Get complete information related to latest Booster Chamber Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Booster Chamber Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Booster Chamber Tenders.
Tender For piped water supply scheme for on risk & cost piped water supply scheme for village- koti(imlidand,khaspara,korwapara) koti(panditpara) koti (daridih, pateratola, purankoti) block- wadrafnagar district – balrampur(c.g.)construction, testing and commissioning of r.c.c. elevated service reservoir of 00 kl capacities – 00 no. & staging 12 mtr& staging and steel structure 09 m height & 10 kl (5000l x 2no.)- 00 no.} pe tank & elevated service reservoirs of rcc staging and hdpe slim tank of capacity 5000 ltr of 00 no. 9 mtr staging (with switch room of size 1.8mx1.8mx3m) and 10000 ltr of 00 no. 12 mtr staging.including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber.providing, laying, jointing, interconnection, testing and commissioning of rising main upvc class 10 kg/sqcm 90 mm dia 00 m & hdpe 75mm dia 00 m & 63 mm dia 840 m., distribution upvc class 6kg/sqcm 90mm dia. 00 m., 110 mm dia. 00 m., 140 mm dia. 00 m. 160 mm dia. 00 m.& distribution hdpe class 6kg/sqcm 63 mm dia. 550 m., 75 mm dia. 1000 m.with suitable joints gi pipe, valve, specials and all fittings including all allied civil works, supplying & installation of energy taging n five star bee rating isi marked required capacity single phase / three phase, 50 hz, 220v,, deep well submersible pump stainless steel body, suitable for 4”/6” tube well with contral panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,ss/nylonwireropeandconnection cable including verification of tubewell yield& electric connection from cspdcl, construction of brick masonry switch room, construction of boundary wall around the over head tank, installation of electro chlorinator , construction of chlorinator room of providing functional household tap connection (f.h.t.c. 0 ) in individual households and government instiution etc. complete with trial run of 03 months after that o&m of 06 months under village-koti(imlidand,khaspara,korwapara)koti(panditpara) koti(daridih,pateratola,purankoti) block- wadrafnagar district – balrampur(c.g.)
Tender For piped water supply scheme for on risk & cost piped water supply scheme for village- darridih ( uraopara, purvtola ,khaspara ) block- balrampur district – balrampur(c.g.)construction, testing and commissioning of r.c.c. elevated service reservoir of 00 kl capacities – 00 no. & staging 12 mtr& staging and steel structure 09 m height & 10 kl (5000l x 2no.)- 00 no.} pe tank & elevated service reservoirs of rcc staging and hdpe slim tank of capacity 5000 ltr of 00 no. 9 mtr staging (with switch room of size 1.8mx1.8mx3m) and 10000 ltr of 00 no. 12 mtr staging.including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber.providing, laying, jointing, interconnection, testing and commissioning of rising main upvc class 10 kg/sqcm 90 mm dia 00 m & hdpe 75mm dia 00 m & 63 mm dia 00 m., distribution upvc class 6kg/sqcm 90mm dia. 00 m., 110 mm dia. 00 m., 140 mm dia. 00 m. 160 mm dia. 00 m.& distribution hdpe class 6kg/sqcm 63 mm dia. 1300 m., 75 mm dia. 127 m.with suitable joints gi pipe, valve, specials and all fittings including all allied civil works, supplying & installation of energy taging n five star bee rating isi marked required capacity single phase / three phase, 50 hz, 220v,, deep well submersible pump stainless steel body, suitable for 4”/6” tube well with contral panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,ss/nylonwireropeandconnection cable including verification of tubewell yield& electric connection from cspdcl, construction of brick masonry switch room, construction of boundary wall around the over head tank, installation of electro chlorinator , construction of chlorinator room of providing functional household tap connection (f.h.t.c. 46 ) in individual households and government instiution etc. complete with trial run of 03 months after that o&m of 06 months under village- darridih ( uraopara, purvtola ,khaspara ) block- balrampur district – balrampur(c.g.)
Tender For supply delivery and fixing of motor and accessories at ward-1 selliyampalayam oht in narasingapuram municipality - supply and delivery of kirloskar make 15hp/11kw/2900rpm three phase/415v/50hz/ac/tefc horizontal centrifugal monoblock pump impeller-mechanical seal (head-20mtr,flow rate-2154lpm) size:100x100mm (local quotation) 15hp horizontal centrifugal monoblock pump, labour charges for erection of horizontal shaft, centrifugal pumpset (coupled/monoblock) in bore well/open well including fixing of suction pipe and foot valve upto a maximum depth of 7 metres and delivery pipes to the required length with valves,pressure gauges upto the exterior wall of pump room and erection of panel board consisting of tpic switches starter, voltmeter, ammeter, capacitor single phasing preventor and laying and jointing the cables and twinearthing as per ie rules including providing bed blocks etc., complete and operating the pumps and trial run for 10 days including signing of completion of reports as required by eb authorities., three phase panel board star- delta with two level guard and auto start supply and delivery of star-delta starter confirming to is 13947, iec60947-1 and as amended thereafter with suitable kw rating for operation in ac/ three phase/50hz (+/- 5%) and 415v (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., ct operated ammeter (65 mm dia) with suppressed scale,voltmeter (65mm dia),voltmeter selector switch,miniature circuit breaker, thermal overload relay, air break contactors suitable for next standard higher kw rating, single phasing preventor, dry running preventor and on/off push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capa citor is to be taken separately). three phase panel board for 15hp, supply,delivery and fixing of the following materials are listed below etc..,as directed by the departmental ofiicers.for service4 core 16sq.mm pvc copper ug cable, for motor3 core 6sq.mm pvc insulated and sheathed flat type copper cable, 150mm di pipe, 100mm gi pipe , 100mm gi flange set, rubber sheet for flange set, ms bolt and nut20mm dia and above x 90mm to120mm length fully threaded bolts andwith nuts 2 nos. , manhole cover 60 x 60cm (heavy duty) with frame, supply, erection, testing and commissioning of cast iron body and bronze internal non-rising spindle sluice valve of sizes at required places to control the flow of water including necessary ms flange of table e , gaskets, bolts & nuts including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the departmental officers. 150mm sluice valve, 100amps 4pole mcb, 100amps porcelain fuse unit (500v), 32mm pipe
Tender For providing of repair and overhauling service - electronic weighing systems as per is 9281 (part i, part ii, part iii, part iv); defect rectification of tullu pump (capacity-01 hp) and deteriorated/damaged securing screw & hinges of engine room & asd compartment..
