Tender For supply of hydraulic pusher 60ton for cbc draft gear removal arrangement, having operating pressure 250kg/sq.cm, cylinder bore dia:125mm, ram stroke: 90mm and closing height-190mm, pump 3 cc/stroke and maximum pressure 500kg/sq.cm. one set consist of 04 items-(1)hydraulic pusher cylinder 60ton- 1no./set, (2)high pressure hydraulic hand pump 01 no/set, (3)pusher assembly bracket-01no/set, (4)high pressure hydraulic hose-3mts/set, (5)one set handle extra (6)all rubber items for three phase ac loco. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of ultra-high pressure hand pumps, : portable hand pump for pinion extraction 40,000 psi (2800 bar), individual manifold release knob. fully equivalent to enarpac p-11series, model p2282, light weight and compact design, nylon reservoir and nylon encapsulated aluminum pump, non-conductive fiberglass handle, internal pressure relief valve for overload protection as per specification attached annexure-i and accessories annexure-ii attached [ warranty period: 30 months after the date of delivery ] ]
Tender For installation of electro-mechanical equipment at cps muthi for water supply to durga nagar. - h.c pumping units-2no-providing, installation, testing and commissioning of 50000 gph x 150 mtrs. head (02 no.s) horizontal centrifugal split casing pump with slow peed motor at cps muthi by way of excavation of earth work for laying of rcc foundation block. the job includes construction of foundation block for installation of 50000 gph x 150 mtrs. hend horizontal centrifugal pump set at cps muthi. by way of dismantling of old foundation blocks with the help of required tool and tackle and manual labour as per site requirement. disposing off the excavated material from the site to distance of at least 0.50 km with the help of manual labour and mechanical transport. job includes digging of pit of size 6x3.5x4and disposal of excavated material from the site of the work to the place of dumping. providing/lying of rcc foundation block of size 5x3.5x5(labove the ground level) in 1:2:3 cement concrete mix having requisite reinforcement with 12 mm dia. tor steel from center to center with proper spacing. fabrication and fitting of foundation bolts duly welded with cross members and threading at top with nut. foundation bolt shall be welded with tor steel and firmly grouted in the cement concrete mix, plastering and finishing from outside: fitting of base frame plate on the top of the block and leveling it both horizontally as well as vertically. strengthening of the base frame by providing and welding of m. s. channel cross members of required size and as per the size of frame for giving extra strength against vibration of the unit and on full load running conditions. complete job includes cost of material and labour charges for laying of the foundation block, plastering and finishing. placing horizontal centrifugal pumping unit on the base frame by using hydra crane, chain block, manual labour and other tools and tackles. leveling of the pump and motor properly on the base frame and coupling them by fitting of the m.s. coupling bolts with nuts rubber bushes and m.s. fasteners required for horizontal centrifugal pumping unit base connections with base frame job includes cost of material, carriage of machinery and allied materials to the site of work, loading/unloading and allied charges.suction line: fabrication of suction line by providing / fabrication of ms pipe of dia 150 mm. of length as per site requirement (09 mtr approx.) proper beveling of ms pipe for v-butt welding joints. the job includes providing and. fabrication of ms bends of 150 mm dia out of ms pipe 150 mm dia. providing/fabrication / fitting of ms flanges-4no wherever required and with the one flange compatible to be fitted the suction flange of both the pumps. job includes providing and fabrication of ms bends of 150 mm dia -04 no. the job also includes providing and fitting of sluice valves of 150 mm dia. (cs material)- 02no.(01 no.for each suction line of 02 pump sets) on suction lines. providing, fabrication and fitting of ms flanges at both end of sluice valve as per site requirement.delivery line: fabrication of delivery line by providing and fabrication of ms pipe 125 mm. upto manifold. proper beveling of ms pipes for v-butt welding joint. job includes fabrication/fitting of ms pipe 125 mm dia. upto manifold. job also involves making interconnection with manifold with the delivery flange of newly installed pumps. the job involves fabrication/fitting of ms bends as per site requirement no-02 out of 125 mm dia. ms pipe. fabrication of 04 no. ms flange of 125 mm dia. to match delivery flange of the pump and welding of flange with one end of the bend. makes interconnection of manifold with delivery pipe. job also includes providing/fitting of sluice valve (cs)-2no and reflux valve of 125mm-2no (cs material) on delivery side of each pumpset by the way of welding for on delivery line. all the welding work shall have to executed butt pre heated high pressure welding electrod
