Web Analytics Made Easy - StatCounter

Breast Wall Tenders

Get complete information related to latest Breast Wall Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Breast Wall Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Breast Wall Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government / Public Sector

CTN :45478545 Due date: 04 Jul, 202604 Jul, 2026 1.17 Crore
Tender For corrigendum : tender for supply of electrical consumable and miscellaneous items for hurl sindri c - cable tie, lock type cut to open, colour-white, thickness-2.5mm, length-100mm, material nylon 66, pack size 100. cable tie, lock type cut to open, colour-white, thickness-2.5mm, length-200mm, material nylon 66, pack size 100. cable tie, lock type cut to open, colour-white, thickness-2.5mm, length 300mm, material nylon 66, pack size 100. electrical contact cleaner spray, quick dry, packing size for liquid(ml)-500ml galvanized zinc spray, finish type-bright silver, zinc-enriched coating to repair surface damage protection against corrosion, special feature-rust resistance, packing size for liquid(ml)-500ml. silica gel, colour of silica gel-blue, particle size -9 to 12 mm, air tight container for packing of silica gel-plastic. silicon sealant, physical state- viscous paste, appearance-translucent/ opaque, color-clear/black/white/gray, surface cure-5-10 min, packing size(ml)-300ml m-seal, shelf life 12 months, hardness 75-80, impact strength - 2.5 * 3kg / c * m setting time at 30 deg c min-60 min, working temp limit 80 deg. c component resin and hardness, packaging size-1 kg gap filling pu foam spray(puf seal), application fill the gap between wall & tray, conduit pipe and wire sealing, packing size for liquid(ml)-750ml. silicon sealant gun, feed type: push-fed gun, type: cordless-corded glue gun pvc tape, material pvc, adhesive-rubber bases adhesive, adhesive side- single side, temperature range (-40 degree c to 125 degree c), colour red, length-6.5 mtr, voltage resistance- upto 600v. pvc tape, material pvc, adhesive- rubber bases adhesive, adhesive side- single side, temperature range (-40 degree c to 125 degree c), colour yellow, length 6.5 mtr, voltage resistance-lipto 600v. pvc tape, material-pvc, adhesive- rubber bases adhesive, adhesive side-single side, temperature range (-40 degree c to 125 degree c), colour blue, length 6.5 mtr, voltage resistance-upto 600v pvc tape, material -pvc, adhesive rubber bases adhesive, adhesive side- single side, temperature range(-40 degree c to 125 degree c), colour-black, length 6.5 mtr, voltage resistance- upto 600v. pvc tape, material pvc, adhesive-rubber bases adhesive, adhesive side- single side, temperature range (-40 degree c to 125 degree c), colour green, length 6.5 mtr, voltage resistance upto goov ht-tape, self bonding electric tape, for high-voltage(upto 69kv), corona and ozone resistant, moisture and corrosion resistant, overload temperature 130 deg. c. roll size 9.15 meters. teflon tape, packing type-piece, elongation % 50-60, length of tape-9 mtr, application of colour tape white al foil tape, color-sever, type-aluminium foil tape 2 inch, cello tape type single sided, tape dispenser type-high bond, self adhesive, cello tape roll size-15 meters waste cotton doth emery paper, grit size grit 40-60, material emery, form-belt, bonding type-resin, coat type-open coat, suitable material mild steel, stainless steel. roll length-40 inch. emery paper, grit size-grit 220-400, material-emery, form-belt, bonding type-resin, coat type-open coat, suitable material mild steel, stainless steel roll length 280 mn trubble gum, strong glue trap, type- glue board, container type-sachet, protection against-rats titanium putty, 1 kg 1.5 sq.mm ring type lug, insulated type, rated voltage-upto 1100v, material copper, minimum pack of 200 2.5 sq.mm ring type lug, insulated type, rated voltage-upto 1100v, material copper, minimum pack of 100 4 sq.mm ring type lug, insulated type, rated voltage-upto 1100v, material-copper, minimum pack of 10 1.5 sq.mm pin type lug, insulated type, rated voltage-upto 1100v, material-copper, minimum pack of 200 2.5 sq.mm pin type lug, insulated type, rated voltage-upto 1100v, material copper, minimum pack of 20

