fan motor complete with fan suitable for out door unit of split type air conditioner upto 2 ton. make- voltas/ bluestar/ lg/ samsung/ as

Central Government/Public Sector

CTN :45713851 Due date: 25 Jul, 202625 Jul, 2026 55.00 Lacs
Tender For repair/maint of air cooled ac plants, chiller, condenser pump, hot water boiler, ahu, water colled ac plants, motor, hwg and ahu alongwith connected items at akash complex/tech area at dappar under age(i) dappar - material and labour for servicing / cleaning of air cooled ac plants of 50 tr capacity, chiller unit, cleaning and washing of cooling coil with fins using a chemical c-shine (alkaline coil cleaner and brightener) and testing the unit (once in a three months) complete all as specified and as directed by engineer-in-charge. location :- akash air cooled ac plants(once in a three months), material and labour for descaling of complete condenser units for central/ package type ac plants of condenser unit of water cooled ac plantac plant upt to 40 tr capacities by means of adding descaling chemical solution (hcl) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and refixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc. to entire satisfaction of engineer-in-charge complete all as specified and as directed by engineer-in-charge. location :- old, 3ac igloo ac plant and new ac plant (once in a three months), material and labour for cleaning of cooling tower existing size, water basin and makeup tank with the help of chemical and nylon brush, removing and refixing of pvc finches after washing, cleaning of condenser pipe line ( inlet and outlet) including painting of out side of cooling tower with inlet and outlet pipe line with one coat synthetic enamel paint of colour approved by engineer in charge and inside painting of water tank of cooling tower using water proof black japan paint one coat including changing of unserviceable pvc guard, water distibutor, pvc pipe, and all connected minor items of up to 100 tr capacity of the ac plants at different locations complete all as specified and as directed. location :- old and new ac plant, material and labour for servicing of cooling coils and air filters of ahus intalled at air conditioning plant by removing air filters and fixing after cleaning with air blower and water and cleaning agent , cleaning of cooling coilwith wire brush and air blower and water spray pump after spraying scale gun or equivalant chemical suitable for aluminium fins and straighting the fins of cooling coil by using suitable brush for any capacity of ahu complete all as specified and as directed by engineer-in-charge. locaton :- new ac plant, old ac plant , 3 ac igloo ac and akash ac plants akash, material and labour for servicing / cleaning and testing of electrically operated pan type humidifier capacity 9 kw alongwith all necessary items fitting and all suitable / all necessary electrical wiring from electrical panle to humidifier complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in cold water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in hot water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing , cleaning , and greasing , chiller , hwg pumps , ahu and ct motors alongwith all necessary minor items/ fitting i.e bearing , star coupling , screws , nuts and bolts etc complete all as specified and as directed by engineer-in-charge. location :- new ac plant , old ac plant and air coole

Central Government And Public Sector

CTN :45615691 Due date: 02 Jul, 202602 Jul, 2026 5.65 Lacs
Tender For corrigendum : supply of repair and preventive maintenance of dg set ranchi oa - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva //bid details 2 / 35

Central Government And Public Sector

CTN :45617559 Due date: 03 Jul, 202603 Jul, 2026 5.63 Lacs
Tender For corrigendum : providing of repair maintenance of dg set hazaribag - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva

Central Government And Public Sector

CTN :45617729 Due date: 03 Jul, 202603 Jul, 2026 5.66 Lacs
Tender For corrigendum : providing of repair and maintenance of dg set under daltonganj - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva

corporations/Associations/Others

CTN :45557566 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For corrigendum : tender for supply of bearing 189 - bearing 6208 zz , bearing 6204 , bearing no.1210k with sleeve h 210 , bearing 2315k with adopter sleeve , bearing no 6309 , bearing 2305 , bearing 6413 , bearing no. 6408 , bearing 6204zz , bearing 6206zz , bearing 6304zz , bearing 2201 , bearing 6202 , bearing 6203 , bearing 6312zz , bearing 6312 c3 , bearing 111307 for blower fan , bearing 6004zz , bearing no. 6201 , bearing 6202 zz , bearing 6204-c-zz , bearing 6205c-zz , bearing no. 6208 , bearing no. 6211 , bearing no.6212 , bearing no.6213 , bearing no. 6305 , bearing no. 6311 , bearing no. 6312 , bearing no 6313zz c3 , bearing no. 6317c3 , bearing no. 6318 , bearing no. 6321 , roller bearing no. n317 , bearing no. nu319 , bearing no. nu-321 , bearing no. nu-318 , bearing 6311 , brg nu 321 c3 , brg no. 6318 , brg no. nu 320 , bearing no. klm 603049 & 603011

