Web Analytics Made Easy - StatCounter

Brain Imaging System Tenders

Get complete information related to latest Brain Imaging System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Brain Imaging System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Brain Imaging System Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :42079041 Due date: 08 Dec, 202508 Dec, 2025 NA
Tender For corrigendum : procurement and supply of magnetic resonance imaging system (mri) 1.5 telsa with 60 cm bore to government hospitals / institutions in telangana state under rate contract for a period of one year (3rd call)

CTN :42079047 Due date: 08 Dec, 202508 Dec, 2025 NA
Tender For corrigendum : procurement and supply of magnetic resonance imaging system (mri) 1.5 tesla with 70 cm bore to government hospitals / institutions in telangana state under rate contract for a period of one year (3rd call)

CTN :42079054 Due date: 08 Dec, 202508 Dec, 2025 NA
Tender For corrigendum : procurement and supply of magnetic resonance imaging system (mri) 3 tesla to government hospitals / institutions in telangana state under rate contract for a period of one year (2nd call)

CTN :42579205 Due date: 12 Dec, 202512 Dec, 2025 NA
Tender For corrigendum : supply of schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.) - schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.), polyster base round corner x-ray films (8" x 10") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (10" x 12") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (12" x 15") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, dental x-ray films intraoral periapcal the density values should blue base with base fog less than or equal to 0.20 & dmax not less than 3.10 the density values should be met at developer temperature 32 c to 35 c, liquid developer replenisher for automatic processor (starter solution, if recommended by the manufacturer, should also be supplied), ( price of item no. 5 and item no. 6 will be considered as a unit), liquid fixer hardner for automatic processor ( price of item no. 5 and item no. 6 will be considered as a unit), inj. meglumine diatrizoate sodium diatrizoate iodine content 365-375 mg/ml in 20 ml. ampoule/vial, pigtail angiography catheter with multiple side holes length 65 to 75 cm 5f, inj. gadolinium based contrast for mri for liver/liver specific (should provide details of compound being hepatobiliary specific), inj. gadolinium based contrast for mri for general use, inj. gadolinium based contrast for mri for angiography, disp lure lock syringes 3 ml. for glue injection, disp lure lock syringes 1 ml. for glue injection, x-ray folders laminated 250 gsm 14 1/2" x 17 ", dual pack 200 ml syringe with aspirator, "y" shaped coiled tube y-tube sterile, non-pyrogenic (minimum 300 psi & above) compatible with dual head pressure injector ( lf/medrad/ sea crown / spectra / apollo), extension "y" shaped coiled tubing for injector 150 cms. (-5 or +15cm) low pressure (minimum 300 psi & above), dual disposable syringes (60 to 65 ml each) with "y" or "t"shaped coiled tube connecting tubes small spike for contrast and large spike for saline compatible with mri injector (lf or medrad)., one way stopcock (high pressure), low pressure extension "y" or "t" shaped coiled tubing min. 150cms (-5 or +15 cms) with coiled connecting tubes & small spike for contrast & large spike for saline for medical mri injector., flavoured, ionic, water soluble, oral contrast iodine content 240-250 mg/ ml. in 30 ml, bernstein catheter 4 f 100 cm, bernstein catheter 5 f 100 cm, chiba needle 21 g 15 cms length, chiba needle 22 g 15 cms length, disposable c t scan pressure injector syringes (190 ml syringe + quick fill tube) for bayer medrad salient injector (toshiba / canon), extension "y" shaped coild tube adapter dual check valves (minimum psi 300 & above), nonionic iodixanol isoosmolar, 320 mg 50 ml, disposable mri syringes kit for 65/115 mr injector system 65 ml contrast syringes and 115 ml ns syringes with connecting tubing combo pack for spectris solaris medrad pressure injector, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 14 g & 10 cm in length, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 16 g & 10 cm in length, coil shape breast tissue marker with both front trigger & an alternate rear trigger, should be visible in ultrasound, mammography and mri, extension coiled tube with integr