State Government

CTN :45731679 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For restoration of rain damages on bhalad chaniyala theru karsoli dharoon road km 0/00 to 7/500 (s.h:- construction of breast wall at rd 4/435 to 4/450)

State Government

CTN :45731791 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For restoration of rain damages on bhalad chaniyala theru karsoli dharoon road km 0/00 to 7/500 (s.h:- construction of breast wall at rd 4/435 to 4/450)

State Government

CTN :45731845 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For restoration of rain damages on mastgarh mandole behi pathiar 24 mile road km 0/0 to 12/200 (s.h:-construction of breast wall at rd 2/435 to 2/446.80)

Central Government/Public Sector

CTN :45713850 Due date: 11 Jul, 202611 Jul, 2026 27.00 Lacs
Tender For repair/replacement to doors, window, ventilators, cupboards, flooring/ plastering, tilling and other miscellaneous joinery /sanitary items at af stn aastha complex, 5 aflu under aor of ge (af) faridabad - demolition/dismantling of brickwork or stone/ boulder masonry, built in cement mortar incl all quoins, arches, pillars, etc, complete all as specified and directed., m&l for brickwork with subclass b bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in cm 1:6 complete all as specified and directed., all as per item no 02.00 above but except bricks., m&l for brick work with sub class b bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in cm 1:4 complete all as specified and directed., taking down cement plaster of any description on concrete surfaces such as soffit of rcc slab, chajjas and brick walls, ceiing etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed., m&l for rendering 15 mm thick cement plaster in cm 1:6 on brick work or concrete surfaces including finished even and smooth without using extra cement complete all as specified and directed., m&l for rendering 15mm thick in cm 1:4 on of brick work or concrete surface finish ever and smooth (w/o using extra cement) incl wpc as per user manual complete all as specified and directed., m&l for rendering 10mm thick in cm 1:3 over concrete surface as on ceiling, chajja, shelves etc to match with existing surfaces finish even and smooth w/o using extra cement complete all as specified and directed., m & l for preparation of new plastered surface and applying two coats of oil emulsion distemper on wall over one coat of primer incl one layer of 3mm thick wall care putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed., m&l for preparation of new plaster surface & apply two coats of cement based paint over a coat alkali primer resistance incl one layer of 3mm thick wall care putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed., m & l for preparation of new plastered surface and applying two coats of oil emulsion distemper on ceiling over one coat of primer incl one layer of 3mm thick wall care putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed., taking down chowkhats or frames with shutters not exc. 1.5 sqm each (without taking off shutters from the frames) complete all as specified and directed., taking down chowkhats or frames with shutters exc 1.5 sqm but not exc. 4 sqm each (without taking off shutters from the frames) complete all as specified and directed., taking down shutters of any description n exc 1 sqm each complete all as specified and directed., taking down shutters of any description exc 1 sqm and n exc 2 sqm each complete all as specified and directed., s&f for 30mm thick flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides and one face is covered with decorative face veneer with lipping/frame to match complete all as specified and directed., s & f solid pvc door frame of size 50 x 47 mm made out of 5 mm plain colour pvc sheet reinforced with ms square tube incl taking down old frame any type complete all as specified and directed., s&f factory made solid panel pvc door shutter 30 mm thick (style) consisting of frame made out of ms tubes for top & bottom rails ms frame shall be convered with heat moulded plain colour pvc `c channel having a pvc sheet strip of 20 mm width stuck inside with solvant cement for stiles and plain colour pvc sheet top rail, lock rail and bottom rail on either side and as gap insert of top rail and bottom rail; paneling of plain c

