Web Analytics Made Easy - StatCounter

Brass Valve Tenders

Get complete information related to latest Brass Valve Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Brass Valve Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Brass Valve Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :42461597 Due date: 04 Nov, 202504 Nov, 2025 NA
Tender For scope of work (sow) as mentioned in tender and schedule of work( 25 )items as given below ,[1] check, maint, repr/repl of pumps, p/p 1.060 le,[2] check, maint, repr/repl of comprs, p/p 1.060 le,[3] repr/repl of damaged pipelines & valves 212.000 ea,[4] check, maint of crusher & associated job 1.060 le,[5] check, maint of d/as & softeners at p/p 1.060 le,[6] replacement of crusher 1.000 le,[7] disman., servicing & erection of valves 42.500 ea,[8] svcg,steam line vlv f/ejector 30.000 ea,[9] svcg,feed pump turbine 5.000 le,[10] techl descaling,boiler heating surface 205.000 std,[11] clng,oil tank&pump ovhlg 6.000 le,[12] ovhlg,lubg oil pump 7.500 ea,[13] ern of scaffolding 11.500 to,[14] svcg,condenser 7.500 ea,[15] disman,ovhlg,aligmtof pumps 12.000 ea,[16] svcg air suction sys : blwr 6.000 ea,[17] svcg of nrv , arv of blwr 6.000 ea,[18] svcg of drain tank etc of blwr 5.000 ea,[19] oil cooler tube rpr/replace of blwr 5.000 ea,[20] t/blwr valves rpr / replace 45.000 ea,[21] gauge glass and associated jobs t/blwr 14.000 ea,[22] painting of condenser etc for t/blwr 242.000 m2,[23] disman,existing pipe,ci 162.500 m,[24] ern,pipe line 140.000 m,[25] rprg,condenser 1.000 ea

corporations/Associations/Others

CTN :41764135 Due date: 04 Nov, 202504 Nov, 2025 11.92 Lacs
Tender For corrigendum : supply of miscellaneous control and instrumentation items for btps, obra. - lubricator air filter with pressure gauge max. inlet pr. 15kg/cm2 outlet pr. range: 0-10kg/cm2 connection: 3/4" npt, manual drain 40micron sintered bronze/ metal bowl filter element, lubricator air filter with pressure gauge max. inlet pr. 15kg/cm2 outlet pr. range: 0-10kg/cm2 connection: 3/4" npt, manual drain 40micron sintered bronze filter element, stub for steam line and w.o. outlet bfp (as per sample), thermowell for steam / water line and w.o. (as per sample), thermocouple k-type duplex with head l-400mm od-19mm, k- type thermocouple od-6mm l-320mm bsp (m), k- type without head connation thermocouple for boiler/ turbine metal temperature measurement l-15mtr, od-6mm, rtd (prt-100*ohm*) thermocouple type along with thermowell head connection 320mm, od-6mm duplex bsp, rtd (prt-100*ohm*) capsule type thermocouple along with thermowell head connection l-20mm, od-4mm, (20x10) & od-3mm (5 nos) duplex type m&f adjust, k- type thermocouple od-6mm l-400mm bsp (m), pa fan temp. switches 0-120 deg. c1. dial size: 150 mm normal dia, white back ground, black marking2. range: 0 120 c3. case: weather proof to ip: 65 as per is:13947, die cast aluminium, bezel ring4. stem: 10 mm dia in ss 316, total stem length-200 mm5. connection: 3/4" npt(m) gland table in ss3046. capillary: ss 304 covered, 10 meter long solid drawn7. accuracy: 1% of fsd for indication & 2% of fsd for switching8. over range: 120 % of fsd9. window: acrylic10. contacts: 2spst contact, both normal op to close on rise of temperature rated 30 va, 240 v ac., temperature switch: fd fan stem length 175mm, 0 120 deg. c with sleeve zero adjustment at outside the casing along with fitting.tech. specification: -1. dial size 100 mm nominal dia, white back ground, black marking.2. range 0 120 deg.c.3. case weather proof p: 65 as per is: 2147, die cast aluminium with screwed aluminium, bezel ring.4. stem 10 mm dia in ss 316, total stem length-175 mm.5. connection 1/2" npt (m) gland adjustable in ss304.6. capillary ss 304 covered + pvc coating, 03 meter long.7. accuracy of fsd for indication 2% of fsd for switching.8. over range 120 % of fsd.9. window acrylic.10.contacts 1spst contact, both normal open to close on rise of temperature rated 30 va, 240 v ac., temperature switch stem size 300mm for id fan temperature switch: stem length 300 mm, 0 120 deg. c with sleeve zero adjustment at outside the casing along with fitting.other tech. specification: -1. dial size 100 mm normal dia, white back ground, black mar 2. range 0 120 deg. c.3. case weather proof to ip: 65 as per is: 2147, die cast aluminium with screwed, bezel ring.4. stem 10 mm dia in ss 316, total stem length-300 mm.5. connection 1/2" npt (m) gland adjustable in ss304.6. capillary ss 304 covered with coating, 03 meter long.7. accuracy 1% of fsd for indication 2% of fsd for switching.8. over range 120 % of fsd.9. window acrylic.10. contacts 1 spst contact, both normal open to close on rise of temperature rated 30 va, 240 v ac, temperature switch stem size 150mm temperature switch: stem length 150 mm, 0 200 deg. c with sleeve zero adjustment at outside the casing along with fitting.other tech. specification:1. dial size 150 mm normal dia, white back ground, black marking2. rang 200 deg. c3. case weatherproof to ip: 65 as per is:2147, die cast aluminium with screwed, bezel ring4. stem 10 mm dia in ss 316, total stem length-150 mm5. connection 1/2" npt(m) gland adjustable in ss3046. capillary ss 304 covered with pvc coating, 03 met ng7. accuracy 1% of fsd for indication 2% of fsd for switching8. over range 120 % of fsd9. window acrylic10. contacts 1spst contact, both normal open to close on rise of temperature rated 30 va, 240 v ac, digital ind 4 digit dual channel 138x32mm, digital ind 4 digit single channel 138x32mm, 3 nos.)

State Government

CTN :41943265 Due date: 28 Oct, 202528 Oct, 2025 3.15 Lacs
Tender For corrigendum : supply of auto liquid drain trap for instrument airline in boiler, turbine and bop area at abvtps, cspgcl, janjgir-champa.

State Government

CTN :42236389 Due date: 29 Oct, 202529 Oct, 2025 NA
Tender For corrigendum : startup vent silencer drain line providing work in boiler 6 at tnpl unit i

corporations/Associations/Others

CTN :42292313 Due date: 28 Oct, 202528 Oct, 2025 NA
Tender For mtps i bm unit iii boiler pressure parts aoh 2025 inspection and rectification of worn out lines and bends of super heater header drain lines and allied works

CTN :42308807 Due date: 28 Oct, 202528 Oct, 2025 NA
Tender For mtps - i – bm – unit – iii - boiler pressure parts - aoh – 2025 – inspection & rectification of worn out lines & bends of super heater header drain lines, emergency blow down lines and ibd drain lines and removal of insulation and refixing over drain line pipes and bends after completion of work etc.
 Loading, Please wait...

Connect us via What's Up