Web Analytics Made Easy - StatCounter

Brick Drain Tenders

Get complete information related to latest Brick Drain Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Brick Drain Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Brick Drain Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45740855 Due date: 10 Jul, 202610 Jul, 2026 17.12 Lacs
Tender For construction of cc road and brick drain in village-karol bangar, yea. wc-06

Central Government/Public Sector

CTN :45726572 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair to joinery, flooring, false ceiling and certain miscellaneous b/r works, periodical services, petty repair works, cleaning and maint of sewage line, manholes, and repairs, cleaning and maint of drainage at hq ids under ge new delhi

Central Government/Public Sector

CTN :45723465 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For construction of kitchen shed height increse of boundary wall brick drain and miscellaneous civil work at 12 high school beltu

State Government

CTN :45710733 Due date: 20 Jul, 202620 Jul, 2026 48.62 Crore
Tender For construction of precast and rcc box type drain in place of old brick drain 1. from dabri roundabout to triveni park, pankha road (id-1155), 2. from pankha road to lajwanti satguru ram singh marg (id- 1226), 3. pankha road to janak setu pt. vishnu du

State Government

CTN :45710756 Due date: 20 Jul, 202620 Jul, 2026 45.64 Crore
Tender For construction of precast and rcc box type drain in place of old brick drain 1. from dabri flyover to mangalpuri flyover, palam dabri road (id- 1221), 2. dda office to flood drain, nasirpur road (id- 1223) under sd-1, swr-2, new delhi.

Central Government/Public Sector

CTN :45558318 Due date: 06 Jul, 202606 Jul, 2026 15.00 Lacs
Tender For corrigendum : repair and cleaning of sewage line, manhole, septic tanks and drainage at sector b harni area under ge (a) baroda.

CTN :45438320 Due date: 06 Jul, 202606 Jul, 2026 45.00 Lacs
Tender For corrigendum : supply of providing and laying of painting works , patch works , waterproofing works , dismantling false ceiling , dismantling bison board , dismantling woden partistion , window closing , dismantling existing washbasin , cleaning , room 3 , providing toilets , toilet renovation works , roofing and false celing works , room 9 , floor patch works , dismantling of toilets , dismantling damaged windows , room 14 15 , dismantling existing doors , repairs to existing ventilator windows , dismantling existing wall and floor tiles , structural repair and opening modification works , dismantling brick structure and floor repair , dismantling and vegetation removal , dismantling existing broken and damaged glass panes , cpvc water supply line , site clearance and general demolition works , anti termite treatment , rodent and pest control treatment , overhead water tank cleaning repair and disinfection , storm water drain and surface drainage , signage and room identification , comprehensive checking of 1 nos 250 kva outdoor type substations including inspection , aluminium paint , servicing of existing 11 kv 400 amps 3 pole gang operated type air break ab switch , supplying and replacing damaged or worn out copper metal , supplying and replacing damaged or defective 11 kv post top insulators , supplying and replacing damaged or defective 11 kv pin type insulators , servicing of earth pits , supply installation testing and commissioning lbs , xlpe insulated aluminium conductor armoured ht cable , providing indoor or outdoor type heat shrinkable , supplying and laying of 3.5 core x 240 sq.mm 1.1 kv grade aluminium conductor xlpe insulated , supplying and making end termination for 3.5 core x 240 sq.mm 1.1 kv grade , joint for existing single run lt power cable of size 3.5 core x 240 sq.mm , comprehensive servicing and preventive maintenance of existing ht transformer , supply, fixing, installation, testing and commissioning of lightning arrester , providing and fixing cable identification tags , supply, installation, testing and commissioning sitc main mv panel , supply, installation, testing and commissioning sitc cubicle pdb panel , supply, installation, testing and commissioning sitc feeder pillar box , providing and installation of maintenance free earthing station , supplying and laying of 3.5 core x 120 sq.mm 1.1 kv grade aluminium conductor xlpe insulated , providing laying and fixing of overhead perforated or slotted ms cable tray , supply installation testing and commissioning 7 segment distribution board , providing fabricating supplying, installing testing and commissioning of electrical socket box

