Get complete information related to latest Booster Pump Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Booster Pump Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Booster Pump Tenders.
Tender For day to day supervision maintenance of rising main and collecting lines, periodically washing, cleaning of ohrs / cwr and upkeeping of ohrs / pump house campuses with all allied works related to water supply under arrah w/s scheme under raghunathp
Tender For barangani, khadakwasla, highway bridge, sanas shala va nanded boosterpumping yethe don varshasathi chlorine cylinder va chlorine operator purvine
Tender For repair/maint of air cooled ac plants, chiller, condenser pump, hot water boiler, ahu, water colled ac plants, motor, hwg and ahu alongwith connected items at akash complex/tech area at dappar under age(i) dappar - material and labour for servicing / cleaning of air cooled ac plants of 50 tr capacity, chiller unit, cleaning and washing of cooling coil with fins using a chemical c-shine (alkaline coil cleaner and brightener) and testing the unit (once in a three months) complete all as specified and as directed by engineer-in-charge. location :- akash air cooled ac plants(once in a three months), material and labour for descaling of complete condenser units for central/ package type ac plants of condenser unit of water cooled ac plantac plant upt to 40 tr capacities by means of adding descaling chemical solution (hcl) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and refixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc. to entire satisfaction of engineer-in-charge complete all as specified and as directed by engineer-in-charge. location :- old, 3ac igloo ac plant and new ac plant (once in a three months), material and labour for cleaning of cooling tower existing size, water basin and makeup tank with the help of chemical and nylon brush, removing and refixing of pvc finches after washing, cleaning of condenser pipe line ( inlet and outlet) including painting of out side of cooling tower with inlet and outlet pipe line with one coat synthetic enamel paint of colour approved by engineer in charge and inside painting of water tank of cooling tower using water proof black japan paint one coat including changing of unserviceable pvc guard, water distibutor, pvc pipe, and all connected minor items of up to 100 tr capacity of the ac plants at different locations complete all as specified and as directed. location :- old and new ac plant, material and labour for servicing of cooling coils and air filters of ahus intalled at air conditioning plant by removing air filters and fixing after cleaning with air blower and water and cleaning agent , cleaning of cooling coilwith wire brush and air blower and water spray pump after spraying scale gun or equivalant chemical suitable for aluminium fins and straighting the fins of cooling coil by using suitable brush for any capacity of ahu complete all as specified and as directed by engineer-in-charge. locaton :- new ac plant, old ac plant , 3 ac igloo ac and akash ac plants akash, material and labour for servicing / cleaning and testing of electrically operated pan type humidifier capacity 9 kw alongwith all necessary items fitting and all suitable / all necessary electrical wiring from electrical panle to humidifier complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in cold water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in hot water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing , cleaning , and greasing , chiller , hwg pumps , ahu and ct motors alongwith all necessary minor items/ fitting i.e bearing , star coupling , screws , nuts and bolts etc complete all as specified and as directed by engineer-in-charge. location :- new ac plant , old ac plant and air coole
Tender For corrigendum : supply of fp9750683030 boosterpump for cvp singrauli , fp9750683030 boosterpump for cvp sipat , fp9750683501 impeller with nuts and accessories , fp9750683510 impeller shaft with keys , fp9750683528 shaft sleeve , fp9750683536 wearing ring impeller , fp9750683544 wearing ring casing , fp9750683552 sleeve bearings for pump , fp9750683560 thrust bearing , fp9750683579 pump and drive motor coupling assembly , fp9750683587 pump to drive motor coupling bushes , fp9750683595 gland assembly mech seal , fp9750683609 motor for lubrication pump
Tender For supply of centrifugal pumps c c - supply of raw oil pumps , supervision of raw oil pumps , supply of heavy cycle oil circulation pumps , supervision of heavy cycle oil circulation pumps , supply of light cycle oil circulation pumps , supervision of light cycle oil circulation pumps , supply of heavy naphtha circulation pumps , supervision of heavy naphtha circulation pumps , supply of sour water pumps , supervision of sour water pumps , supply of main column reflux pumps , supervision of main column reflux pumps , supply of main column net overhead pumps , supervision of main column net overhead pumps , supply of water injection pumps , supervision of water injection pumps , supply of high pressure receiver pumps , supervision of high pressure receiver pumps , supply of primary absorber rich oil pumps , supervision of primary absorber rich oil pumps , supply of primary absorber upper intercooler pump , supervision of primary absorber upper intercooler pump , supply of primary absorber lower intercooler pumps , supervision of primary absorber lower intercooler pumps , supply of sponge absorber lean oil pumps , supervision of sponge absorber lean oil pumps , supply of lean amine boosterpumps , supervision of lean amine boosterpumps , supply of debutanizer bottoms recycle pumps , supervision of debutanizer bottoms recycle pumps , supply of debutanizer overhead pumps , supervision of debutanizer overhead pumps * /bid number : gem/2026/b/7681232 + /dated: 27-06-2026 ' ' / bid document 1 / 40
Tender For procurement of spares for boosterpump for sgtpp - procurement of procurement of spares for boosterpump for sgtpp., rotor assy. boosterpump-fa1b75 for mdbfp of 500 mw , (balanced condition), set contain one shaft, one impeller, impeller neck ring-02 nos, thrust collar, coupling key, pump drg. no- ( drg. no-hy-dg-373-139-a017 moc-shaft-bs-en-10250-4, impeller-bs-en-10213-2, impeller wear ring-bs-en-10213-2, approximate dimension- impeller od-753 mm, impeller width from neck to neck-246, impeller neck od-300 mm, neck id-265 mm, neck width-45 mm, shaft dia at impeller position-84.85 mm, no of vains-06. approximate shaft length-1725 mm, shaft run-out should be within 0.05 mm. for mdbfp , direction of rotation-anti clowise viewed from non-drive end. rotor assembly should be in balanced condition. balancing document should be submitted during delivery. all give dimensions are approximate & actual dimensions must be at per give drawing no. ), impeller for boosterpump-fa1b75, for boosterpump of 500 mw. , part no-2 , pump drg. no-hy-dg-373-139-a017, moc- bs en 10213-2 ( in balanced condition. balancing document should be submitted during delivery. moc-impeller-bs-en-10213-2, approximate dimension- impeller od-753 mm, impeller width from neck to neck-246, impeller neck od-300 mm, neck id-265 mm, neck width-45 mm, shaft dia at impeller position-84.85 mm, no of vains-06. all give dimensions are approximate & actual dimensions must be at per given drawing no. ), shaft for boosterpump-fa1b75 for boosterpump of 500 mw. , part no-5 , pump drg. no-hy-dg-373-139-a017, moc-bs en 10250-4 or equivalent ( shaft run-out should be within 0.05 mm. moc-shaft-bs-en-10250-4, approximate shaft length-1725 mm, all give dimensions are approximate & actual dimensions must be at per give drawing no. ), impeller nut, boosterpump-fa1b75 for boosterpump of 500 mw , part no-13, pump drg. no-hy-dg-373-139-a017, nut thrust collar for boosterpump-fa1b75 , pump drg. no-hy-dg-373-139-a017, casing wearing ring, f-m/cd-bp-fa1b75 for boosterpump ( moc-fv 520 b (13% cr. steel). approximate dimension od-340 mm, id-320 mm, width-45 mm, all give dimensions are approximate & actual dimensions must be at per give drawing no. ), wearing ring,impeller,fa1b75 for boosterpump fa1b75 ( moc-bs-en-10213-2, approximate dimension od-320 mm, id-300.20 mm, width-45 mm, all give dimensions are approximate & actual dimensions must be at per give drawing no. )