Get complete information related to latest Brick Ballast Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Brick Ballast Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Brick Ballast Tenders.
Tender For e-tender for civil contract jobs - civil contract job:, earth filling under floors with surplus ordinary soil or soil containing gravel or kankar, including ramming, watering and consolidated lead., first class burnt brick work laid in cement sand mortar 1:7 in foundation and plinth, laying 80 mm thick factory made cement conc. inter locking paver bricks after m-40 grade made by block making machine with string vibratory compaction ordinary gray color & pattern over 50 mm thick compacted bed of coarse sand filling the joint with fine sand, complete in all respect ., dismantling brick of flagged stone flooring including concrete base, dismantling concrete plain 1:2:4 mix, cement concrete 1:2:4 with stone ballast or shingle, a. mixing by manual mean, b. mixing by mechanically mean using concrete mixer, laying of dry brickballast 40mm gauge for flooring, civil work (rate to quoted on csr rates)
Tender For corrigendum : 15/edc(blp)/2026-27 - loading, unloading and safe cartage of the following materials from electricity store centre, balrampur to the work site/dump site (distance up to 50 km), st poles (11 mtr long), pcc poles (8.5 mtr long), acsr weasel conductor, lt abc 3x120+1x95+1x16sq.mm., 100 kva t/f, other line materials, erection of single st poles (11 mtr long) for 11 kv/l.t. line alongwith fitting of all accessories on pole including dragging of pole from dump site to pit site, erection of single pcc poles (8.5 mtr long) for 11 kv/l.t. line alongwith fitting of all accessories on pole including dragging of pole from dump site to pit site, erection of sectional double pole sectional pcc pole (8.5 mtr long pcc pole) alongwith fitting of all accessories on pole including dragging of pole from dump site to pit site., earthing of pole as per uppcl/resspo norms.., erection and grouting of stay sets alongwith complete fittings. cement, sand & brickballast provided by the contractor at his own cost., grouting of poles with 1:4:8 cc ratio of cement, sand & brickballast, backfilling of pits with mud completely.all required materials provided by the contractor at his own cost., laying, stringing, sagging & binding of conductors of 11 kv in 3 phase, 3 wire line with jumpering (where as required), laying, stringing & sagging of 3x120+1x95+1x16sq.mm. abc cable up to proper sag for the following size cable, construction of 11/0.4 kv s/s for 100 kva t/f with mounting and fitting of t/f on plinth/double pole with proper fitting of all acessories and connecting with all circuit including earthing of t/f fitting with all accessories., earthing of distribution t/fs for body & neutral upto water level with gi pipe of 1.5" dia. including gi strip size 35x6 mm. (all material will be supplied by contractor)., decentralized materials:-providing and fixing of following materials as per sanctioned estimate/package as per resspo u.p.p.c.l. drawing/ norms.(where is required)., suspension clamp with i hook, i hook, suspension clamp with i hook, i hook, lt fuse set., lt pvc cable al 1x120sq.mm., lt pvc cable al 1x400sq.mm., lug sutable for 250 kva, suspension clamp with i hook, i hook, lt fuse set., lt pvc cable al 1x120sq.mm., lt pvc cable al 1x400sq.mm., lug sutable for 250 kva
