Get complete information related to latest Brass Socket Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Brass Socket Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Brass Socket Tenders.
Tender For material supply-- pvc pipe 1/2 inch (plasto) 10 feet, pvc pipe 3/4 inch (plasto) 10 feet, pvc pipe 1 inch (plasto) 10 feet, pvc elbow 1/2 inch, pvc elbow 3/4 inch, pvc elbow 1 inch, pvc socket 1/2 inch, pvc socket 3/4 inch, pvc socket 1 inch, pvc tee 1/2 inch, pvc tee 3/4 inch, pvc tee 1 inch, pvc mta (female) 1/2 inch, pvc mta (female) 3/4 inch, pvc mta (female) 1 inch, pvc fta 3/4 inch, pvc fta 1/2 inch, pvc fta 1 inch, brass elbow 1/2 inch, brass elbow 3/4 inch, brass elbow 1 inch, brasssocket 1/2 inch, brasssocket 3/4 inch, brasssocket 1 inch, pvc solution 50 ml, pvc solution 100 ml, pvc solution 200 ml, pvc tap 1/2 inch, pvc pipe 75 mm, pvc pipe 90 mm, pvc pipe 110 mm, pvc saddle - 64 * 1/2, pvc elbow 75 mm, pvc elbow 90 mm, pvc elbow 110 mm, pvc socket 75 mm, pvc socket 90 mm, pvc socket 110 mm, pvc solvent, ferrule, end cap 1/2 inch, end cap 3/4 inch, end cap 1 inch, end cap 75 mm, end cap 90 mm, end cap 110 mm, water tank 500 liters, water tank 1000 liters, pvc tee 75 mm, pvc tee 90 mm, pvc tee 110 mm, modi pipe 1/2 inch, modi pipe 3/4 inch, modi pipe 1 inch, gi valve, ball valve
Tender For supply of set of main assembly, pneumatic, electrical and electronics components (as per annexure) for computerized controlled brake (ccb) system (version 2.0) for hhp locomotives. [ warranty period: 30months after the date of delivery ] ]
Tender For corrigendum : comprehensive repair of electrical control panels and replacement/servicing of starter components across various rural water supply schemes in the suratgarh sub-division under division suratgargh
Tender For corrigendum : comprehensive repair of electrical control panels and replacement/servicing of starter components across various urban water supply schemes in the suratgarh sub-division under division suratgargh
Tender For corrigendum : comprehensive repair of electrical control panels and replacement/servicing of starter components across various rural water supply schemes in the suratgarh sub-division under division suratgargh
Tender For corrigendum : comprehensive repair of electrical control panels and replacement/servicing of starter components across various urban water supply schemes in the suratgarh sub-division under division suratgargh
Tender For technical upgradation of duo 8052,8059,8074,8078,8089 &3321 - dismantling, inspect, repair, recondition and fixing of electrical components & external rewiring for duomatic machines., dismantling, inspect, repair, recondition and fixing of pneumatic components for duomatic machines, dismantling, inspect, repair, recondition and fixing of hydraulic components for duomatic machines, dismantling, inspect, repair & recondition wherever required and fixing & assembling mechanical & transmission & under carriage components for duomatic machines., dismantling, inspect, repair & recondition and fixing of cabin components for duomatic machines., installation of split ac (220v/1 kw (qty-01)) with 5kva dg set (qty-01) in cabin., supply & installation of hydraulic filtration unit., supply & fixing of twin beam head lights, taillights, flasher lights, - dismantling, inspect, repair, recondition and fixing of electrical components & external rewiring for duomatic-3321 machine, - dismantling, inspect, repair, recondition and fixing of pneumatic components for duomatic 3321 machine, dismantling, inspect, repair, recondition and fixing of hydraulic components for duomatic 3321 machine., dismantling, inspect, repair & recondition wherever required and fixing & assembling mechanical & transmission & under carriage components for duomatic 3321 machine., - dismantling, inspect, repair & recondition and fixing of cabin components for duomatic 3321 machine., - checking, testing, calibration and commissioning of complete machine at site for duomatic 3321 machine., installation of split ac (220v/1 kw (qty-01)) with 5kva dg set (qty-01) in cabin of duomatic 3321 machine, supply & installation of hydraulic filtration unit for duomatic 3321 machine., installation & implementation of electrically operated emergency backup system for duomatic 3321 machine., - supply & fixing of twin beam head lights, taillights, flasher lights for duomatic 3321 machine..
