Get complete information related to latest Buffer Coupler Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Buffer Coupler Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Buffer Coupler Tenders.
Tender For supply of coupler body with shank wear plate for upgraded high tensile centre buffercoupler for boxn hl wagons to rds sk62724 item no. 1 & 10 alt. no.30. spec:wd-70-bd-10 rev-03. as per drg.no. sk-62724, item no-1&10. specn: wd-70-bd-10 rev-1 [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For m. s. under frame electrical inspection junction box cover as per tlw drawing no. tlw/08/11. sample to be got approved before effecting bulk supply. [ warranty period: 12 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For repair replacement of internal wiring incl sub main wiring, mcb dbs, bldgs security lights and connected items in pocket 1 to 8 under ge roorkee - taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed., m&l for point wiring with 1.5 sqmm frls-h insulated, unsheathed, multistranded, 1100 volts grade copper conductor cable single core conforming to is:694 along with one run of 1.5 sqmm frls-h insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories / junction boxes / inspection covers etc of suitable size but not less than 20mm(od), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass gi screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., all as per item no 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch., all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one one light point controlled by two no. two way switch complete all as specified and directed, all as per item no. 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., m&l for sub main wiring along with earth wire with frls-h insulated copper conductor, single core cable drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(ph & n) + 1run x 4 sqmm(earth wire):- (note: three runs of copper cable and one run of pvc conduit shall be measured as one unit length), all as per item no 11 here-in-before but 2runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), all as per item no 11 here-in-before but 2runs x 10 sqmm(ph & n) + 1run x 10 sqmm(earth wire), all as per item no 11 here-in-before but 4runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), notes for item no. 2.00 to 14.00(i) quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) if any beam / column / rock wall is encountered while cutting chases, that particular portion may be provided with pvc casing & capping or surface conduit for drawing cables and surface pvc gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) no cutting shall be done on ceiling for laying pvc conduit for ceiling fan point wiring. surface conduit or pvc casing capping may be
Tender For supply of wedge assembly for balanced draft gear of sanrok make high tensile tightlock centre buffercoupler conforming to rdso specification rdso/2011/cg-03, rev.-01 and to sanrok drawing no. 1ed-1054 [ warranty period: 30 months after the date of delivery ] ]
Tender For submission of a rate schedule for machinery and equipment to prepare an estimate for installing rainwater harvesting systems in stormwater lines and low lying areas along main and internal roads within the municipal corporation limits. - item name, providing and constructing recharge pit of 2.0m deep and 1.0m dia of precast rcc rings with 6.5 dia. x 25m deep bore well at the floor of recharge pit including providing and supplying one complete ai-enabled single integrated modular smart groundwater recharge unit with recharge-volume measurement, real-time clog monitoring, recharge-water quality monitoring, soil quality / site suitability assessment, iot communication, ai dashboard and gis monitoring platform, suitable for urban rainwater and storm water groundwater recharge applications. the supplied unit shall be a single integrated smart recharge unit and shall not be a combination of disconnected or separately assembled devices. all field-level hardware, sensors, filtration arrangement, sedimentation section, recharge-volume measurement system, real-time clog monitoring system, recharge-water quality monitoring system, iot controller, communication module, qr/gis asset identification and data communication components shall be integrated within the supplied smart recharge unit and shall operate as one complete system. the ai dashboard, gis monitoring platform, cloud hosting, sim/data communication and software support shall be digitally integrated with the supplied unit for live monitoring, alerts, analytics and reporting. internal components shall not be treated as separate payable items. the main body / modular assembly of the unit shall be made primarily from hdpe/frp / upvc or equivalent corrosion free material and shall be suitable for long-term contact with rainwater / storm water, groundwater recharge applications and repeated cleaning. the unit shall be corrosion-resistant, water-resistant, durable and easy to maintain. the unit shall be modular, removable, reusable and serviceable. the design of the unit shall enable cleaning, sediment removal, filter inspection, filter-media replacement, sensor inspection and refitting without damaging the surrounding civil structure, chamber or recharge arrangement. the unit shall have a minimum external diameter of 750 mm and minimum overall height of 2000 mm with frp cover of suitable size having 40 mt capacity. the unit shall have sufficient internal space for filtration arrangement, sediment holding, recharge-volume measurement, real-time clog monitoring, water-quality monitoring, iot components, sensor housing, cleaning access and maintenance. the unit shall include multistage filtration, debris arrest arrangement, first-flush / bypass provision, sedimentation and silt-management section, recharge-volume measurement system, recharge-rate monitoring, real-time clog monitoring, recharge-water quality monitoring after filtration and before recharge, soil quality / site suitability assessment module, iot-based data communication, qr, gis asset identification, ai-enabled web dashboard, gis monitoring platform. the unit shall be capable of measuring, recording and reporting actual recharge volume, recharge-rate trend, sedimentation status, clogging condition, recharge-water quality parameters, soil / site suitability parameters, unit health, sensor health, battery status, communication status and maintenance status on a web-based dashboard. the item shall be treated as one complete integrated smart unit. internal components such as hdpe/ frp modular body, filtration arrangement, sedimentation section, measurement systems, sensors, iot controller, communication module, ai dashboard, gis platform, cloud hosting and sim/data support shall not be measured or paid separately. the unit shall have authentication from any govt. institute like c.o.e.p./cw&prs/gsda etc. the unit shall be supplied with five years warranty against manufacturing defects, material defects and functional failur
Tender For supply of inspection cover for tr motor type 4303dy of demu/dpc as per drg. mo. -jmp/sk-4/12. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of modified set of shims for aar 'h' type tight lock enter buffercoupler for lhb coaches as per rdso drawing no cg-15090, alt-nil. one set consists of 01 no. of size: 3mm, 5mm, 10mm, 15mm, 20mm each. material specification is: 2062-2011 amendment -1 e410 br. nabl certificate for material specification is required at the time of delivery of material. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of coupler body for high tensile transition centre buffercoupler for b.g. locomotive to rdso drg. no. sk.-62724 alt-28 or latest , item no.18 and as per spec. no. 56.bd.07 with amendment no.1 & 2 or latest. [ warranty period: 48 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]