Tender For supply of materials and erection for shifting of control room pannel at 33/ 11 kv sub station bharsawa distt. kaushambi under deposit scheme on "semi turnkey basis" under edc, kaushambi - name of work: supply, carriage & erection of materials for control room pannel shifting of shiffting of 33/11 kv s/s bharsawa distt. kaushambi, supply of de-centralised materials, 11 kv 3x120 mm2 xlpe cable jointing kit o/d & i/d, control cable 4x2.5 mm2, control cable 2x2.5 mm2, g.i. pipe 6 " dia, rubber matting, clamp with nut & bosts, earth wire clamp for pcc pole, stay clamp for pcc pole, top channel clamp pcc pole, dropper channel clamp pcc pole, g.i. strip 35x6 mm, carriage of following material, pcc pole 8.5 mtr. long., structure of la, 33kv isolator, 33 kv cts, single t/f control pannel, 33kv vcb,11 kv outgoing. incoming pannel, battery & battery charger and other associated accessiories etc. (availibility at concern store center of store division), erection work, installation of 33 kv single transformer control pannel 2 no., incoming 2 no. and 7 no. outgoing in the switchgear room and grouting the pannel by rag bolt using cement, sand mortar in ratio 1:3. work includs fitting of all accessories in all respect with complete connection of control cable with pannel. all material will be provided by the contractor except vcb and crp., construction of cable trenchs with top cover and laying of control cable for vcb, c.t. & t/f control pannel etc. as per direction of engineer. trenchs to be 12 wide and 9 deep. work includes digging, of trench, concreting of the foundation in the ratio 1:3:6 r.b. wall 9 wide with cement mortar 1:4 and plastering inside the trench in the ratio 1:3 and sand filling in the trench. all material will be provided by the contractor., earthing of 11 kv indoor equipments, switchgears as per resspo drawing. with g.i. strip of size 35x6 mm. g.i. strip fully welded at both ends and to be connected with earthmat,, erection of dp with pcc pole 8.5 mtr long with all accessaries and grouting of the pcc pole with cement, sand and brickballast ratio 1:4:8 size 0.45x 0.45x 1.5 mtr deep under the ground as per drawing no. res-6.(cement, sand, brick, ballast shall be provided by the contractor.), installation of 24 volt battery and battery charger with cabinet in the switch gear room, by grouting base channel 100 x 50 x 6 x 1000mm. fixing of rag bolt., laying of 11 kv 3x300/3x185/ 3x120 sqmm. xlpe cable by digging 0.75 mtr. deep trench, putting layer of sand in the bottom, ramming it, laying of cable over it rmt and covering the cable from sides and top by laying bricks, finally covering the same by earth and levelling of the same, all the materials, except cable, will be pvovided by the contractor., fixing and termination of outdoor/ indoor heat shrinkable cable boxes of size 3 x300/3x185/3x120 sqmm. xlpe cable. boxes will be supplied by the contractor, sundries ( as per site requirement/emergency work), safe dismantling of 11 kv o/g pannel & received back to store, laying of weasel conductor with the help of aluminium roller by hanging three nos. on each support in a manner taking sufficient care to ensure safety of weasel conductor against rubbing on ground, precaution for safety of crops is also to be taken. the work includes jointing of conductor by providing jointing sleaves, stringing of conductor upto correct sag and binding of conductor with insulators on each support. all material shall be provided by contractor such as jointing sleeve binding wire, armour rod etc.
Tender For supply of materials and erection for shifting of control room pannel at 33/ 11 kv sub station bharsawa distt. kaushambi under deposit scheme on turnkey basis under edc, kaushambi - name of work: supply, carriage & erection of materials for control room pannel shifting of shiffting of 33/11 kv s/s bharsawa distt. kaushambi, supply of centralised materials, 11 kv switch gear 600/300/5a 350 mva i/c, 11 kv switch gear 200/100/5a 350 mva o/g, 11 kv 3x300 mm2 xlpecable, 11 kv 3x120 mm2 xlpecable, 24 volt battery, 24 volt battery charger, pcc. 8.5 mtr. long for feeder, 11 kv tpmo switch with fixing clamp, 11 kv top channel, 11 kv dropper angle, earthing complete, stay set complete, 11 kv polymer pin insulator, 11 kv polymer disc insulator, 11 kv disc fiting, 33 kv control panel t/f, acsr weasel conductor, supply