Get complete information related to latest Brick Aggregate Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Brick Aggregate Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Brick Aggregate Tenders.
Tender For supply of materials for mgnrega works - supply of materials, earth, coal (steam), carriage of tar bitumen, bitumen vg-30, bitumen emulsion, stone screening type a (13.2 mm), stone screening type b (11.2mm), stone screening type a (13.2 mm), coarse sand, stone aggregate(single size): 06 mm nominal size, grade 1 stone metal 63 mm to 45 mm, 1st class picked jhama bricks(traditional), 1st class bricks, coarse sand, stone boulder ( 225mm-150mm ), coloured inter locking c.c. paver block, fine sand, silver sand, portland cement, stone aggregate(single size):20 mm nominal size, stone aggregate(single size): 10 mm nominal size, loading unloading & stacking sand/ stone aggregate (less than 40mm nominal size), stone aggregate(single size): 40 mm nominal size, precast cement concrete blocks (nominal mix. 1:1.5:3 with 20 mm down coarse aggregate including supplying at site, laying and finishing the top surface with 1:3 cement mortar), medium sand, udaypur marble slab ( for floor, lobby etc) 18 mm thick of size 0.3 sq m to 0.6 sq m, chawk dungri marble slab ( for floor, lobby etc) 18 mm thick of size 0.3 sq m to 0.6 sq m, udaypur marble slab ( for wall/dado) 18 mm thick of size 0.3 sq m to 0.6 sq m, chawk dungri marble slab ( for wall/dado) 18 mm thick of size 0.3 sq m to 0.6 sq m, ceramic glazed tiles ist quality 300 x 300 mm in all shades and designs of white, ivory, grey, fume red brown etc., rectified - ceramic glazed tiles ist quality 300 x 300 mm or more in all shades designs white, ivory, grey, fume red brown etc, vitrified floor tile 60x60 cm, precast chequered cement tiles 22 mm thick dark shade using ordinary cement, hire charges of concrete mixer 0.25 to 0.40 cum with hopper, vibrator (needle type 40 mm), water tanker 5000 ltr. capacity, r.c.c. pipes np2 class 300 mm dia, r.c.c. pipes np2 class 450 mm dia, rcc pipe 600 mm dia np- 3 spigot, carriage of r.c.c. pipes 600,700,750 & 800 mm dia, loading, unloading & stacking by manual means (r.c.c. pipes , c.i. pipes and unreinforced cement pipes) 600, 700, 750 & 800 mm dia, rcc pipe 900 mm dia np - 3 spigot, carriage of r.c.c. pipes 900 mm dia, loading, unloading & stacking by manual means (r.c.c. pipes , c.i. pipes and unreinforced cement pipes) 900 mm dia, empty gunny bag, bamboo (8cm-10cm dia) including fixing, nail, sal bullah (7.5cm -10cm dia), eucalyptus bullah (7.5cm -10cm dia), sal bullah (12.5cm -15cm dia), sal bullah (17.5cm -20cm dia), eucalyptus bullah (7.5cm -10cm dia), eucalyptus bullah (12.5cm -15cm dia), eucalyptus bullah (17.5cm -20cm dia), sausage wire net, galvanised steel corrugated sheets, galvanised steel bolts & nuts 6 mm dia and 25 mm long round head with slots, galvanised steel j or l hooks 8 mm dia, false ceiling (with 4mm thick pearl designer fibre cement board), supplying, fitting & fixing asbestos corrugated sheet(6 mm thick), supplying, fitting & fixing asbestos ridging, supplying, fitting & fixing zn-al alloy steel sheet work in roof, supplying, fitting & fixing aluminium sheet ridging, fitting and fixing glass reinforced polyester translucent fiber glass sheet, fitting and fixing glass reinforced polyester translucent ridging, fitting & fixing circular corrugated aluminium sheet, tor steel rods/hysd bars/tmt bars(jsw/jspl/shyam/srmb/bmasl/elecrosteel/ssl)(fe415/fe500/fe500d conforms to is: 1786), tor steel rods/hysd bars/tmt bars (other than sail/tata/rinl/jsw/jspl/shyam/srmb/bmasl/elecrosteel/ssl)(fe415/fe500/fe500d conforms to is: 1786), brickaggregate (single size):40 mm nominal size, moorum, stone aggregate(single size):63 mm nominal size, river bed material, geotextile 120 gram per sqm membrane, hire charges of shuttering plank (25mm-30mm thick) with prop including all fittings, hire charges of shuttering plank (25mm-30mm thick) without prop including all fittings, hire charges of shuttering plank (above 30mm-37mm thick) with prop including all fittings, thermocol 12.5 mm thick., polythene sheet (150 gm
Tender For supply of dry chemical powder , clip jubilee 3 and half to 4 1 by 8 , emery cloth abrasive cloth is grit 36 , cloth coated pvc 102 cm wide , paint roller 6 inch , paint brush 4 inch , paint brush 2 inch , gloves leather a , detergent solution , grease lg 280 , cleaner white toilet , paint roller 9 inch , ear plug , switch socket 3 pin 15a isi mark , rope polypropylene 16 mm isi mark , broom country , super mop , tape transparent 1 inch , sand paper isi mark , paint roller 7 , paper napkin , dvd , envelope cloth coated 12x16 inch , envelope cloth coated 10x14 inch , envelope cloth coated 9x12 inch , tape transparent 2 inch , tape insulating 25 mm , wonder tape 2 inch , wet surface putty , xerox paper 80 gsm 420 x 297 mm a3