Tender For repair / maint of split acs 2/1.5 ton , windows acs 2 / 1.5 ton , voltage stablizers and connected items installed at command hospital (wc) and other various location in aor of age e/m ch - servicing of split type ac of capacity 2/ 1.5 tr after disconnecting all incoming and outgoing electric connection, water drain pipe line connection etc. and wash with approved chemical mixed water with the pressure pump, after servicing cleaned all the disturbed area and reassembling the water/electric connection and testing for entire satisfaction of engr-in-charge., all as per item no. 1 here-in-above but window type ac 2/1.5 tr capacity., supplying and charging of refrigerant gas r-22 only after vacuuming dehydration, leak testing of the system as per standard practice testing for proper cooling effects and satisfactory performance complete all as specified and as directed by engr-in-charge for room split/window type ac of capacity 2/1.5 tr., all as per item no: 3 above but gas r-32, all as per item no: 3 above but gas r-410a., all as per item no: 3 above but gas r-134a., taking out defective capacitor of capacity 50+6 mfd after disconnecting all incoming and outgoing electric connection including supply & fix new capacitor on same place and testing complete all as specified and as directed by engr-in-charge, all as per item no:7 here in above but of capacity 45+4 mfd ., all as per item no:7 here in above but of capacity 45 mfd ., all as per item no: 7 here in above but of capacity 6 mfd ., all as per item no: 7 here in above but of capacity 4 mfd ., supply & fixing as in replacement copper pipe 1/2" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 1/4" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 5/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 3/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply and fixing of insulation foam for copper pipe of size 1/2" after removing old one., supply and fixing of insulation foam for copper pipe of size 1/4" after removing old one., supply and fixing of insulation foam for copper pipe of size 5/8" after removing old one., supply and fixing of insulation foam for copper pipe of size 3/8" after removing old one., supply and fixing as in replacement of pvc flexible pipe 15 mm dia including any fittings as required complete inclusive of any type of leakage testing., all as per item no: 20 above but pipe of 20 mm dia., supply and fixing as in replacement of pvc water drain pipe 25 mm dia complete inclusive all fittings and any type of leakage testing., material and labour for sub main wiring with 2 x 2.5 sqmm +1 x 2.5 sqmm single core flame retardant pvc insulated unsheathed cable with stranded copper conductor drawn in and including heavy grade frlsh pvc concealed conduit isi marked with all accessories on walls and making good the disturbed surfaces including all conduits fittings, clamps guittes etc for earth dbs and boxes with proper thimbles all as directed by engr-in-charge. note :02 run of 2.5 sqmm , 01 run of 2.5 sqmm cable and 01 run of conduit shall be measured as one unit and paid accordingly., all as per item no: 23 here in above but of size 2x 4 sqmm +1x 4 sqmm., m&l cutting chases, pinning in stone concrete block or slab walls & making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring ,etc., and making good, cutting exc. 10 cm girth., supply and fix as in replacement of rigid non-metallic pvc conduit of size 20
Tender For corrigendum : construction of balancing tank, pump room, office cum storeroom, fencing, gate and other civil development works at swimming pool of rc building of nml talaipalli township
Tender For corrigendum : tender for supply of clamp meter , 5 gallon compressor oil tin , core for filter drier , filter drier core rpe48bd , relay base type rxze2m114 , relay 24v dc 4 co rxm4ab2bd , single core 40 mmsqlfh cable , ss washer 125 , screw driver set , ss 304 tubing , pilot tube fitting , filter drier replacement core , potentiometer shaft , relay , store room thermostat , piston set , valve plate set , pocket for temp switch , gasket , therm injection valve , defrost heater element tat 30 , shut off valve , shut off valve , shut off valve , temperature transmitter pt 10 , solenoid valve on oil return line , condensers of chilled water units ac , thermometer discharge line , thermometer cwinlet , flex metal hose , oil heater , therm injection valve , needle valve , gauge oil pressure , feeler pocked , stop valve , stop valve , power contactor 115 vac , air contactor , chilled water pump of air conditioning plant , fuse 500v , relay 24vdc , rc module , auto controller , antifreeze thermostat , fuse switch , fuse switch , sight glass set , current meter , pilot lamp , valve relief , metaflex coupling api 671
Tender For corrigendum : construction of pump house and control room, construction of sump well, lining of sirhind canal and neelon drain, construction of protection works at outfall of riser main, and joining of np3 700 mm dia pipe with sump well for construction of surface - construction of pump house and control room, construction of sump well, lining of sirhind canal and neelon drain, construction of protection works at outfall of riser main, and joining of np3 700 mm dia pipe with sump well for construction of surface pumps for lifting water from sirhind canal at rd 145700/r into neelon drain ( civil work )