Get complete information related to latest Bocb Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bocb Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bocb Repair Tenders.
Tender For supply of 20 kva ups system with battery for mrpl project : : - 20 kva 110 v 50 hz ac ups system with ni cd battery battery charger acdb all accessories for 30 min backup time , sapre power thyristors transistors igbt igct , spare control cards , spare power supply cards , spare power fuses , spare control fuses mcb , spare indicating lamps , spare indicating lamps covers , spare blocker diode
Tender For supply of totally closed metal clad stove enameled tripple pole fuse , totally closed metal clad stove enameled tripple pole fuse switch , tpn switch fuse unit in sheet steel enclosure with hrc fuses fa-c 63a tpn , tpn switch fuse unit in sheet steel enclosure with hrc fuses 100a tpn , tpn switch fuse unit in sheet steel enclosure with hrc fuses type - fn 250 amps , tpn switch fuse unit in sheet steel enclosure with hrc fuse type-fn 400 , 200a, 415v ac,triple pole and neutral type rewirable porcelein fuse switch , totally closed metal clad stove enameled tripple pole fuse switch unit with , totally closed metal clad rebu st construction stove enameled tripple pole fuse , tpn switch fuse unit in sheet steel enclosure with hrc fuse 400amps 500 volt
Tender For corrigendum : supply of 25 amps, 500 volt ac, nh knife blade fuse (din type), size nh000 with caharacteristic:-gg/gl, breaking capacity 120 ka. confirming to is: 13703/iec 60269-2, suitable for kva transformer 415 output side hrc fuses in underslung hv power panel. accepted makes: siba/efen/ferraz/eti/siemens/bussmann/schneider/ge/l&t only as per item no. 7,8,9 of bom in annexure-a of edts 355 edts, rev-1.
Tender For corrigendum : supply of 16 amps, 500 volt ac, nh knife blade fuse (din type), size nh000 with characteristic:-gg/gl, breaking capacity 120 ka. confirming to is: 13703/iec 60269-2, suitable for 9kva transformer 415v output side hrc fuses in underslung hv power panel as per edts 355 edts, rev-1. accepted makes: siemens / wohner / italweber / ferraz / bussmann / schneider / ge / l&t only as per item no. 12,13,14 of bom in annexure-a of edts 355 edts, rev-1.
Tender For tender for supply of vehicle repair : : - tail light assy complete , complete servicing of self starter and replacement of carbon bursh set , fuse box with all fuses , door inside covers , steering wheel , gear leve boot , accelerator cable , battery cable , radiator hose pipe set , filter fuel , air filter , enfine oil as recommended by oem , drum brake pads complete , radiator fan belt , wiring harness complete , gear oil , coolent , drum brake cylinder , propeller shaft cross set of three complete , wiring and connector miscellaneous , oil and greasing , fuel tank cleaning removing all rust particles and debris , differential seaal somplete , minor denting and touching work , wheel balacing and alignment , radiator service , gear box service , engine tuning , hand brake assy , fuel tank lock , injector nozel repair , cabin roof inner lining complete , laboure charges for repair of vehicle
Tender For supply of overhauling & maintenance of cp transformer rectifier units , ac amp. meter, for detailed description refer price breakup sheet , ac volt meter, for detailed description refer price breakup sheet , dc volt meter, for detailed description refer price breakup sheet, dc amp. meter, for detailed description refer price breakup sheet, voltmeter ( psp meter ), for detailed description refer price breakup sheet, main rectifier diodes, iav 150 amp, piv - 1200 v , type- 150 lf 120 , "lightning arrestor( la) both input and output side, rms voltage rating - 500v ,rms current rating - 1.5 ka, type- lt 0.5 oe eqv", thyrister module (scrm) consisting two antiparrallel thyrister, for detailed description refer price breakup sheet, auxiliary transformer for control circuit power supply, for detailed description refer price breakup sheet, filter capacitor bank in dc output , 2500 micro farad , 150v x 6 electrolytic capacitors, relay for providing remote contacts for mcb tripped & ac supply fail faults , coil - 240 v ac coil resistance 10 k contacts 2no+2nc , 8 pin plug in type, relay for providing remote contacts for oil tank or instrument , chamber high temp. fault. coil - 240 v ac coil resistance 10 k contacts 3no+3nc , 11 pin plug in type, thermostate with adjustable temp. setting with nc contacts ( 30 to 110 setting ), indicator lamp , housed in 22.5 mm dia, 240 v, led type red colour, auto or manual mode selector rotary type, 4 pole , 2 way ,63 amps, 240 v, ac type srpm 5417b or pa 17463b, coarse manual output control switch , rotary type, 1 pole , 6 way ,63 amps, 240 v, ac type pa7163f, fine manual output control switch rotary type, 1 pole , 4 way ,63 amps, 240 v, ac type srpm 615dor pa 5163 d, coarse current limit settor switch cam type, 2 pole ,6 way ,6 amps, 240 v, type s6-61072, fine current limit settor switch, cam type, 2 pole ,6 way ,6 amps, 240 v, type s6-61072, reference electrode selector switch, cam type 2 pole ,4 way ,6 amps, 230 v, type s6-61070, local or remote control mode selector switch,toggle type 2 pole , 2 way ,6 amps, 240 v, , on or off toggle switches in various lamp and meter circuits. 1/2 pole , 2 way ,6 amps, 240 v, , current transformer for ammeter a1 ratio - 50/1, burden - 5 va ,class - 1, contactor 32 amp.bch make 3p +(1p no) with add on 240 v ac coil , breather ( 19.45 mm dia), output voltage setter potentiometer in local auto mode 2.5 k ohm 3 watt ww, output current setter potentiometer in local auto mode 1 k ohm 3 watt ww, oil temp. indicator range ( 0 to 150 o c ), 4-20ma converter module for dc output voltage signal input - 0-75v dc , output - 4 to 20 m a , max load - 600 ohm , accuracy - +-0.5 %, aux supply - 240 v, ac type-520 t, base or channel mounting type , 4-20ma converter module for dc output current signal input - 0-75a (75 mv) dc , output - 4 to 20 m a , max load - 600 ohm , accuracy - +-0.5 %, aux supply - 240 v, ac type-520 t, base or channel mounting type , "auto transformer with coarse and fine tappings for manual control dc of output, input -265 v , coarse taps- 7 nos. fine taps- 04 nos. capacity - 8000 va, insulation - class -a (oil cooled ) ", "main transformer with shield double wound primary- 240 +/- 10 %, secondary- (0-110 v), capacity - 10,000 va, insulation - class -a (oil cooled )", filter choke in dc output , 7.5 mh at 100 amp., control box for card fixing ceco-108 & ceco 105 d1 (and extra card connector having 40 slots), current or voltage control firing card control card , type- ceco- 105d1 , "remote control interface card control card ,type- ceco -108 ", "current limit setter card control card , type- ceco -35a- 2.5 v , 75a/75mv -33.33", "voltage current sensor card control card , type -ceco -19c ", pulse driver card ceco - 118 c, surge suppressor r-c network across scrs 75 ohm, for detailed description refer price breakup sheet, "fuse fail indicator module for diodes and output fuses six channel type with led indicators and 1 common no+nc contacts ,sensing