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl
Tender For corrigendum : e-tender for civil contract jobs - civil contract job:, earth filling under floors with surplus ordinary soil or soil containing gravel or kankar, including ramming, watering and consolidated lead., first class burnt brick work laid in cement sand mortar 1:7 in foundation and plinth, laying 80 mm thick factory made cement conc. inter locking paver bricks after m-40 grade made by block making machine with string vibratory compaction ordinary gray color & pattern over 50 mm thick compacted bed of coarse sand filling the joint with fine sand, complete in all respect ., dismantling brick of flagged stone flooring including concrete base, dismantling concrete plain 1:2:4 mix, cement concrete 1:2:4 with stone ballast or shingle, a. mixing by manual mean, b. mixing by mechanically mean using concrete mixer, laying of dry brick ballast 40mm gauge for flooring, civil work (rate to quoted on csr rates)
Tender For corrigendum : repair to security lights panels dg sets fire alarm ups with covered items at af stn bikaner under ge (af) nal - excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m depth, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed by engineer-in-charge., removal of excavated material soils to a distance n exc 50 m and depositing where directed at a level not exceeding 1.5m above the startly point complete all as specified and directed., returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm as in any type of soil complete all as specified and directed., material and labour for sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed. note : punned thickness shall be measured for payment., material and labour for un-reinforced pre-cast concrete cable covers, class lv type-1, flat size 250mm x 150mm x 40mm thick complete all as specified and directed., taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 6 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 10 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 4 core, 16 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 25 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 35 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 50 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 6 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge , supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 10 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 4 core 16 sqmmlaid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 3.5 core 25 sqmm laid in trenches
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking
Tender For supply of jerry can 20 ltrs , hand sanitizer , air freshener or air pocket 10 in no pkt , tube florescent or led or cfl , lamp cfl or led 20 watt , corrosion inhibitor 750 ml , can plastic 10 ltr capacity , varnish , polythene film length 112 width 18 thk 0.007 , bag gunny 27 x 21 , paint finishing for inter deck white , paint rfu priming red lead , paint coal tar epoxy black , paint remover non-inflammable , rope polypropylene 16 mm isi mark , emery cloth abrasive 11 x 9 is grit 36 , cloth terry flex cotton 36 width , cloth flanet 4 by 2 , cloth coated pvc 102cm wide , roller paint 6 inch , gloves leather v , emery cloth abrasive cloth is grit 36 , detergent solution , bleaching powder stabilised , dry chemical powder 05 kg pack , battery charger with connecting lead ma4234 for sse , grease lg 200 , aluminium telescopic baton size 3 mtr , clip jubilee 3.5 , jubilee clip 1 and half inch , twine sewing plastic , super mop , sand paper , safety glasses or goggles , o ring cord 7mm , ear plugs , anti corrosive compound 750 ml pack , instant glue 1 ltr pack * /bid number : gem/2026/b/7717654 + /dated: 27-06-2026 ' ' / bid document 1 / 28
Tender For corrigendum : fixation of local market rate for implementation of different scheme under mgnrega under sainthia development block - lmr, hire charges of concrete mixer with fuel 0.25 to 0.40 cum with hopper, hire charges of diesel road roller with fuel- 8 to 10 tonne, vibrator with fuel (needle type 40 mm), surface vibrator with fuel, water tanker 5000 ltr. capacity, coolie, fitter(grade1), technician, helper (technician), seam bolts and nuts 6 mm dia and 25 mm long, brickaggregate (single size):50 mm nominal size, brickaggregate (single size):40 mm nominal size, stone aggregate(single size):63 mm nominal size, stone aggregate(single size): 40 mm nominal size, stone aggregate(single size):20 mm nominal size, stone aggregate(single size): 10 mm nominal size, stone aggregate(single