Web Analytics Made Easy - StatCounter

Bracket Insulator Tenders

Get complete information related to latest Bracket Insulator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bracket Insulator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bracket Insulator Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40780456 Due date: 17 Jul, 202517 Jul, 2025 6.78 Lacs
Tender For work of removal and application of thermal insulation on as and when required basis for boiler unit no 7, wtps

State Government

CTN :40752680 Due date: 01 Jul, 202501 Jul, 2025 NA
Tender For work of removal, providing and application of thermal insulation with gi & ribbed sheet cladding at boiler casing, penthouse headers, main steam, hrh and crh lines of nashik tps 210 mw unit-3 boiler during overhaul

State Government

CTN :40752688 Due date: 01 Jul, 202501 Jul, 2025 NA
Tender For work of removal, providing andapplication of thermal insulation mattresses to ,steam/feed/atomizing/oillines/prds/ drum down comer lines/pww headers and other lines of unit- 3 boiler at ntps

CTN :40534248 Due date: 23 Jun, 202523 Jun, 2025 3.97 Crore
Tender For corrigendum : supply and application of insulation materials on pipe, equipment for part a and part b as per standard specification by providing all required materials in connection with the composite work for setting upof hpg-2, butene-1 and psa units atlepetkata - legends / notes for insulation workstypes of insulation : ih = insulation for heat conservation it = insulation for steam traced lines is = insulation for personal safety ic = cold insulation for anti-condensation ie = insulation for electrically traced lines ij = insulation for jacketed lines ik = insulation for dual insulated lines basic line surface materials : cs = carbon steel (including lt carbon steel), as = alloy steel, ss = stainless steelnotes :1. for insulation type it,tracer size and tracer numbers shall be as per specification.2. insulation thickness for ic where insulation material is poly urethane foam (puf) / poly isocyanurate (pic) + cellular glass includes outer layer of 50mm of cellular glass and inner layer of balance thickness of puf/pic.3. insulation for ie consists of inner layer of rockwool and outer layer of puf / pic. the thicknesses have been specified as thk(i) and thk(o) for inner and outer layers respectively., part a, hot insulation (units)providing thermal insulation including supply of all insulating and ancillary materials, vapour barrier, weather protective coverings, consumables and other necessary materials , testing of materials as required, including transportation of materials to work site, duly inspected by 3rd party inspector(llyods/bv/dnv or any other client approved party) at manufacturers shop & sample check/inspection at site by eil construction inspector, applying insulation on surfaces as specified including all preparatory work there on, binding, tying, lacing, stitching and/or otherwise securing , finishing with sheet cladding as per spec. , providing bolts, rivets, and self tapping screws wherever specified , providing inspection windows, end seals for flanges etc., colour coding and identification. providing steel scaffolding, all tools , tackles , equipments etc. , labour, supervision and completing the work in all respect, at all heights as per drawings , specifications and instructions of engineer-in-charge. (refer legend for applicable eil specification), insulation type : ih ; surface material : cs & as ; operating temp. range : upto 125 (deg c) ; insulation material : rockwool, pipes, nb 00.75 inches; thickness 25 mm, nb 01.00 inches; thickness 25 mm, nb 01.50 inches; thickness 25 mm, nb 02.00 inches; thickness 25 mm, nb 03.00 inches; thickness 25 mm, nb 04.00 inches; thickness 25 mm, nb 06.00 inches; thickness 25 mm, blind flange assemblies, nb 00.75 inches; thickness 25 mm, nb 02.00 inches; thickness 25 mm, valve assemblies, nb 00.75 inches; thickness 25 mm, insulation type : ih ; surface material : cs & as ; operating temp. range : 126 (deg c) to 350 (deg c) ; insulation material : rockwool, pipes, nb 00.50 inches; thickness 25 mm, nb 00.50 inches; thickness 40 mm, nb 00.75 inches; thickness 25 mm, nb 00.75 inches; thickness 40 mm, nb 00.75 inches; thickness 50 mm, nb 01.00 inches; thickness 25 mm, nb 01.00 inches; thickness 40 mm, nb 01.00 inches; thickness 50 mm, nb 01.50 inches; thickness 25 mm, nb 01.50 inches; thickness 40 mm, nb 01.50 inches; thickness 50 mm, nb 02.00 inches; thickness 25 mm, nb 02.00 inches; thickness 40 mm, nb 02.00 inches; thickness 50 mm, nb 02.00 inches; thickness 65 mm, nb 03.00 inches; thickness 25 mm, nb 03.00 inches; thickness 40 mm, nb 03.00 inches; thickness 50 mm, nb 03.00 inches; thickness 65 mm, nb 04.00 inches; thickness 25 mm, nb 04.00 inches; thickness 40 mm, nb 04.00 inches; thickness 65 mm, nb 06.00 inches; thickness 40 mm, nb 06.00 inches; thickness 65 mm, flange assemblies, nb 01.50 inches; thickness 25 mm, nb 01.50 inches; thickness 50 mm, nb 02.00 inches; thickness 25 mm, nb 02.00 inches; thickness 40 mm, nb 02.00 inches; thickness 50 mm, nb 03.00

Central Government/Public Sector

CTN :40701230 Due date: 03 Jul, 202503 Jul, 2025 NA
Tender For supply of porcelain bracket insulator (minimum c.d. 1050 mm.) (r.i. 6030-1) (minimum c.d.1050 mm), as per rdso specification no. ti/spc/ohe/ins/0071 or latest (as on date of opening of tender) [ warranty period: 30 months after the date of delivery ]

State Government

CTN :39883053 Due date: 23 Jun, 202523 Jun, 2025 10.26 Lacs
Tender For corrigendum : work of supply and application of spray thermal insulation for turbines & turbine related various piping and valves of 250 mw units 3&4 of stps on as & when required basis.

Central Government / Public Sector

CTN :40503448 Due date: 30 Jun, 202530 Jun, 2025 NA
Tender For supply of porcelain bracket insulator (ri 6030-1) (1050mm cd) for 25kv, ac, 50 hz, single phase over head traction lines as per rdso spec no.ti/spc/ohe/ins/0071, str: ti/str/010 rev-01 [ warranty period: 30 months after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up