Tender For corrigendum : providing of custom bid for services - 200154955 cfd analysis of boiler flue gas ducting in one unit of kudgi stage 01 3x8000mw, ntpc kudgi
Tender For corrigendum : tender for the supply of watertreatment chemicals - cooling water & boilerwatertreatment chemicals, corrossion inhibitor for cooling watertreatment, bio-dispersant for cooling watertreatment, mineral dispersant for cooling watertreatment, antiscalent for cooling watertreatment, antifoulant for cooling watertreatment, non oxidising biocide-1 for cooling watertreatment, non oxidising biocide-2-45% glutaraldehyde, chemical for clo2 generation, chlorine for clo2 generation, caustic soda for cooling watertreatment, anti scalant, corrossion inhibitor & sludge conditioner for boilerwatertreatment, oxygen scavenger for boilerwater treat ment, condensate line protection for boilerwatertreatment, feed water ph booster (volatile) for boilerwatertreatment, contingency chemicals for cooling watertreatment. this will not be considered for financial evaluation, hydrocarbon ingress into system, chlorination failure, ph fluctuation, lube oil/ grease ingress in to system, high iron content, high turbidity of make up water, high chloride in make up water
Tender For corrigendum : design supply testing and commissioning of 2 nos gas cum oil fired package boilers 1x6 tph and 1x8 tph along with allied civil work and dismantling of existing 2 nos of 5 tph oil fired boilers - design supply installation & commissioning of 2 nos. of gas cum oil fired package boiler capacity (1x6) tph & (1x8) tph along with allied civil works and dismantling of existing two numbers of 5tph oil fired boilers
Tender For supply of safety helmets , mask ammonia gas , gloves pu coated , cut resistant hand gloves , safety shoes , mutli gas canister or cartridge , rubber hand gloves , safety belt , boiler suit or overalls
Tender For supply of analysed oil samples and disposal record , boilerwater analysis record , calibration record, carbon analyzer , calibration record, flame aas , calibration record, analytical balance , calibration record, mass spectrometer , calibration record, weight box, e1 , calibration record, gc, mp , calibration record, ion chromatograph , calibration record, kf titrator , calibration record, ftir , calibration record, conductivity meter , cooling water analysis record, landscape , calibration record, density meter, dma 58 , density meter calibration record , dissolved oxygen record , dm plant cpp analysis record , dm plant analysis record , calibration record, flame photo meter , calibration record, h2s gas bombs, ss sample containers , lab effluents discharge , monthly report for trade effluents , na2so4, recovery analysis record , ng heavy water analysis record , non returnable material dispatch record , oxygen 18 sample analysis record , observation book for kmno4 demand , pc and al analyzed samples disposal record , calibration record, ph meter , process liquids analysis record , raw material analysis record, h2so4 , raw material analysis record, naoh , raw material analysis record, na2s and nahs , raw material analysis record, hci , raw material analysis record, alum , raw material analysis record, libr , raw watertreatment plant analysis record , rcu gas analysis record , seal and lube oils analysis record , system and purge gas analysis record , calibration record, turbidity meter , uv visible observation book , waste stripper average record , xu samples analysis record , bottom ash analysis record , boiler feed, dissolved oxygen, iron and copper record , flue gas analysis record , scc ltd. coal analysis record , spm analysis record , single ruled book
Tender For providing kitchen equipment and its accessories for two mess block of boys hostel and girls hostel in cutn thiruvarur - supplying, installation, testing, and commissioning of 85 kg/hr gas-operated steam boiler for kitchen application including all accessories etc., as required. a) gas-operated steam boiler design: cylindrical multipurpose boiler maximum steam output (@100°c): 80-90 kg/hr outlet steam condition: dry, saturated max. working pressure: 10 kg/cm² max. operating pressure: 3-4 kg/cm² safety valve set pressure: 10 kg/cm² b) mountings & fittings details main steam stop valve - 25 mm nb - 1 no. safety valve - 15 mm nb - 2 nos. shell blow down valve - 25 mm nb - 1 no. air vent valve - 15 mm nb - 1 no. isolation valve along with pressure gauge - 1 no. control bannet valve set c) t-series burner fuel: lpg type: monoblock fuel consumption: 5.8 to 6.5 kg/hr d) m.s. straight chimney, nuts & bolts, template for foundation, foundation bolts, including painted with heat resistant aluminium paint and foundation etc., as required diameter: 150 mm height: 6 m (vertical) + 1 m (horizontal connecting pipe) sheet thickness: 5 mm e) made: boiler outer shell 6 mm ss 304 grade plate (2-layers). inner shelled & kid ring is made out of 2 mm ss 304 grade stainless steel sheet & bottom 3 mm. f) type of boiler: super boiler, dimension: 35" od x 50" ht, water capacity: 750 litres