CTN :45728130 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For double inlet centrifugal blower fan complete with mounting brackets suitable for 415v, 3 phase, 50 hz supply conforming to rcf specification no. edts-331(rev-'a') corrigendum 1. [ warranty period: 30 months after the date of delivery ] ]

CTN :45719794 Due date: 20 Jul, 202620 Jul, 2026 19.43 Lacs
Tender For procurement of different spares for chinese make elevators under emiph-i, sgtpp. - procurement of different spares for chinese make elevators under emiph-i, sgtpp., limit switch,car door contact,type:ds131 for seec express elevator 1no, ue-230vac/110vdc, ie-2a/0.5a, ui/ith-500v/10a, ip20, transparent enclosure ( please follow additional data: model: s3-1370b: normal close make: beto or model: ndox 41k ), shoe liner car guide shoe liners # shoe liner(car guide shoe liners) 1set/4pcs e.c.e ( please follow additional data: guide shoe; moc: nylon; dimension: 150mm x 30mm x 30mm (as per sample) ), landing door shoe for ece make elevator acme make: fermatorrn ( please follow additional data: door chanel shoe, dimension: 56mm x 40mm; thickness: 2mm with both side rubber. (as per sample) ), v belt, a 1180 ( please follow additional data: belt, qxpz 1180 cogged raw edge epdm wedge belt, fenner ), belt, timing, 3600-s8m-15, htd for seec express elevator car door type- high torque drive (htd) timing belt, length-3600mm, width-15mm, belt thickness- 5.6mm, tooth height-3.4mm, tooth pitch-8mm, material-neoprene rubber withfiber glass core., reed switch ( please follow additional data: for elevator (as per sample), sichuan express elevator co. ltd. ), vfd for car door astar s2 20p4a2 power 0.4 kw,i/p 220vac,50/60 hz,5.3 a,o/p 220vac,0-50 hz,3a.0.6 kva, oil pot(at feeder on car top) ( as per sample ), hooter industrial 230v ( with power back-up for sichuan express elevator co. ltd. ), rotary blower fan for elevator # ( car roof fan, crossflow fan, model: zqf-330 200, 230v ac, 25w, 1270/1350 rpm, 340/360 m3/hr ; make: ningbo grand fans co. ltd. ), switch,red,1no,call push button dia-37mm for seec express elevator 24vdc, illuminated, colour- red, flush mount ( landing: up/down-25 nos., car: open-close-15 (each); 1-5: 10 (each); 6-9: 5(each) ), board, lop,intl 2000-dv/v1 for seec express elevator sichuan express elevator co. ltd., door sensor (lambada),model:ms720 ( make- t l jones or equivalent ), rope oil for elevator rope usha wrl-60 usha martin, brake coil for hoist,230v ac ( please follow additional data: brake coil for sichuan express elevator co. ltd., coil voltage: 110v dc (as per sample) ), dynamic braking unit,cdbr-4030b,400 v yaskawa vvvf drive cimr f7a4030,30 kwfor s/r vvvf drive, expansion pcb for elevator intl 2000-ex sichuan express elevator co. ltd.

CTN :45712855 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For tender for supply of rate contract for vibration monitoring - gear box of aeroderivative gt rating 4.2mw including gb driven main lube oil pump and main seal oil pump , gb driven main lube-oil pump of aeroderivative gt rating 2.7mw) , centrifugal pump blower fan including motor up to 20kw , centrifugal pump blower fan including motor from 20 to 50kw , centrifugal pump blower fan including motor more than 50kw , diesel engine including comp rating up to 50kw , diesel engine including pump from 200 to 500kw , diesel engine including alternator from 500 to 1500kw , reciprocating pump/comp including motor upto 50kw , reciprocating pump/comp including motor more 50kw

Central Government And Public Sector

CTN :45592924 Due date: 01 Jul, 202601 Jul, 2026 3.73 Lacs
Tender For bid to ras supply of replacement of rotary compressor , replacement of indoor blower fan motor , replacement of outdoor unit motor , replacement of pcb control unit , carrying out leak test and gas charging , shifting and reinstallation of outdoor units , sf 0.5 inch copper refrigerant pipe , sf 0.25 inch copper refrigerant pipe
 Loading, Please wait...

Connect us via What's Up