size): 06 mm nominal size, coal tar, portland cement, white cement, coal (steam), brass 150 mm floor door stopper (0.357 kg), chromium plated brass mortice latch and lock 100x65 mm with 6 levers and a pair of brass lever handles, glue, unslaked lime, synthetic enamel paint, having voc ( volatile organic compound content less than 150 gm/liitre, ready mixed pink or grey primer on wood work(hard and softwood) having voc content less than 50 gms/litre, water thinnable cement primer for interior wall surface, having voc content less than 50 gms/litre, moorum, black japan, synthetic enamel paint in black or chocolate shade, superior copal varnish, green or blue medium shade pigment, rolling shutter made of 80x1.25 mm machine rolled laths, galvanised steel plain sheets, galvanised steel bolts & nuts 6 mm dia and 25 mm long round head with slots, galvanised steel j or l hooks 8 mm dia, g.i limpet washer, bitumen washer, g.i. plain washer for seam bolts, water proofing materials, welding by electric plant, wire mesh (rabbit), diesel oil, c.i. grating 100x100 mm, mirror of superior make glass 60x45 cm, vitreous china pedestal for wash basin, gi pipes 15 mm dia, gi pipes 20 mm dia, gi pipes 25 mm dia, gi pipes 32 mm dia, gi pipes 40mm dia, gi pipes 50 mm dia, gi pipes 65 mm dia, gi pipes 80 mm dia, slotted cowl 75 mm, slotted cowl 110 mm, polyethylene water storage tank with cover and suitable locking arrangemnet, r.c.c. pipes np2 class 300 mm dia, r.c.c. pipes np2 class 450 mm dia, white plastic seat (solid) with lid c.p. brass hinges and rubber buffers, shower rose c.p brass for 15 to 20 mm inner 100 mm dia, shower rose c.p.brass for 15 to 20 mm inner 150 mm dia, vitreous china squatting plate, ball valve 15 mm dia, ball valve 20 mm dia, ball valve 25 mm dia, brass full way valve with c.i. wheel (screwed end) 20 mm dia, vitreous china flat back wash basin 630x450 mm, vitreous china angle back wash basin 400x400 mm, vitreous china foot rest 275mmx125mmx25mm, carriage of steam coal, carriage of stone aggregate below 40 mm nominal size, carriage of steel, carriage of stone aggregate 40 mm nominal size and above, carriage of tar bitumen, carriage of soling stone & masonry stone, carriage of carriage of moorum, float glass sheet of nominal thickness 4 mm (weight not less than 10 kg/sqm), float glass sheet of nominla thickness 5.5 mm (weight not less than 13.50 kg/ sqm), float glass sheet of nominal thickness 8 mm (weight not less than 20.00 kg/sqm), anodised aluminium hanging type door stopper, carriage of cost of neelgiri/maxican grass truf sqm, galvanised steel corrugated sheets, vitreous china flat back wash basin 550x400 mm, stainless steel bolts /square bar and plates, mild steel tubes hot finished seamless type, red oxide zinc chromate primer, vitreous china flat back wash basin 450x300 mm, hydraulic door closer tubular type aluminium section body, oxidised m.s. casement stay (straight peg type) 300 mm not less than 0.33 kg, coloured orissa pattern w.c. pan 580x440 mm, coloured pedestal type w.c. pan 580x440 mm (european type) p trap, circular shape 450 mm dia precast r.c.c. manhole cover with frame l.d. -25, upvc pipes (working pressure 4 kg /cm2
Tender For providing, lowering, laying, cutting (cut surface to be uniformly finished), jointing with rubber rings marked with is : 5382 and testing of spigot and socketted rcc, np2 marked with is : 458-1988 and specials into trenches for all depths including carriage, loading, unloading, stacking, handling, re-handling etc. complete is all respects to the satisfaction to the engineer - in -charge. 4. 350 mm i/d ,`jointing plain and reinforced concrete pipes and specials of all classes in trenches using collar joints jointed with 1:1 cement sand mortar nearly dry heavily caulked into joints and with end dowels filled with 1:1 cement sand mortar including facing trowelling and finishing the joints at an angle of 45 degrees with faces of collars keeping joints wet till curved testing the drain lines for leakage and making good all leakage and defects as laid down in the contract specifications complete with two spigot ends jointed to collar and internal diameter of sewer pipe or special , earth work in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by engineer-in-charge. 1. all kinds of soil ,cement concrete (cast in situ) providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work below plinth level and up to floor iv level: 3. 1:2:4 (1 cement : 2 coarse sand (zone-iii) : 4 graded stone aggregate 40 mm nominal size),brick work brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 2. cement mortar 1:6 (1 cement : 6 coarse sand), cement plaster (in fine sand) 12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand)