Get complete information related to latest Breaker Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Breaker Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Breaker Scrap Tenders.
Tender For supply of mcb 60 a, 2 pole , 240 volt ac, (type -c) , 37 ka conforms to iec 60947-2, miniature circuit breakers as per is: 8828/moulded case circuit breaker
Tender For supply of repair and painting of volleyball court boundary wall 96x68x3 ft , repair of iron mesh fencing 10 x35 ft for 02 panels , 200 w led flood light , 2sqmm multi strand copper wire , miniature circuit breaker , on or off switch , 12 module surface box and plate , installation charges for electrical fitting and accessories
Tender For supply of loadster miniature circuit breaker single pole 003 , loadster miniature circuit breaker single pole 009 , loadster miniature circuit breaker single pole 0029 , loadster miniature circuit breaker single pole 0056 , loadster miniature circuit breaker single pole 0058
Tender For supply of 12v 120ah smf vrla battery , 12v 26ah smf vrla battery , 12v and 24 v selectable or auto adjustable battery charger , surge protection device , 6a ac miniature circuit breaker , 16a dc miniature circuit breaker , 3 core 1. 5 sq. mm ac power cable , 1 core 4 sq. mm dc power cable , rj 45 lan port surge protector , rf co axial surge protector for vhf frequency , 2. 5 sq. mm pure copper earthing cable , equi potential copper earth bar , n type male to n type female flexible coaxial cable , terminal block for dc connection , 3 pin male xlr connector , 3 pin female xlr connector , 3 meters rj45 cat6 patch cord , 20 meters rj45 cat6 patch cord , 16 port ethernet switch
Tender For supply of electrical consumable and other miscellanous items miniature circuit breaker 2 pole 16 amp, 240/415v single phase ac, 50 hz. , miniture circuit breaker mcb 32 amp, 2 pole, 10 ka, 240/415 volt ac , miniature circuit breaker 3 - pole, 32 a, 415 v , m.c.b.isi markd 32a, 415v ac 4 pole , m.c.b.isi markd 63a, 240/415v 4 pole , switch socket combined 6 & 16 amp.anchor make , plug socket 6 amp 230v,5 hole , ring type insulated copper terminal ends (lugs) for 2.5 sqmm cable, stud hole 5.2 mm , 2.5 sqmm crimping type , red oxide , self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm , width x 7.5 mtr length x 0.125 mm thickness, of red colour , self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm , width x 7.5 mtr length x 0.125 mm thickness, of yellow colour , self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm , width x 7.5 mtr length x 0.125 mm thickness, of blue colour , self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm. , width x 7.5 mtr length x 0.125 mm thickness. of black colour , self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm , width x 7.5 mtr length x 0.125 mm thickness. of green colour , oil stop leak putty 114 gms. pack , led down/panel light 20 watt, square white color 240 volt
Tender For e.i for setting up of work station system in the audit branch of administrative office in p.u campus, sector-14, chandigarh - wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. frls/hffr pvc insulated copper conductor single core cable etc. as required (dsr 1.8), group c (dsr 1.8.3), rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable and 1.5 sq.mm frls/hffr pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required (dsr 1.15), group c (dsr 1.15.3), supplying and drawing following sizes of frls/hffr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required (dsr 1.17), 3 x 2.5 sq. mm (dsr 1.17.12), 3 x 4 sq. mm (dsr 1.17.21), supplying and drawing following sizes of frls/hffr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required (dsr 1.21), 25mm (dsr 1.21.2), supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required (dsr 1.22), 75 mm x 75 mm x 60 mm deep (dsr 1.22.1), supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required (dsr 1.24), 5/6 a switch (dsr 1.24.1), 3 pin 5/6 a socket outlet (dsr 1.24.4), supplying and fixing following modular base & cover plate on existing modular metal boxes etc. as required. (dsr 1.28), 3 module (dsr 1.28.2), 6 module (dsr 1.28.4), 8 module (dsr 1.28.5), supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 a modular socket outlet and 5/6 a modular switch, connections etc. as required (dsr 1.31), supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required (dsr 1.32), supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (dsr 2.4), 4 way (4 + 12), double door (dsr 2.4.1), supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.(dsr 2.10), single pole (dsr 2.10.1), supplying and fixing dp sheet steel enclosure on surface/ recess along with 25/32 a 240 v "c" curve dp mcb complete with connections, testing and commissioning etc. as required. (dsr 2.16, providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. (dsr 5.18), supplying, drawing, installation, testing and commissioning of cat6a utp 4 pair, 23 awg solid copper cable in existing conduit/ on surface, u/ftp, lszh, non-plenum, horizontal (solid) cable suitable for high speed data networking application supporting upto 10gbps over a 100 meter channel. the 4 unshielded twisted pairs (utp) cable with color coded insulation for easy indentification should have flame properties i.e. flammability test - iec 60332-1, smoke density - iec 61034, lszh standards compliance: ansi/tia- 568 c.2, iso/iec 11801