Get complete information related to latest Bridge Quartz Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bridge Quartz Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bridge Quartz Tenders.
Tender For bid to ras corrigendum : supply of civil lab equipment d d - impact testing machine , crushing value testing machine , los angeles abrasion testing machine , flakiness index test gauges , elongation index test gauges , aggregate water absorption test set up , pycnometer as per requirement , is sieves for coarse aggregate gi sieves dia 300 mm , is sieves for fine aggregate brass sieves dia 200 mm , automatic sieve shaker 18 inch , bitumen extractor machine , vicat apparatus with deskpot , le-chatlier flasks , le-chatlier moulds , burette as per requirement , measuring cylinders , trowel small , trowel big , trays , sampling scoop , steel buckets as per requirement , cement cube moulds , automatic manual mortar mixer as per requirement , vibrating machine as per requirement , curing tank with controlled temperature , atterberg limits set-up liquid limit , atterberg limits set-up plastic limit , shrinkage limit apparatus with mercury , hydrometer analysis set-up range , free swell index apparatus , proctor testing equipment , core cutter test set up for in-situ density min. 6 mould with 01 hammer , sand replacement test set up for in-situ density , moisture container for omc by conventional method , hot air oven digital , physical balance electronic , rapid moisture meter , thermometer for measurement of room temperature , thermometer for measurement of temperature of bitumen, concrete , digital compression testing machine 2000 kn capacity semi automatic , digital compression testing machine 500 kn capacity , measuring tape 3m , measuring tape 10m , measuring tape 30m , measuring tape 50m , concrete cube moulds , concrete mixer 0.5 cum capacity electrically operated , concrete workability test by compaction factor test , ph meter , paint thickness meter elcometer ultrasonic digital , dial callipers , vernier callipers , digital micrometre , outside micrometres , depth gauge , density pot , density basket , slump test apparatus , electric platform balance 150 kg , electric pan balance 10 kg 1gm , precision balance 600 gm 0.1 gm , measuring flask , upv ultrasonic pulse velocity tester , rebound hammer , core falltering machine , flexural test appratus for beam , core cutting setup for conceret , rebar detector to locate reinforcement before core cutting
Tender For purchase of equipments - purchase of equipment, bench top glass insitu airlift photo bioreactor1. vessel capacity: 3 liter borosilicate glass (working volume: two to three liters maximum), vessel hxd ratio 4:1 (400x100mm)2. head plate & bottom plate moc: ss 316l3. ports in top plate: ph sensor; dissolved oxygen (do) sensor; pressure sensor; air in and draft tube; air out; acid/base; sampling; and addition port.4. mixing method: ring sparger to create airlift circulation inside the reactor for uniform mixing and better aeration.5. holders for sensor /adapter / blind stoppers in head plate: ph sensor holder; media double inlet for acid/base dosing; air sparger - ring type for airlift application without stirring, air out with exhaust filter and open/close valve; pressure sensor holder; sampling pipe; blind stopper for un used port; unique suitable ss puncturing needles for sampling, air in, air out, inoculum, feed addition.6. ports in bottom plate with stand: port for temperature sensor; heating finger u-tube heat exchanger; drain.7. holders for sensor / adapter / blind stoppers in bottom plate: holder for temperature sensor, heating finger, u-tube heat exchanger.8. sensors: temperature, gel filled sterilizable ph sensor, & pressure sensor.9. controls and display: modular independent system of ph, temperature, pressure with touch screen graphical display & control; two set point control of ph with three-point buffer auto calibration; aeration by flow meter 0-5lpm with air pump; sterilization controls up to 121 without steam generator along with pressure safety mechanism by independent pressure sensor and digital display & control; automatic digital pressure safety and over temperature safety cutoff and alarm; upgradable control system for future prospective as cstr reactor & dissolved oxygen (do).10. measurement and control range: ph: 2-14; process temperature: 20 to 60 ; sterilization temperature: up to 121 ; and pressure up to 15 psi.11. fixed speed peristaltic pump: for acid/base dosing with teflon non spring head. (2 nos)12. cooling system: chiller cum circulator. chiller temperature range 4 to 40 , bath capacity 5l to cool down the reactor after sterilization and to work process temperature below ambient condition.13. illumination system: two illumination assembly with variable intensity control (1000-3000 lux) around the reactor with independent control switch for photobioreactor, or other application and easy detachable if not in use. 14. essential accessories : silicon tubing for acid/base addition (10m); air in and sampling (10m); water circulation (5m); air vent filters 0.2 micron sterilizable (6nos); and silicon septum (25nos)15. starter kit: spare silicon-o-rings for head plate, bottom plate (1no each), all other ports (5nos each), alen key.16. warranty: one year17. support (must): unconditional onsite technical support shall be provided as and when needed. the supplier must provide complete installation and hands-on demonstration of the equipment at the user site upon delivery.18. the vendor should have a registered presence in india with an authorized local service provider in tamil nadu.