Tender For corrigendum : providing and fitting of pumping unit of 02 cusec capacity and other electro mechanical components of lis dangiwacha (4702) irrss2021100087--_various mechanical and electrical work to be carried out at lift irrigation scheme dangiwacha revised.
Tender For supply of multi process control trainer setup for instrumentation engineering lab under mhrd scheme - purchase of multiprocess control trainer setup for instrumentation engineering lab under mhrd scheme - multiprocess control trainer set up, multiprocess control trainer set up - specifications:- setup must contain flow, pressure, level, temperature loops also derived loops like cascade and feedforward loops. temperature loop must be independent. setups consist of a circulating closed loop water plant or circulating water system including control valve, tanks, independent pumps and necessary valves including bypass valves and rotameters. using this we can be able to do flow control loop with pid,level control loop with pid,and pressure control pid, as independent experiments.the setup must include the following:1.one linear characteristics diaphragm operated control valve with 15mm stroke 1/2-inch size, type: high-capacity globe seat leakage class (as per ansi/fci 70.2).2.measuring tank with volumetric measurement scale and 1000mm level, in of 25 ltr capacity. sump tank min of 40 ltr capacity. all tanks made of ss304, with sight glass, and finished with mat steel finish.3.2 no s smart dp transmitter for flow and level measurement with hart protocol, display and keys integrated for calibration,0-1000mmh2o measurement range,0.01% accuracy, international iso certified ce approved make,24v supply,4-20ma output, loop powered.4,1nos of magnetic flowmeter with display and keys integrated for calibration,0-2000lph measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, international iso certified ce approved make,24v supply,4-20ma output to measure flow as a independent loop.5,. smart pressure transmitter and temperature transmitters with hart protocol, display and keys integrated for calibration, pressure transmitter 0-10bar measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, temperature transmitter 0-250 rtd type international iso certified ce approved make,24v supply,4-20ma output, loop powered.6, pressure tank of 24 liters with necessary valves for pressure loop.7.1nos orifice plate (ss304) and assembly grade with flange 1/2-inch size for flow measurement.8.2 nos pumps 0.5hp, ss centrifugal pump, minimum 1-inch pipeline of ss or high-pressure withstanding plastic with plastic welding.9. rotameters 2nos 1 inch size flow: 200-2000 l/h,ss thread, clear acrylic type.10, plc control station with 4 analogue inputs and one analogue output with necessary digital inputs and outputs to operate all loops directly from panel side.plc must have ethernet connectivity with supported protocols profinet and modbus tcpip.11.required all pneumatic components to full fill the process loops such as fr,needle valves etc.12,i to p converter 4-20ma to 3-15psi with 1/4" process connection with proper copper copper tubing.13, loop including flow pid control, level pid control, pressure pid control, cascade control (level flow), ratio control (flow flow).14.all loops can be operated using a scada system and independent pushbutton control includes trend of all analogue signals and pid tuning. scada direct profinet connectivity to plc and computer with intel i5 processor, 8gb ddr3 ram,1tb sata hdd,licenced windows 11 professional.15, required a standalone software application that must be installed on pc in which it can used to control and monitor all the functions used in scada. the application must contain process parameter trend graph plot for to study about process loops.16.the whole system setup must be in ms powder coated standalone mobile table with lockable castor wheels. all the components used be industrial. copper tubing for air connection, pressure gauges 4inches 3nos, electrical wiring connection to be flexible for to connect field devices. panel with switches, indicator, test points with banana connectors as required, multistrand wire with proper insulated lugs, ferruling & neat wire dressing & clam
Tender For repairing, servicing, testing, commissioning and overhauling of iron removal plant and water softening plant, including replacement of defective mechanical, electrical and filtration components at the north side of ic block near type-iii block, gpra, salt lake, kolkata to restore and make the plants operational, complete as per direction of the engineer-in-charge.