Tender For desilting of 600 mm id sewer line from medical mor to new bus stand kalanaur. - : desilting of sewer line/storm line with super sucker machines having high pressure jetting pump of 400 lpm and suction capacity of 4200 m3/hour. including tracing of buried manholes, taking out silt/debris and disposal of silt, installation of pumps for flow diversion, roka/plugging stand by generator for pumping, gas detector, blowers for air ventilation, provision of safety equipment, traffic control, barricading, insurance of workmen plaster of manholes, conditional assessment of sewer line with cctv pre and post desilting through cctv survey by leser profiler and submitting 3 sets of cctv in cd as per satisfaction of engineer in charge (600 mm i/d)
Tender For supply and installation of spare set of gun & hose pipe,tornado nozzle & ss lance for high pressure triplex pump system model sxw 21.35(meera pump and system) as per annexure-a or similar [ warranty period: 12 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of cell set for 3 point 5 kva gen set , battery connecting lead positive for 3 point 5 kva gen set , battery connecting lead negetive for 3 point 5 kva gen set , governer assy for 3 point 5 kva gen set , fuel pipe line for 3 point 5 kva gen set , rocker arm assy for 3 point 5 kva gen set , self starter for 3 point 5 kva gen set , high pressure pipe line for 3 point 5 kva gen set , baby filter for 3 point 5 kva gen set , clamp for 3 point 5 kva gen set , fuel pump assy for 3 point 5 kva gen set , anabond liquid gasket for 3 point 5 kva gen set
Tender For supply of multi process control trainer setup for instrumentation engineering lab under mhrd scheme - purchase of multiprocess control trainer setup for instrumentation engineering lab under mhrd scheme - multiprocess control trainer set up, multiprocess control trainer set up - specifications:- setup must contain flow, pressure, level, temperature loops also derived loops like cascade and feedforward loops. temperature loop must be independent. setups consist of a circulating closed loop water plant or circulating water system including control valve, tanks, independent pumps and necessary valves including bypass valves and rotameters. using this we can be able to do flow control loop with pid,level control loop with pid,and pressure control pid, as independent experiments.the setup must include the following:1.one linear characteristics diaphragm operated control valve with 15mm stroke 1/2-inch size, type: high-capacity globe seat leakage class (as per ansi/fci 70.2).2.measuring tank with volumetric measurement scale and 1000mm level, in of 25 ltr capacity. sump tank min of 40 ltr capacity. all tanks made of ss304, with sight glass, and finished with mat steel finish.3.2 no s smart dp transmitter for flow and level measurement with hart protocol, display and keys integrated for calibration,0-1000mmh2o measurement range,0.01% accuracy, international iso certified ce approved make,24v supply,4-20ma output, loop powered.4,1nos of magnetic flowmeter with display and keys integrated for calibration,0-2000lph measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, international iso certified ce approved make,24v supply,4-20ma output to measure flow as a independent loop.5,. smart pressure transmitter and temperature transmitters with hart protocol, display and keys integrated for calibration, pressure transmitter 0-10bar measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, temperature transmitter 0-250 rtd type international iso certified ce approved make,24v supply,4-20ma output, loop powered.6, pressure tank of 24 liters with necessary valves for pressure loop.7.1nos orifice plate (ss304) and assembly grade with flange 1/2-inch size for flow measurement.8.2 nos pumps 0.5hp, ss centrifugal pump, minimum 1-inch pipeline of ss or high-pressure withstanding plastic with plastic welding.9. rotameters 2nos 1 inch size flow: 200-2000 l/h,ss thread, clear acrylic type.10, plc control station with 4 analogue inputs and one analogue output with necessary digital inputs and outputs to operate all loops directly from panel side.plc must have ethernet connectivity with supported protocols profinet and modbus tcpip.11.required all pneumatic components to full fill the process loops such as fr,needle valves etc.12,i to p converter 4-20ma to 3-15psi with 1/4" process connection with proper copper copper tubing.13, loop including flow pid control, level pid control, pressure pid control, cascade control (level flow), ratio control (flow flow).14.all loops can be operated using a scada system and independent pushbutton control includes trend of all analogue signals and pid tuning. scada direct profinet connectivity to plc and computer with intel i5 processor, 8gb ddr3 ram,1tb sata hdd,licenced windows 11 professional.15, required a standalone software application that must be installed on pc in which it can used to control and monitor all the functions used in scada. the application must contain process parameter trend graph plot for to study about process loops.16.the whole system setup must be in ms powder coated standalone mobile table with lockable castor wheels. all the components used be industrial. copper tubing for air connection, pressure gauges 4inches 3nos, electrical wiring connection to be flexible for to connect field devices. panel with switches, indicator, test points with banana connectors as required, multistrand wire with proper insulated lugs, ferruling & neat wire dressing & clam