Tender For purchase of equipments - purchase of equipment:chromatographic workstation with capillary injector, packed injector, and auto-sampler should be quoted. chromatography workstation instruments should be built with self-diagnostic features and active-time management tools for better productivity, general features of chromatography workstation: column oven can accommodate two columns with maximum temperature range up to 400 c with set point resolution of 0.1 c. it should support 20 ramps & maximum temperature ramp rates of 100 c /min. cool down of oven from 400 c to 50 c in less than 5 min. fully automated with electronic pneumatic control afc / ppc / epc (digital control) for injector gas afc/epc/ppc should provide optimum performance with all types of capillary columns. system should have the capability to install a minimum of three injection and four detector ports. capable of detecting h and o across 0.01% 100% ranges (i.e., both trace in a matrix and bulk near-pure streams) column oven: operational temperature range: ambient +10 to 400 c overheat protection: programmable up to 420 c injector port: split/spitless injector 1 no packed injector 1 no, maximum temperature: 400 c, pressure setting range 0 100 psi with control setpoint of 0.01psi for specified pressure range., carrier gas flow control should have constant flow, constant pressure modes and constant linear velocity. auto injector: automatic sample injector up to 15 vials 2 ml vial with crimp set 100 nos, detector: flame ionisation detector (fid) 1 no, minimum detectable quantity: 3 pgc/s or more liner dynamic range: 1 107, maximum acquisition rate: 4 ms (250hz), thermal conductivity detector, sensitivity: >40000 mv maximum acquisition rate: 4 ms, maximum operating temp: 400 cgas cylinders & fittings, gas sampling: zero air, h2, n2 and helium gas cylinder with 2-stage regulators, each 1 no. four-stage gas purification panel and gas tubing. quote a suitable gas sample injector apparatus for the analysis of co2 gas, gas standards and a suitable packed column quote a 6-port gas sampling valve suitable for both manual (through syringe) and auto injection (online) quote sample line, sample loop, heated lines, filters, safety hydrogen purging, and flow control of gas. calibration gasses: suitable gas standards such as ar, he, h2, o2, co and ch4 should be providedpc and ups: pc i5 (or higher), 8gb ram, 1tb hdd, 22-inch led monitor (or higher), ssd: 512 gb, windows 10 os (or higher), wired keyboard and mouse. laser printer b/w, online ups sine wave capacity of 5 kva with battery power backup of 1 hour should be provided by the supplier general terms and conditions:warranty: 3 years manufacturer s warranty certificate. vendor should be an authorised provider of sophisticated high-precision chromatograph workstation systems for the past 15 years or more with: a proven track record in multiple countries and national institutes standard quality certifications such (iso 9001) 5+ past installations of similar systems in india. compliance statement should be enclosed with the quotation. the installation should be done at free of cost. hands-on training for 1 day for two trainees (faculty and scholars) must be provided on operation, maintenance and troubleshooting to two to two-three persons at the site of installation. if required, hands-on training must also be given to our faculty/scholars at a later stage, without any financial commitment to university. the technical details of the quoted instrument must be available on the official website of the principal supplier. the vendor should provide the list of end-users (recent) with contact details. the vendor must submit the latest reference letters from their previous users. trained service engineers in india (with suitable certificates) for the quoted model must be readily available to resolve the technical problems. a list of recent scientific publications in reputed journals from the user institutions where the quoted mode
Tender For a) scope of work covers supply, installation and commissioning of total 12 nos.of 3d radar level transmitters for the coal level measurement in raw coal bunkers of rtps-unit-5&6 with required pcs, electronic modules, splitters, modems, junction boxes, mounting kit, enclosures, interconnecting cables, software and all other accessories required to make the system complete and fully functional, shall be provided for continuous level measurement and monitoring of level of each coal bunker and also to ensure satisfactory performance of the system commissioned at rtps site which shall be on the basis of single point responsibility, completely covering the activities and services in respect of all the equipment works specified and covered under the specifications. the work involves i) installation and commissioning of 12 nos. 3d radar level type level transmitters with suitable mounting accessories, display indicators, isolators, annunciator, smps, terminals, panel internal wiring, led bulbs, door switch etc. at the bunker level ii)commissioning of rs 485 communication /other cables from bunker level transmitters to the desktop pc at u-5&6 control rooms.iii)commissioning of desktop pcs for 3d multi vision for monitoring of all the 12 bunkers level at u-5&6 control room respectively and also both units bunker levels at pc being installed at chp control room. iv)loading of all the required licenced software to the desktop pc for 3d radar level transmitter and cable routing, glanding, mounting of cable tray, termination and ferruling is in the contractors scope.cable trays will be provided by m/s.kpcl.b)all fabrication works required for installation and commissioning of instruments with jbs,protective cover/canopies and allied works are in contractor/agency scope itself.c) all civil works like drilling/cutting rcc floors,grouting,refilling floors,conduiting under ground cables cable tray mounting, masonary works are in contractor/agency scope itself.d)storage of materials while executing works is single point responsibility of contractor/agency scope itself. e)software details-1. the page containing all bunker level data shall be in full page which must be visible from at least a distance of 6-8mtr .(font size should be more) and shall have a historical trend storage for minimum 45days & real time trend with not less than15min sampling time. f) at chp control room, the existing kpcl pc shall be enabled with bunker level software & shall be communicated through existing lan and as a redundancy the seperate optical fiber cable communication with media convertor has to be provided.the lan cables has to be protected with cable conduit g)materials supply shall be completed in all respect within the stipulated period as per the contract. materials shall be delivered to rtps site through ee(stores)o&m. unloading of materials at rtps site location and shifting of the same to work location is under the contractor/agency scope only. h)handling, shifting, unpacking and erection and commissioning of the entire system shall be under the scope of bidder itself. i)all required consumables, hardware and licenced software, accessories and any other materials which are not included in the scope and required for successful installation and commissioning of the 3d radar level transmitters for the coal level measurement in raw coal bunkers of rtps-unit-5&6 are under the contractor/agency itself. j)all the materials required for the installation and commissioning of 3d radar level transmitters for the coal level measurement in raw coal bunkers of rtps-unit- 5&6 shall be made as detailed under the technical specifications. k)interfacing of all the bunker level transmitters outputs to the desktop pcs at u-5&6 control rooms through rs - 485 communication protocol.(the required 1 pair x 1 sq.mm shielded armoured cables as per requirements shall be supplied approx-500 meters or if more). for more details of scope of work refe