Central Government/Public Sector

CTN :45365796 Due date: 04 Jul, 202604 Jul, 2026 11.50 Lacs
Tender For corrigendum : repair resurfacing of certain roads and connected items at bd bari mil stn - m&l preparing black top surfaces by brushing with wire brushes for removing caked mud etc. sweeping with wire brush/brooms and finally fanning the cleaned surface with gunny bags or by mechanical blower to remove all loose dirt etc to black top surfaces, and applying evenly a priming/tack (viscosity grade paving bitumen of grade vg-10) @ 5 kg per 10 sqm to road surface bituminous asphaltic semi dense concrete consolidated thickness 30 mm with stone chippings graded aggregate with 5.5% of binder content by weight of total mix, (viscosity grade paving bitumen of grade vg-30) and 4% stone dust conforming to required specification for filler as per irc-95, 1987 (filler) by weight of mix, prepared in hot mix plant, rolled and compacted to required camber and gradient to uniform smooth surfaces by mechanical paver and rolled with 8 to 10 tone power roller completed all as specified and as directed., m&l for repair to potholes, any depth ,not exceeding 1 sqm each including sweeping free from dust and mud or water, scoring sunken surfaces in roads, path etc, cutting around edges to at least 25mm in depth, making good by filling in screened and graded road metal, watering and well ramming, applying tack coat with (viscosity grade paving bitumen of grade vg-10) @ 10.0 kg per 10 sqm of surface putting in & including premixed bituminous macadam, well rammed and sealed with binder 9.80 kg/sqm, blinded with 0.09 cum of stone chippings, 6.3mm size and again well rammed, rolled and compacted to required camber and gradient to uniform smooth surfaces by mechanical paver and using with 8 to 12 tonne power roller (including supply of premixed macadam, binder and chippings),completed all as specified and as directed., premix bituminous macadam laid / rolled and compacted using 8 to 12 tonne power roller to required gradient and camber, with broken stone graded aggregate with 4% of paving bitumen binder of viscosity grade vg-30 grade by weight of toal mix (consolidated thickness 75mm or less) completed all as specified and as directed., m&l providing and laying at or near ground level factory made kerb stone of m-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required completed all as specified and as directed., m&l for marking lines 2.5 mm thick, dashes arrows etc of any description n. exc 10cm width/girth on road surface using hot applied thermo plastic road marking paint of approved colour confirming to bs-3262-1989 with special applicator machine all as per manufacturere instruction completed all as specified and as directed., supply and fix solar cat eye (green/red) aluminum alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency mono rystafie solar panel 2.4v/ 0.3 watt one ni-ed rechargeable battery (1.2v/ 1600ma) consisting of super bright led with 10,000 to 18,000 mcd completed as per manufactures instructions etc completed all as specified and as directed., supply and fixing metal tubular dealineator made out of abs round body fitted with 2 nos 65 mm dia highly reflective reflectors made out of and mounted on 45/50 mm dia mild steel pipe of 600 mm height duly powder coated and thermo plastic elastomer 3 bands of green, red and yellow reflector radium tape of 25 mm wide strips with anti theft steel net for reflector protection including embedding in pcc 1:2:4 (150x150x300mm) type b1 complete all as specified and directed, s&f manufacturing, supplying and fixing retro reflective mandatory/ regulatory sign boards of 900 mm diametre with support length of 3750 mm and made up of 2 mm thick aluminium sheet, face to be fu

Central Government/Public Sector

CTN :45671381 Due date: 15 Jul, 202615 Jul, 2026 50.00 Lacs
Tender For repair/maintenance and cleaning of sewage line, manholes, area drainage and other allied b/r works of area-v under ge (west) colaba, mumbai

Central Government/Public Sector

CTN :45697387 Due date: 16 Jul, 202616 Jul, 2026 48.00 Lacs
Tender For repair/replacement of sewage lines manholes septic tank brick drain and certain miscellaneous b/r works at af stn narela under ge (af) gurgaon
 Loading, Please wait...

Connect us via What's Up