Tender For supply of spares for di water generation unit of water etching system - coarse silex , activated carbon 900 iv , 20 inch pp housing , 5 micron x 20 inch clr filter cartridge , 1 micron x 10 inch clr filter cartridge , 0 point 2 micron x 10 inch pleated cartridge , uv lamp alfa model ecs 08l , 4 mm nylon tube , 6 mm nylon tube , 8 mm pu tube , 3 by 4 inch steam solenoid valve 24v , 4 inch 4040 ro membrane to ray tm710d , 4 inch advanced end cap , 8 x 44 frp vessel , 1 by 4 inch x 4mm cdc female connectors , 1 by 4 inch x 4mm cdc male connectors , 1 by 4 inch x 4mm cdc y connectors , 1 by 4 inch x 3 by 8 cdc unf connectors , 8mm cdc tee connectors , cat ion resin for 2 bed resin , anion resin for 2 bed resin , cat ion resin for mixed bed resin , anion resin for mixed bed resin , mixed bed resin mb 108 slash mb110 , 1 inch cpvc fta , 1 inch cpvc elbow , 1 inch cpvc union , 1 inch x 3 by 4 inch cpvc reducer bush , 1 inch cpvc pipe , 3 by 4 inch cpvc fta , 3 by 4 inch cpvc elbow , 3 by 4 inch cpvc union , 3 by 4 inch x 1 by 2 inch cpvc reducer bush , 3 by 4 inch cpvc pipe , 1 by 2 inch cpvc fta , 1 by 2 inch cpvc elbow , 1 by 2 inch cpvc union , 1 by 2 inch cpvc pipe , 1 by 2 inch ss tc clamp , pneumatic rotary actuator valve , anti-scalene solution , hydrochloride acid , caustic soda , service charges , packing and transportation ,etc
Tender For corrigendum : dre224s258 service contract for steam trap system survey, continuous monitoring and rectification including supply of traps and spares in digboi refinery.
Tender For corrigendum : work of removal, supply and application of spray insulation of steam turbines and its allied system of 210 mw unit no.3, 4, 5 at gtps on as and when required basis
Tender For design,supply,fabrication,commissioning of cbc conveyor,fiber cyclone,screw feeders and sfb hopper system, modification of feeders and boiler fuel conveyor,steam lines and flow meters,etp repair works,new nut polishing drum along with supporting structure and required mechanical and electrical accessories at oil palm processing plant at apparaopet, bhadradri kothagudem dist., telangana state
Tender For corrigendum : providing of custom bid for services - drg124s270 detailed engineering consultancy for installation and commissioning of power recovery steam turbine generator system with ancillaries at cpp
Tender For erection and dismantling of sky climbers inside the boiler, water washing of water wall tubes by high pressure jet pump and carrying out d-meter survey in the areas like water circulation system and steam circulation system of stage-iv/unit-7/ dr.nttps boiler during the annual overhaul period 2025-26
Tender For t.e.no. gmscl/d-747/rc/2025-26 (on rate contract basis) - acid concentration part a, 1864000, each 1 ltr. of liquid concentrate contains:sodium chloride i.p 210.0 gm ,sodium 137.60 mmol ,calcium chloride i.p 8.0 gm, calcium 1.55 mmol , magnesium chloride i.p 2.7 gm ,magnesium 0.38 mmol ,acetic acid, glacial i.p 6.3 gm mmol, bicarbonate 32.0 ,purified water i.p qs ,chloride 106.4, acetate 3.0 dilution : 35x, haemodialysis on-off kit for dialysis procedure convenience, 789000, (1)eto/gamma/steam/inline steam/radiation(2) sterile product must pack in individual packing(3) low flux or mid flux only(4) polysulphone/polyamide blend/pmma/polyether sulphone(5) compatible with all make and model of hemodialysis machine, dialyzer (low/middle flux)- 1.0 m2 to 1.1 m2, 16000, (1)eto/gamma/steam/inline steam/radiation(2) sterile product must pack in individual packing(3) low flux or mid flux only(4) polysulphone/polyamide blend/pmma/polyether sulphone(5) compatible with all make and model of hemodialysis machine, av bloodline set post pump- hd machine (adult), 4104000, material polysulphone/ polyamide blend/ polyethersulphone/pmma (1) disposable & single use adult tubing set(2) kink resistant tubing material (3) medical grade pvc material tubing set(4) sterile, non-pyrogenic & non-toxic(5) post pump tubing set(6) tubing set contain-01 no. of transducer protector for venous line(7) to complete the circuit of haemodialysis, all necessary accessories must contain in set., arteriovenous fistula(avf) needle (16/17g), 493000, hydrogen peroxide 21 percent w/w, paracetic acid 4 percent w/w, acetic aced 10 percent w/wcolorless biodegradable liquidpackaging: virgin hdpe jerry canniister 5 litrestorage: stable at room temperature, hot disinfectant for hemodialysis(h.d.) / hemodiafiltration( hdf) machine / water treatment system, 1209000, (1)13- 13.5 cm catheter length(2) polyurethane bio-compatible material with catheter clamp and luer lock(3) radio-opaque(4) kit should contain 2 dilators: 1st dilator 10f 12-15 cm and 2nd dilator 12f 15cm as per requirement. (5) kit should contain guidewire size of 0.038 inch or 0.035 inch as per requirement.(6) surgical needled suture must be provided by bidder along with catheter kit, double lumen dialysis catheter kit 11.5-12 fr. x 15-16 cm curved/straight, 175000, (1) 9-12 cm catheter length(2) polyurethane bio-compatible material with catheter clamp and luer lock(3) radio-opaque(4) kit should contain 1 dilators: 9f 12-15 cm(5) kit should contain guidewire size of 0.025 inch (6) surgical needled suture must be provided by bidder along with catheter kit, transparent film dressing - 10cm x 12cm, 214000, non adherent sterile dressingnon-woven material, transparent 1-3 layered, acid concentration part a, 1864000, each 1 ltr. of liquid concentrate contains:sodium chloride i.p 210.0 gm ,sodium 137.60 mmol ,calcium chloride i.p 8.0 gm, calcium 1.55 mmol , magnesium chloride i.p 2.7 gm ,magnesium 0.38 mmol ,acetic acid, glacial i.p 6.3 gm mmol, bicarbonate 32.0 ,purified water i.p qs ,chloride 106.4, acetate 3.0 dilution : 35x, haemodialysis on-off kit for dialysis procedure convenience, 789000, (1)eto/gamma/steam/inline steam/radiation(2) sterile product must pack in individual packing(3) low flux or mid flux only(4) polysulphone/polyamide blend/pmma/polyether sulphone(5) compatible with all make and model of hemodialysis machine, dialyzer (low/middle flux)- 1.0 m2 to 1.1 m2, 16000, (1)eto/gamma/steam/inline steam/radiation(2) sterile product must pack in individual packing(3) low flux or mid flux only(4) polysulphone/polyamide blend/pmma/polyether sulphone(5) compatible with all make and model of hemodialysis machine, av bloodline set post pump- hd machine (adult), 4104000, material polysulphone/ polyamide blend/ polyethersulphone/pmma (1) disposable & single use adult tubing set(2) kink resistant tubing material (3) medical grade pvc material tubing set(4) sterile, non-pyrogenic & non-toxic(5) post pump
Tender For providing of custom bid for services - maintenance contract for steam and water analysis system (swas) chiller of u#1 to 6 , mtps, dvc for 01(one) year