CTN :42901821 Due date: 18 Dec, 202518 Dec, 2025 1.00 Crore
Tender For supply of implants /pacemaker /accessories, on rate contract basis - single chamber, ssi, ssir, ssir (paediatrics), ssi mri compatible, ssir mri compatible, vdd/vddr, dual chamber, ddd, dddr, ddd (mri compatible), dddr (mri compatible), dddr ( with at/af management), biventricular pacemakers(crt devices)-crt-p/crt-d, crt-p, crt-p advanced, crt-d, crt-d advanced, crt-d (mri conditional), crt-d (with only lv pacing option), crt-d (with only lv pacing option; mri conditional), "biventricular pacemaker with atrial , rv, quadripolar lv leads and all accessories (mri compatible)", "biventricular pacemaker with atrial , rv, quadripolar lv leads and all accessories(mri compatible)-advanced", icd , single chamber (icds), single chamber (icds)-advanced, single chamber (mri icds), dual chamber (icdd), dual chamber (mri icdd), icd ( with at/af diagnosis), biventricular pacemaker + icd (combo device), biventricular pacemaker + icd (combo device) with atrial , rv, bipolar lv leads, biventricular pacemaker + icd (combo device) with atrial, rv, quadripolar lv leads (mri compatible ), advanced biventricular pacemaker + icd (combo device) with atrial, rv, quadripolar lv leads (mri compatible), leadless pacemaker, implantable loop recorder, implantable loop recorder <1.5cc, ssir mri compatible advanced, dddr mri compatible - advanced, single chamber (mri icds) with bluetooth feature, single chamber (mri icds) with bluetooth and advanced features, dual chamber (mri icds) with bluetooth feature, dual chamber (mri icds) with bluetooth and advanced features, advanced biventricular pacemaker + icd (combo device) with atrial, rv, quadripolar lv leads (mri compatible) with bluetooth connectivity, advanced biventricular pacemaker + icd (combo device) with atrial, rv, quadripolar lv leads (mri compatible) with bluetooth connectivity and multipoint pacing, single chamber rate responsive pacemaker -1, single chamber rate responsive pacemaker -2, double chamber rate responsive pacemaker - 3, double chamber rate responsive pacemaker - 4, dx icd , sicd - lead less single chamber icd. it is a propritory product for boston scientific with 8 years longevity and 81 jule deliverable energy specially indicated for patients who are diabetic, more prone for infection, young patients etc., " conduction system pacing - pre-shaped catheter for conduction system pacing compatible with routine active fixation pacing lead.• catheter should be able to deliver all active pacing fixation, stylet driven extendable helix leads with diameter of 6fr or below.• multiple options of shape availability for various anatomies.• catheter should have integrated hemostasis valve along with facility of contrast injection port.• atraumatic radiopaque tip to facilitate imaging under fluoroscopy.• catheter should have outer diameter of 9fr or less.• should be supplied with compatible 0 .035” guidewire and slitter.• helix locking tool (hlt) along with the catheter provides alternative to the clip – on tool used for retracting /extending of helix."

State Government

CTN :42696204 Due date: 26 Dec, 202526 Dec, 2025 4.03 Crore
Tender For corrigendum : supply of intraventional radiology and radiology& ct/mri to kmio - semiautomatic biopsy gun 18g - 15cm(co-axial system) kmio, pigtail catheter 12fr kmio, pigtail catheter 10fr kmio, percutaneous transhepatic biliary drainage catheter 12f kmio, percutaneous transhepatic biliary drainage catheter 10f kmio, malecot catheter 20f kmio, malecot catheter 18f kmio, malecot catheter 16f kmio, malecot catheter 14f kmio, malecot catheter 12f kmio, chiba needles 15cms-21g kmio, chiba needles 15cms-18g kmio, chemo port 9.6 fr kmio, chemo port 6.6 fr kmio, chemo port 4.4 fr, bone marrow biopsy gun 15cm 11g kmio, bone marrow biopsy gun 10cm 13g kmio, biliary manipulation catheter 6f kmio, automatic biopsy gun 25cm 18g kmio, automatic biopsy gun 15cm 18g kmio, automatic biopsy gun 10cm 16g kmio, ultrasound gel 5kg kmio, ultrasound gel 250 ml kmio, non ionic low osmolar contrast media iohexol/iopromide or iopamidol or equivalent concentration 300mg/dl 100ml, non ionic low osmolar contrast media iohexol/iopromide or iopamidol or equivalent concentration 340mg/dl 100ml, non ionic iso osmolar contrast media iodixanol concentration 270mg/dl 100ml kmio, macrocyclic mr equivalent gadotecic acid/gadobutrol/gadoterate or gadoteric acid or equivalunt molecule 10ml, 0.5mmol / 1 mmol , ionic contrast media for non vascular purpose gastrograffin/urograffin concentration 350mg/dl 100ml kmio, electrode gel 250ml(for ecg) kmio, ecf and gadedeamide or gadobenate or equivalent hepato specific contrast 10ml

CTN :42866948 Due date: 08 Dec, 202508 Dec, 2025 NA
Tender For supply of 3 tesla mri conditional combo-device crt-d (df-4) with quadripolar lv lead & accessories: 1. pacing mode - dddr, ddd, ddir, ddi, ddt, door, vdd, vvir, vvi, vvt, voo, ovo, voor, aai, aair, aat, aoo, oao, aoor. 2. should be capable to have anti trachycardia pacing (atp). 3. should deliver shock with 35 joules. 4. endocardial electrodes; a) right ventricular with shock coils. (i) steroid eluting or coated electrode.(ii) polyurethane & (iii) must be negotiated with 7f or less pli in size. b) atrial: (i) steroid eluting or coated electrode. (ii) screw in. & (iii) thin enough to negotiate with 9f pli or less ion size. c) left ventricular electrode with delivery system: (i) over the wire with both stylet and guide wire deliver and (ii) very thin around 4f in size to be lodged in post-lateral vein in coronary sinus. 5. epicardial electrode: to be given if endocardial lv is not possible. 6. delivery system should include a hemostatis valve b. peel away guiding catheter and wire with an option to choose from different curves caths and venogram apparatus. 7. must be supplied with all necessary compatible plis along with fluoroscopy tube covers. 8. must have at least 6 yrs. of full warranty on ipg provided by the parent company. 9. the oem must have registered office with service personnel available round clock.