of de-centralised materials, 11 kv 3x120 mm2 xlpe cable jointing kit o/d & i/d, control cable 4x2.5 mm2, control cable 2x2.5 mm2, g.i. pipe 6 " dia, rubber matting, clamp with nut & bosts, earth wire clamp for pcc pole, stay clamp for pcc pole, top channel clamp pcc pole, dropper channel clamp pcc pole, g.i. strip 35x6 mm, carriage of following material, pcc pole 8.5 mtr. long., structure of la, 33kv isolator, 33 kv cts, single t/f control pannel, 33kv vcb,11 kv outgoing. incoming pannel, battery & battery charger and other associated accessiories etc. (availibility at concern store center of store division), erection work, installation of 33 kv single transformer control pannel 2 no., incoming 2 no. and 7 no. outgoing in the switchgear room and grouting the pannel by rag bolt using cement, sand mortar in ratio 1:3. work includs fitting of all accessories in all respect with complete connection of control cable with pannel. all material will be provided by the contractor except vcb and crp., construction of cable trenchs with top cover and laying of control cable for vcb, c.t. & t/f control pannel etc. as per direction of engineer. trenchs to be 12 wide and 9 deep. work includes digging, of trench, concreting of the foundation in the ratio 1:3:6 r.b. wall 9 wide with cement mortar 1:4 and plastering inside the trench in the ratio 1:3 and sand filling in the trench. all material will be provided by the contractor., earthing of 11 kv indoor equipments, switchgears as per resspo drawing. with g.i. strip of size 35x6 mm. g.i. strip fully welded at both ends and to be connected with earthmat,, erection of dp with pcc pole 8.5 mtr long with all accessaries and grouting of the pcc pole with cement, sand and brickballast ratio 1:4:8 size 0.45x 0.45x 1.5 mtr deep under the ground as per drawing no. res-6.(cement, sand, brick, ballast shall be provided by the contractor.), installation of 24 volt battery and battery charger with cabinet in the switch gear room, by grouting base channel 100 x 50 x 6 x 1000mm. fixing of rag bolt., laying of 11 kv 3x300/3x185/ 3x120 sqmm. xlpe cable by digging 0.75 mtr. deep trench, putting layer of sand in the bottom, ramming it, laying of cable over it rmt and covering the cable from sides and top by laying bricks, finally covering the same by earth and levelling of the same, all the materials, except cable, will be pvovided by the contractor., fixing and termination of outdoor/ indoor heat shrinkable cable boxes of size 3 x300/3x185/3x120 sqmm. xlpe cable. boxes will be supplied by the contractor, sundries ( as per site requirement/emergency work), safe dismantling of 11 kv o/g pannel & received back to store, laying of weasel conductor with the help of aluminium roller by hanging three nos. on each support in a manner taking sufficient care to ensure safety of weasel conductor against rubbing on ground, precaution for safety of crops is also to be taken. the work includes jointing of conductor by providing jointing sleaves, stringing of conductor upto correct sag and binding of conductor with insulators on each support. all material shall be provided by contractor such as join
Tender For (1) replacement of existing steel girder bridge with psc slab 2x12.2m) (bridge no. 59 km 329/13-14 (up & dn) between chhapra kacheri-bhatni section, bridge no. 19 (sl) km 362/05-06 between kaptanganj-gorakhpur cantt section. (2) restoration work of cracked pier cap & seismic retainer of bridge no. 16 in gorakhpur cantt(ex)-valmikinagar (ex) (3) provision of ballast retainer & modification of psc slab ballast retainer, bridge tablet of minor bridge in gorakhpur cantt - bhatni section (17 nos) (4) 3d scanning of river bed of bridge no. 50 of span 14x61m in paniahwa-valmiknagar section (5) under water inspection with the help of robotic machine on bridge no. 119 of span 7x24.40m+1x12.20m between bhatpar rani-bhatni section.