Central Government/Public Sector

CTN :45709067 Due date: 18 Jul, 202618 Jul, 2026 45.00 Lacs
Tender For repair replacement of internal wiring incl sub main wiring, mcb dbs, bldgs security lights and connected items in pocket 1 to 8 under ge roorkee - taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed., m&l for point wiring with 1.5 sqmm frls-h insulated, unsheathed, multistranded, 1100 volts grade copper conductor cable single core conforming to is:694 along with one run of 1.5 sqmm frls-h insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories / junction boxes / inspection covers etc of suitable size but not less than 20mm(od), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass gi screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., all as per item no 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch., all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one one light point controlled by two no. two way switch complete all as specified and directed, all as per item no. 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., m&l for sub main wiring along with earth wire with frls-h insulated copper conductor, single core cable drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(ph & n) + 1run x 4 sqmm(earth wire):- (note: three runs of copper cable and one run of pvc conduit shall be measured as one unit length), all as per item no 11 here-in-before but 2runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), all as per item no 11 here-in-before but 2runs x 10 sqmm(ph & n) + 1run x 10 sqmm(earth wire), all as per item no 11 here-in-before but 4runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), notes for item no. 2.00 to 14.00(i) quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) if any beam / column / rock wall is encountered while cutting chases, that particular portion may be provided with pvc casing & capping or surface conduit for drawing cables and surface pvc gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) no cutting shall be done on ceiling for laying pvc conduit for ceiling fan point wiring. surface conduit or pvc casing capping may be

Central Government/Public Sector

CTN :45711072 Due date: 20 Jul, 202620 Jul, 2026 36.87 Lacs
Tender For special repair to dbs sub main wiring and miscellaneous items at mh and central institute at old amritsar cantt - taking down copper/ aluminium point wiring (light, fan, socket or power) complete including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody or for taking credit (creit for above items shall be made as per condtitions separately) and making good disturbed surface of walls, floors, etc complete all as specified and directed., material and labour for point wiring in existing conduit for following point controlled by one switch ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core frls pvc insulated unsheathed and multi stranded copper conductor cable 1100 volt ( isi marked ) drawn through and existing pvc concealed/conduit with all fittings and accessories including pressed steel powder coated sunken terminal box suitable for modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core frls pvc insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including necessary cutting chases in wall and making good disturbed surfaces of walls/ceiling/floorsetc by using cement mortar (1:3) complete all as specified and as directed. note : 1 switch, socket, regulator, bell, ceiling rose, regulator, lamp holder will be measured and paid separately.a) for one light /fan/ buzzer point controlled by one 5 amp switch one way, b). for one three pin socket outlet 5 amps independent board., c) for one three pin 5 amps socket outlet on the same board with other switch, d) for one light point controlled by two way switch, all a per item no 2 here-in-above but with 2.5 sq mm size cable multi stranded frls copper wire unsheathed for one 3 pin socket outlet 15 amps on independent board including continuous earth wire of pvc insulated 2.5 sq mm copper multi stranded conductor connecting to common earth dolly complete all as specified and directed., material and labour for surface point wiring for one light point/fan point/bell point controlled by one switch ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core frls pvc insulated unsheathed and multi stranded copper conductor cable 1100 volt ( isi marked ) drawn and including surface pvc conduit with all fittings and accessories i.e. pipe bend,pipe hook, elbow,juction boxes etc including pressed steel powder coated sunken terminal box suitable for modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core frls pvc insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including necessary cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc by using cement mortar (1:3) complete all as specified and as directed. note : 1. switche, socket, regulator, ceiling rose, bell, lamp holder will be measured and paid separatelya) for one light /fan/ buzzer point controlled by one 5 amp switch one way, b). for one three pin socket outlet 5 amps independent board, c) for one three pin 5 amps socket outlet on the same board with other switches, d) for one light point controlled by two way switch, all a per item no 7 here-in-above but with 2.5 sq mm size cable multi stranded frls copper wire unsheathed for one 3 pin socket outlet 15 amps on independent board including continuous earth wire of pvc insulated 2.5 sq mm copper solid conductor connecting to common earth dolly complete all as sp

Central Government And Public Sector

CTN :45725908 Due date: 20 Jul, 202620 Jul, 2026 17.65 Lacs
Tender For painting of building, repairing of plinth surface, drain and roof surface, protection wall, chain link fencing with miscellaneous repair works of project hospital at rangit power station

State Government

CTN :45719414 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For recovery and reconstruction of tikar jarol gahan nankhari khamadi road km 0.000 to 52.000 sub head construction of r.wall at rd 23.875 to 23.895 24.300 to 24.310 27.705 to 27.720 and breast wall at rd 28.030 to 28.050 under pdna

State Government

CTN :45719417 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For restoration of rain damages on nankhari to sharog shakla to barog road km 0.000 to 3.000. sh c.o breast wall from km 1.235 to 1.242.
 Loading, Please wait...

Connect us via What's Up