State Government

CTN :41524390 Due date: 17 Dec, 202517 Dec, 2025 3.70 Crore
Tender For corrigendum : technical specification point wise dbs implant & accessories - dbs rechargeable with directional lead with25yr battery life & image guided programming integrated inside clinician programmer with micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers, usfda & ce approved kit contents: rechargeable pulse generator-1 , directional lead kit -2 , extension kit -2 , burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1, patient charging kit -1 , dbs rechargeable with non directional lead with 25yr battery life & image guided programming integrated inside clinician programmer micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers. have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage, usfda & ce approved kit contents:rechargeable pulse generator -1, non-directional lead kit -2, extension kit -2, burr hole locking kit -2, tunneling tool -1, patient remote control kit -1, patient charging kit -1, dbs non rechargeable with directional lead with image guided programming integrated inside clinician programmer micc multiple independent current control technology &bluetooth connectivity with clinician and patient programmers,usfda & ce approved kit contents: non-rechargeable pulse generator -1 , directional lead kit -2 , extension kit -2, burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1,), dbs non rechargeable with non-directional lead with image guided programming integrated inside clinician programmermicc multiple independent current control technology withbluetooth connectivity with clinician and patient programmers. should have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage,usfda & ce approved kit contents: non-rechargeable pulse generator -1, non-directional lead 1), dbs implant kit with non-rechargeable, 3t mri compatible and sensing enabled ipg and directional leads.the implanted pulse generator (dbs neurostimulator- ipg) should have a minimum service life of 5-7 years and there should not be a need to recharge it periodically.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the leads should be able to stimulate in specific directions, in addition to the ability to stimulate circumferentially. markers on leads should facilitate directional programming even if lead rotates. the leads should also be able to sense lfps.burrhole kit should be there for securing lead in place. microelectrodes for intra op stimulation and recording should be there.the extension connecting the lead and ipg should be flexiblethere should be a tunneller to place the extension wire and the tunneller should be metallic and firm to enable smooth tunnelling.the system should have approval for conditional full-body 1.5t & 3t mri compatibility.patient programmer, enabling the patient to see and if needed, modify the stimulation under guidance, should be available. patients should be able to mark dyskinesia, tremor etc. using the programmer., dbs implant kit with rechargeable, 1.5t & 3t mri compatible and sensing enabled ipg and directional leads.the implantable pulse generator (dbs neurostimulator- ipg) should have a service life of 15+ years if regularly recharged by the patient at specified intervals.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the system shou

CTN :41826591 Due date: 08 Dec, 202508 Dec, 2025 25.00 Crore
Tender For corrigendum : project for supply, installation, operation and maintenance of 01 no. 3.0 tesla mri machine system along with providing investigation related services on revenue sharing basis on ppp mode for member secretary, rmrs, pbm, bikaner

CTN :42702409 Due date: 02 Dec, 202502 Dec, 2025 NA
Tender For rate contract for supply of diagnostic accessories and consumable item at agmc and gbp hospital - rate contract for supply of diagonestic accessories and consumable items at agmc & gbph, agartala., ecg jelly, as per dnit, ecg chest electrode (disposable), as per dnit, clip arm electrode for ecg, as per dnit, patient cable of bpl 6108, as per dnit, ecg rubber bulb, as per dnit, ecg clip, as per dnit, ecg 3 pin cgarger cable, as per dnit, ecg cable 3 channel, as per dnit, ecg cable 12 channel, as per dnit, usg thermal paper, high glossy, 110 mm x 18 mm upp-110 hg, as per dnit, usg jelly, size- 250 ml per unit, as per dnit, x-ray lead number (r-l), as per dnit, chest electrode, as per dnit, x-ray view box (three in one, led x-ray viewer box with adjustable illumination system, as per dnit, mri film envelope with print, size 15 x 19 pp bgs- 120 microns multicolour printing 14.55 x 17.5 (plus handle) pasted with pur glue, as per dnit, x-ray film envelope with print, size- 10.7 x 12.7 inches, 12 gsm sunshine multicolour printing, as per dnit, usg film envelope with print, size- 10.7 x 12.7 inches, 120 gsm sunshine, as per dnit, ct scan film envelope with print, size- 15 x 9 pp bgs- 12 microns multicolour printing 14.5 x 17.5 (plus handle) pasted with pur glue, as per dnit, ecg paper, size- 210 mm x 20 mtrs, as per dnit, ecg paper of bpl 6108t, size- 50 mm x 20 mm, as per dnit, ecg paper eden se- 1201, (210mm x 140 mm), as per dnit, ecg paper, size- 80 mm x 20 mm, as per dnit
 Loading, Please wait...

Connect us via What's Up