Tender For , pila/kankar/jhajhra , , mortar/mud mixture , , lime from bud kiln for lime masonry work , , cement , , ppc , , white cement , , fine aggregate , , sand/gravel , , gravel local , , rakhi (fly ash) , , surkhi , , stone dust (in masonry) , , ballast stone/brick (for other than road work) , , 40mm measuring stone (hand-ground grit) (cut pieces 1/11) , , 40mm grit stone (crushed) (boyd's cars 1/11) , , 20mm grit stone (broken with a brusher) , , 12/10/6mm stone brittle (crushed) , , brickballast , , material for road work (including 5 km lead) , , 63-40 mm crusher broken stone crushed (cut boids 1/11) , , 63-40 mm hand-broken stone aggregate (cut bollards 1/11) , , 90-45 mm hand-broken stone aggregate (cut balls 1/11) , , query ranisha (cut boids 1/6) , , gravel (cut into 1/6" pieces) , , conker (cut voids 1/6) , , binding material (pi 4-6) (cut the blanks 1/6") , , brick (22.5 x 11 x 7.50 cm) , , first class , , ii class , , soling / kharanja / masonry stone , , chinnai berada (rr) , , vinai rada (cr) , , kharanja soling (for floor work up to 15cm height) , , kharanja soling (23cm height for road/kharanja work) , , jodhpuri type stone slabs/arches/slabs (length 2-3', width 10-12", thickness 2.5-3.5") , car jeep (flaky material)(3-4" thick & length and width 1-2") , , ऑटोर (dpc, sill, coping, lintel, tand, almirha etc) , , up to 25mm thickness , , up to 25-40mm thickness , , up to 40-50mm thickness , , up to 50-75mm thickness , , up to 75-100mm thickness , , up to 100-150mm thickness , , flooring / patti patan katla stone , , purse bottoms upto 35mm thick, min. 3 sqft or more area , , kavala 60-75mm painting for patti patan, min. 3 sqft or more area , , unpolished rough kota stone , , for more than 900 years , , 901 to 2300 sq cm , , more than 2300 sq cm , , polished kota stone (one side polished) , , up to 1900 sq cm , , 901 to 2300 years seri uk , , more than 2300 years ago , , marwal stone (makrana adanga 20mm thick) , , from 901 to 2300 square meters , , up to 900 sq. , , 5 more than 2300 sq cm , , marble poison , , marble paver , , marvel stone (rajgar ii quality/est. 20mm thick) , , 1 , , 901 to 2300 sq cm , , up to 2,900 sq. , , 3 more than 2300 berg seni , , stone frame , , single passham ghin 100 x 75 mm. , , eval paitam size 125 x 75 mm, , , stone slabs , up to 1.5 m length, minimum 40mm thick , 1.5 m to 2.40 m length, minimum 50mm thick , , 2.4 m to 3.0 m length, minimum 65mm thick , , 4 above 3.0 m length, minimum 75mm thick , , precast tiles/blocks , , 1 glazed size-30x45 cm , , 2 mosaic size-40mm thick , , 3 vitrified size-60x60 cm , interlock tiles/brick/block for road work , cement interlocking block m-30grade, 60mm thick , , 2 cement interlocking block m-30grade, 80mm thick , cement interlocking block m-30grade, 100mm thick , , single insulated copper conductor single core cable isi marked , , 1.50 sq km , , 2.50 sq mm , , 0.50 years mr. , , 1.00 sq mm , , 4.00 class v.shri , , mm at 6.00 , , local wood and fittings (doors, windows and panes) , , fire , , babut , , factory visit (30 mm bore, bore single pall) , , structural steel , , lox (for yer steel fe 415/500 racement) , , biding vapor 18 table , , iron piers , , konia lohachokor dharivapi/angle aart , , cutter iron wire (size 12 guage wire and 12 guage strad/12 guage wire and 14 guage strad/14 guage , , forged , , iron species (24 bases, 14 pegs) , , cement concrete sky and earth 40 inches thick , , 3mm fat mahas , , color paint , , prize belly , , झिपर (water bound) , , for lime-plastering (aaram/kati) , , prima (for iron/skadi) , , petroleum products , , bibat hsd , , cherished emergency , , bitumen shalila bhoi (25 mm thick) , , plain sheet (len chaha) , , g. i. sadar 22 dev (0.80 mm) , , bi four 24 sharp (0.63 mm) , , ms seat 22 table (0.80 mm) , , nl sheet 24 (0.63mm) , , corrugated mountain , , gi sheet r.b. thick , , aui sheet 22 table (0.80 μ.μ.) , , asbestos cement sheet 6mm(2.5/2.75x1m) , , other posts , pv meter sheet 1 mm thick (coloured/paw
Tender For 1)improvement of arch bridges by extending barrel length and construction of retaining wall, wing wall and ballast retainer on bridge no 561/2 dn(span 3 x 5.60m), 577/1 dn(span 2 x 6.10m) , 581/1 dn(span 2 x 6.10m) and 587/2 up&dn(span 5 x 8.10m) in dud-wd section of solapur division.( re-invitation)2) rebuilding of 04 orn-3 bridges ( 536/1a, 589/2, 589/3dn sur-wd section & 427/3 kwv-mrj section) in solapur division.( re-invitation)