Web Analytics Made Easy - StatCounter

Boric Anhydride Tenders

Get complete information related to latest Boric Anhydride Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Boric Anhydride Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Boric Anhydride Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :42901834 Due date: 09 Dec, 202509 Dec, 2025 NA
Tender For purchase of equipments - purchase of equipment, 1. configuration design an 8-channel battery analyzer and its accessories 2. power 425 w3. voltage measuring range: 25 mv to 5 v, discharge minimum voltage: 0v or better, accuracy: 0.05% of fs4. current range: 0.5 ma to 6 a, accuracy: 0.05% of fs or better 5. power per channel output power: 30w, stability; +/- 0.1% of fs or better6. time rise time: 1ms (0~full range)7. frequency 10hz8. charge mode of operation: cc, cv, cccv, cp end conditions: voltage, current, relative time, capacity.9. discharge mode of operation: cc, cv, cp, cr, end conditions: voltage, current, test time, capacity, energy.10. pulse mode charge: cp mode, cc mode, discharge: cc mode, cp mode, min pulse width: 500ms, automated switch: automated switch from charge to discharge for each pulse end condition: voltage, relative time11. dcir support for the calculation of the point of the dcir12. cycle cycles: 1 65500 or better, steps: 250 or better, nested function: max three levels of loops13. protective function software, power-down data protection, user-defined safety (upper and lower) tolerance of current, voltage, and delay time14. channel features independent pairs of closed loops for the constant current source and constant-voltage source15. test reports and curves for analysis different types of curves created by software based on user definition. (voltage-time curve, current-time curve, capacity-voltage curve, loops times charge/discharge capacity curve, loops times charge/ discharge efficiency curve, etc.), data reports created by the software. comparison of the performance of the batteries tested in channels, both visually and statistically16. channels independent control17. ac input ac 220v 10% / 50hz 18. voltage and current testing sample 4 wire connecting 19. noise 85db20. data management mysql database21. communication means tcp/ip protocol22. data output excel, txt23. communication interface ethernet port24. number of channels per cabinet 825. accessories: 1. bi-potentiostat: electrochemical workstation or moduletechniques the system should be capable of running the rde / rrde technique simultaneously cyclic voltammetry (cv) with simulation/fitting programs linear sweep voltammetry (lsv) with stripping bulk electrolysis with coulometry (be) differential pulse voltammetry (dpv) with stripping normal pulse voltammetry (npv) with stripping tafel plot (tafel), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear polarization, corrosion current, etc. multi-current steps (istep) amperometric i-t curve (i-t) lifetime testing open circuit potential time (ocpt) chrono amperometry (ca) chrono coulometry (cc) chronopotentiometry with current ramp (cpcr) potentiometric stripping analysis (psa) auxiliary signal measurement channel ir compensation external potential input galvanostatic charge discharge single/multiple cycle -chrono potentiometry (cp) with potential limits, polarity by potential or time, no. of cycles etc. voltage vs current density curves single or multiple potential steps with charge limits, single or multiple current steps, mixed voltage/current control using macro. i-v measurements, i max, pmax, fill factor, etc.impedance ac impedance (imp) 10 hz to 3mhz impedance time (impt) (mott-schottky) impedance potential (impe) impedance simulator with fitting open circuit potential time (ocpt)hardware specification of bi-potentiostat workstation/ module: potentiostat / galvanostat module, 2- or 3- or 4-electrode configuration maximum potential: 10v, maximum current: 250 ma peak or better and 2 amps with +/-25 volts for higher current measurement. compliance voltage: > 13v or better, potentiostat rise time: 300 ns or better galvanostat applied current range: 3na to +/- 100ma or better and upto 2 amps applied current accuracy: 20 pa or better input bias current: 1 pa or better cv and lsv scan rate: 0.000001 to 10,000 v/s. ca and cc pulse width: 0.0001 to 1000 sec imp frequency: 0.00001 t

State Government

CTN :42756396 Due date: 05 Dec, 202505 Dec, 2025 NA
Tender For purchase of recovery and rejuvenation lab equipments - percussion massager (gun massager), key features- percussive action: a percussive action that provides rapid and repetitive strokes to muscles and tissues- adjustable speed: adjustable speed settings to customize the massage experience- multiple attachment heads: multiple attachment heads for targeting different muscle groups and areas of tension- ergonomic design: ergonomic design for comfortable grip and reduced fatigue- blue tooth integration- powerful motor with 37 pounds of stall forceperformance specifications- speed range: with at-least 3 speed variation with lcd screen display- build in led light therapy- built in biometric sensor- guided breath workbattery life usb - c chargingattachments- standard ball- dampener- thumb- micro point- wedge-to emit heat- for cold treatmentsafety features- overheat protection: overheat protection to prevent damage to the motor and ensure safe use- automatic shut-off: automatic shut-off feature to prevent prolonged use and reduce risk of injury- soft start: soft start features to prevent sudden jolts or shocksadditional features- portability: compact and lightweight design for easy transport and storage- quiet operation: quiet operation for discreet use in various settings- customizable settings: customizable settings for personalized massage experiencecertifications: ce , fda clearance, vibration platform, adjustable frequency- 15hzs to 40 hzamplitude setting- 80 watt, pmdc motor supports upto 150kgremote control operatedatleast 3 preprogrammed modes non slip platform, steam room, steam generator- power output: generator should match a steam room of appox. 50 to 200 cubic footage (6-7.5 kw)- installation location: should be installed upto 60feet away from the steam room, ideally in a closet or heated attic/basement- features: automatic flushing, aromatherapy, and energy efficiencyroom design and materials- waterproofing: apply a waterproof membrane to walls, floor, and ceiling to prevent moisture damage- tiling: use non-porous tiles like porcelain or glass, and ensure a slight slope for water drainage- flooring: choose textured or anti-skid tiles to prevent slipping- insulation: insulate walls and ceiling to preserve heat and increase energy efficiencyventilation and safety- ventilation system: install an exhaust fan, sloped ceiling, and floor drain to remove excess water and maintain air quality- door and seals: ensure a properly sealed door with tempered glass, tight seals, and corrosion-resistant materials- lighting: use waterproof, sealed light fixtures like harvia fiber optic lightscontrol panel and accessories- control panel: install a touchscreen panel to control temperature, lighting, music, and aromatherapy- seating: choose water-resistant materials for benches, and consider fold-down seats or heated seats for luxury- aromatherapy: use essential oils to enhance thesteam room experience., sauna room, sauna heater with thermostat- type: electric, wood-burning, or infrared heater.power output: heater should match sauna room with 50-200 cubic footage (5-8 kw)room design and materials- insulation: high-quality insulation materials like mineral wool or fiberglass to maintain heat and energy efficiency- wood: durable, heat-resistant woods like cedar, aspen, or hemlock for interior lining- flooring: non-slip flooring materials like ceramic tiles or wood with a textured finish- ventilation: proper ventilation with adjustable vents to control airflow and humiditysafety features- temperature limiter: install a temperature limiter to prevent overheating and ensure safety- guardrail: install a guardrail around the heater to prevent accidental contactlighting: use heat-resistant lighting fixtures and ensure proper wiring and electrical safety control unit to regulate heat, foam rollers, material and density- eva (ethylene-vinyl acetate) foam: a popular choice for foam rollers due to its durability and comfort.- high-density foam: provide
 Loading, Please wait...

Connect us via What's Up