Tender For procurement of furniture for workstation of prefab staff room in pmda office sector 3, panchkula - providing, supplying and placing of workstation chair with cantilever flex system, three position back tilt limiter. seat/back assembly: the cushioned seat assembly consists of seat base moulded in glass-filled poly-amide, moulded polyurethane foam and upholstered with high stretch knitted polyester fabric. the cushioned back assembly consists of back inner moulded in polypropylene in-situ moulded with polyurethane foam and upholstered with high stretch knitted polyester fabric. back size : 45.5 cm. (/w/) x 53.0 cm. (h) seat size : 48.5 cm. (w) x 49.0 cm. (d) high resilience (hr) polyurethane foam: the hr polyurethane foam used in seat and back cushion is moulded in density min 48 kg/m3, and hardness load 15 2 kgf as per is:7888 for 25% compression. tilt mechanism, spines and spine connector: the seat and back are firmly connected to the base frame and are cantilevered in such a way that it gives a multi-dimensional movement possibility just with a simple lean on the sides or back, without need for complex manual adjustments. the cantilevered seat offers impact cushioning while sitting and synchronises with the back movement during posture changes. the `s` shaped spines moulded in high strength glass-filled poly-amide and the spine connector moulded in glass-filled poly-amide form the back-spine structure involved in multi-dimensional recline motion. the variable tilt angle recline motion can be adjusted with 3 position tilt limit feature which should be inbuilt in seat base and the tension (return force) should be user weight dependent. adjustable armrests: the assembly consists of armrest housing sliding over the armrest structure, both moulded in glass-filled poly-amide: the height adjustment feature should be button operated having adjustment of 6.6 0.5cm. the armrest top should be made up of integral skin pu moulded over plastic inner moulded in glass-filled poly-amide. pneumatic height adjustment: the seating height can be adjusted with a pneumatic gas-lift having an adjustment stroke of 9.2 0.3 cm . pedestal assembly: the pedestal should be injection moulded in glass-filled poly-amide and fitted with 5 nos. twin wheel castors. the pedestal should be 66.0 0.5 cm. pitch centre diameter and 76.0 1.0 cm. with castors . twin wheel castors :5 nos. twin wheel castos are injection moulded in poly-amide having 5.0 0.1 cm wheel diamter assembled to the pedestal. overall dimensions of chair seat height - min 44.5 to max 53.8 cm. height - min 99.5 to max 108.8 cm. width and depth of chair as measured from pedestal - width-76.0 cm and depth-76.0 cm. the product should be greenguard, griha and iaq certified, providing, supplying and placing of workstation chair with cantilever flex system, three position back tilt limiter. seat/back assembly: the cushioned seat assembly consists of seat base moulded in glass-filled poly-amide, moulded polyurethane foam and upholstered with high stretch knitted polyester fabric. the cushioned back assembly consists of back inner moulded in polypropylene in-situ moulded with polyurethane foam and upholstered with high stretch knitted polyester fabric. back size : 45.5 cm. (/w/) x 53.0 cm. (h) seat size : 48.5 cm. (w) x 49.0 cm. (d) high resilience (hr) polyurethane foam: the hr polyurethane foam used in seat and back cushion is moulded in density min 48 kg/m3, and hardness load 15 2 kgf as per is:7888 for 25% compression. tilt mechanism, spines and spine connector: the seat and back are firmly connected to the base frame and are cantilevered in such a way that it gives a multi-dimensional movement possibility just with a simple lean on the sides or back, without need for complex manual adjustments. the cantilevered seat offers impact cushioning while sitting and synchronises with the back movement during posture changes. the `s` shaped spines moulded in high strength glass-filled poly-amide and the spine
Tender For tender for the supply of various equipments - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles, karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard, refrigerated centrifuge (bench top), bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples., gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25m (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25m),, "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 l recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:, matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water., ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubings, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 l, 20 l, 50 l, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each of, c8 = 250 4.6 5m c18 = 250 4.6 5m, cyano = 250 4.6 5m. amino = 250 4.6 5m, phenyl = 250 4.6 5m. silica = 250 4.6 5m., all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., ft-ir with atr & liquid cell, " hydraulic press with kbr die and pellet holder, suitable mortar pestle (dia 5-6 cm), suitable portable de humidifier to maintain 30- 60% rh, temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab., reference nist standard polystyrene film (0.3 mm) over the range of 3800 cm-1 to 650 cm-1., abbes refractometer,
Tender For supply of calcium based granular disinfectant for water treatment, more stable than chlorine gas and stronger than bleaching powder and sodium hypochlorite , connection of chlorine 60 to 70 percent suitable of one year with minimum loss of chlorine. the chlorination chemical must contain appropriate quality of dispersant/corrosion inhibitor to prevent scaling in distribution system .strength in terms of quality of chlorination comical required to obtain free chlorine of 1 ppm per 1 lakh liters of water to achieve 1 ppm avcl at injection paint site and raw water quality variations may apply additionally packing in non returnable plasticdrum. make/brand- altoch gp or similar. ]
Tender For corrigendum : tender for the supply of various equipments required for upgradation of district food laborartory, karnal - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles", karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard", refrigerated centrifuge (bench top),, bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples.", gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25µm (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25µm),", "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 µl recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water.", ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubing’s, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 µl, 20 µl, 50 µl, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each ofc8 = 250 × 4.6 × 5μm c18 = 250 × 4.6 × 5μmcyano = 250 × 4.6 ×5μm. amino = 250 × 4.6 × 5μmphenyl = 250 × 4.6 ×5μm. silica = 250 × 4.6 × 5μm.all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate.", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate.", ft-ir with atr & liquid cell, "• hydraulic press with kbr die and pellet holder• suitable mortar pestle (dia 5-6 cm)• suitable portable de humidifier to maintain 30- 60% rh• temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab.• ref