Get complete information related to latest Bucking System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bucking System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bucking System Tenders.
Tender For tender for supply of mvk output vd ce 5 poc pcba pha29040 , limit switch 1 nc 1 no xckn2110p20 , ptc heater , 150 w , 110-250 v ext00925 , rh50e-4dk.6k.1r mfr23210 , 500mm fan inlet nozzle mfr23916 , mvk 145-65a without bypass pha18195 , eht-c , 110-250 v ac , enclosure hygrotherm ext00926 , current hall ct y2100023 , 150a or 5a 27 metsect5ma015 , ac or dc single phase 100...240v or 24v 4.5a 100w ablp1a24045 , signal converter rmcn22bd , 250v ac or dc 3a to 36a 2-line b84113h0000b060 qgh68656 , miniature plug-in relay - zelio rxm 2 c or o 24 v dc 12 a with led rxm2ab2bd , zelio relay protection diode module rxm040w , zelio relay socket rxze2m114 , three-phase control relay 183 528vac , 2 c or o rm22tg20 , contactor tesys lc1d 3p ac 3 440v 9 a , coil 24 v dc lc1d09bd , tesys gv2me 3p 1 1. 6 a gv2me06 , 40 io transistor pnp ethernet tm241ce40t , 10w touch advanced display wxga hmidt551 , open box for universal panel hmig5u2 , converter i to i , 2ch , i or p 4-20ma , o or p-1 and 2 4-20ma , supply 110v or 2 30vac , isol 2000vdc , din rail mo unting , dim 55mm w x 75mm h x 110mm d , accuracy 0.1 percent of fs , converter i to i 1 ch i or p 0 to 1 a ac o or p 4 to 20ma supply 90-270vac or 100-250vdc , converter i to i 1ch i or p 4 20ma o or p 4 20ma supply 90 270 vac or 1 00 250vdc isol 2000vdc din rai l ounting dim 55mm w x 75 mm h x 110mm d , accuracy 0.1 percentage of fs , fan axial model 2e -250b , with flat grill , 1ft cbale length , 2p , 230vac supply , 50hz , 115 w , 0.55 a , 3uf capacitor , rpm-2400 , air flow 1730m 3 or hr , cfm-1018 , noise level 65db , 37k 57a 450vac 10 percent 3 phase , semiconductor fuse 100a , 690v ac , part no. 170m1567d , size 000 , square body , blade style , dual indication , high speed fuses , ct metering 100-120a or 1a , 7.5va , accuracy class 1 , window size 35x20 , overall size 95x95x95 , t erm. arrg. no. 2 , ct metering 100-120a or 5a , 7.5va , accuracy class 1 , window size 35x20 , overall size 95x95x95 , t erm. arrg. no. 2 , digital operator utp cable of 3m with rj45 connector for c ommunication between drive and operator
Tender For supply of spares for 02 nos float and boost chargers for 220 vdc and 48vdc battery bank at power house c c - 16a ammeter selector switch for main input current selection , 16a voltmeter selector switch for main input voltage selection , 10a tp ac 2 way without off auto or manual mode selection for float and boost chargers , 16a sp dc 2 way without off switch for float rectifier or load bus and boost rectifier or battery voltage selector switch , 16a sp ac 2 way without off auto c or o mode or manual boost mode selection for charger , 10a tp dc 2 way without off for boost charging of battery set 1 or 2 selection , 225a dc coil operated emergency contactor coil 220v dc auxi 1no , 185a dc coil operated contactor for boost charging battery set 1 coil 220v dc auxi 2 nc , 63a dp dc on or off switch for load isolation , 40a dc coil operated emergency contactor coil 48v dc auxi 1no , 65a dc coil operated contactor for boost charging battery set 1 coil 48v dc auxi 1 nc , filter capacitor for ripple suppression for float and boost chargers rating 100 v 2200 uf , dc to dc convertor 48v dc to 24 v dc 5 amps , 4 channel relay boards for contact multiplication of card mounted protection relays , electronic card module for avr and current limit for float charger auto and manual mode , electronic card module for avr and current limit for boost charger auto and manual mode , electronic card module for float and boost rectifier fuse fail and filter fuse fail , protection module for various fault detection and annunciation , blocking diode for float and boost charger rating 70a i avg piv 800 for fcb mode on k3 heat sink , 80 percent blocking diode stud type rating 70a i avg piv 800 on k3 heat sink , latching resistor for rectifier. 250 ohms 50 watts for float and boost chargers , 10k 1w potentiometer for auto or manual voltage adjust in float charger , 10k 1w potentiometer for auto or manual current adjust in boost charger , 2ph control transformer for power supply of avr cards prim 415 v sec 16 0 16 v ac 400ma , 3ph control transformer for synchronising of avr cards. pri 415 v sec 16 0 16 50ma , 3ph control transformer for ac u or v pri 415 v 3 phase sec 0 16 vac 1 phase 250 ma , 2 0fi control transformer for fan control supply prim 415 v 2 phase sec 190v ac 50va , scr stud type 70a with heatsink loose module only , diode free wheeling stud type 70a with heatsink loose module only , digital ac ammeter 48 x 96 sq mm class 1 ct ratio 25 or 1a auxiliary voltage 24v dc , digital ac voltmeter 48 x 96 sq. mm class 1 range 0 500v ac auxiliary voltage 24v dc , digital dc ammeter for float boost chargers and 80percentage cell tap 48 x 96 sq mm class 1 75mv dc with shunt auxiliary voltage 24v dc , digital dc voltmeter 48 x 96 sqmm class 1 range 75mv dc auxiliary voltage 24v dc , digital dc charge or discharge ammeter for battery 48 x 96 sq mm class 1 range 75mv with shunt auxi 24v dc , transportation charges for material
Tender For supply of procurement of spares for cg make ht switchgears d d ? g? g -resin cast spout assembly part no cg8060 , spout fitting with connector part no cg8061 , front insulated connector r part no cg2421 , front insulated connector y part no cg2422 , front insulated connector b part no cg2423 , rear insulated connector r part no cg2821 , rear insulated connector y cg2822 , rear insulated connector b part no cg2823 , instrument control box part no cg2070 , vertical isolating vcb trolley part no cgv008 , earth leakage relay with cbct part no cg0172 , power converter 110v ac to 110v dc part no cg4949 , tripping coil 110v dc 220v dc part no cg28110 , mechanism for tripping coil part no cg28111 , master trip relay part no cg13vajh , 11kvby110v drawout type epoxy resin cast 3ph pt part no cg98n04 , digital protection relay part no cgp154 , epoxy resin cast ct part no cg88200 , side cable box part no cg2222 ) /bid number: gem/2025/b/6946820 * /dated: 03-12-2025 & & / bid document1 / 25
Tender For provisioning of electrical and mechanical eqpt against ber under ge 862 ews - supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 300 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type(m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 450 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fitting & accessories e.g marking plate, lifting lugs, ci rollers, earthing terminals, cable box including suitable platform as reqd on site complete all as as specified & directed., supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 100 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type (m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 150 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fi