Get complete information related to latest Bund Wall Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bund Wall Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bund Wall Tenders.
Tender For up-gradation works of kendriya vidyalaya, itbp, bhanu, distt. panchkula, haryana. sh : repairs of old damaged grit plaster, assembly stage flooring with kota stone and covering of assembly stage with sheet roofing, renovation of staff and student toilets, repairs of damaged boundary wall including painting of school building and boundary wall including electrical worksubwork/packages:repairs of old damaged grit plaster, assembly stage flooring with kota stone and covering of assembly stage with sheet roofing, renovation of staff and student toilets, repairs of damaged boundary wall including painting of school building and boundary wall including electrical work
Tender For corrigendum : provn of boundary wall pilars covering entire periphery of baisakhi mil station and provn of 150 mtr interlocking pathways tiles and retaining wall at adhoc transit camp at 18 sikh li under ge 859 ews
Tender For corrigendum : rectification of electrical safety defects - supply and installation of electrical danger notice boards conforming to is 2551 1982 and the indian electricity rules, 1956. each board shall be fabricated from mild steel plate not less than 1.6 mm thick, vitreous-enamelled in visible red finish, with lettering, figures, and skull-and-crossbones emblem in signal white. plate size 200 150 mm with rounded corners, suitable for 415 v medium-voltage installations, bearing bilingual wording (english and tamil) centrally spaced as per the standard. fixing holes of suitable diameter for rivets shall be provided at the corners. boards shall be permanently affixed in conspicuous positions on distribution boards and panels using corrosion-resistant rivets or equivalent fasteners. the rate shall be quoted per piece inclusive of supply of board, rivets, and complete affixing, inspection, testing, cleaning, recommissioning, and submission of the test report for the lightning protection system installed on a 30 metre-high ms wireless tower, including the removal and replacement of all associated fasteners on the downcomer gi plate, ensuring full compliance with applicable standards and operational safety requirements. , inspection and testing of earth electrodes; reconditioning and refilling of earth pits; removal of corrosion from contact plates; replacement of fasteners; cleaning of earth pit troughs; correction of wall separators for earth pits; painting with yellow colour; fixing of durable identification labels with red-coloured text in the respective troughs; provision of closure slabs; and submission of test reports along with photographic evidence. walls to be provided newly: 5- earth pits with existing walls: 22, refilling of silica gel in 11 kv/415 v step-down transformer breather, ensuring proper colour indication and complete replacement of exhausted, dehydrated, or saturated silica gel., insulation and safety covering of exposed live terminals in the 125 kva dg set and of the outer surface of the tneb ht meter box using pvc/acrylic insulation sheets of adequate thickness, rating, and appropriate size suitable for the respective voltage levels, ensuring full electrical insulation and compliance with safety standards. size; 30x20 inches-1 no. 12x24 inches-1 no.
Tender For supply of provision of lighting arrangement for the watch tower along with solar system at kushinagar airport : : - design and sitc of off grid solar system of 1 kwp capacity along with suitable capacity inverter and 2 nos. of 150 ah solar tubular battery along with necessary module mounting structure & civil works like foundation etc. as required at site for upssf watch tower in operational area of airport., supply of 4c x 6 sq. mm xlpe insulated & pvc sheathed, armored aluminium conductor cable of 1.1kv grade as per is 7098 (part i) 1988 with up to date amendments etc. complete as required., laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required.upto 35 sq. mm (clamped with 1mm thick saddle), laying of hdpe pipe upto size 50 mm complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required., laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/hume/metal pipe as required.upto 35 sq. mm, supplying and fixing of following way single pole and neutral, sheet steel, mcb distribution board 240 v, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 6 way, double door, supplying and fixing 6 amps to 32 amps rating, single pole, 240 volts, 10 ka, c curve, miniature circuit breaker suitable for inductive loads in the existing mcb db complete with connections, testing and commissioning etc. as required., supplying and fixing dp mcb 32 amps, double pole, rating, 240 volts, 10 ka, c curve, miniature circuit breaker in the existing mcb db complete with connections, testing and commissioning etc. as required., wiring for light point/fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit, with modulat switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper stranded conductor single core cable etc. as required.(group c), wiring for circuit/ sub-main wiring along with earth wire with 2x2.5 sq.mm+ 1x 2.5 sq.mm earth wire.sizes of frls pvc insulated copper conductor, single core stranded cable in surface/ recessed steel conduit as required., supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required., supply of 20 watt led batten surface mounted suitable for operation on 230 volt,50hz ac supply, complete etc as required., supply of 400 mm, 2100 rpm wall mounting swinging fan suitable for single phase 230 volt, 50 hz ac supply complete with motor, capacitor, mounting clamps etc. with all accessories as required complete., installation, testing and commissioning of pre-wired led fitting luminaries etc. of all types (surface/recessed) & street lights complete with all accessories. directly on ceiling/ wall , including connection with 1.5 sq.mm frls pvc insulated, stranded, copper conductor single core cable with flexible conduits and coupler and earthing etc. as required., installation of wall mount fan in the existing opening including making good the damage, connections, testing and commissioning etc. as required.upto 450mm sweep., supply of led street light of minimum lumen output of 3600 lumen made up of pressure die cast aluminum housing with membrane filter and have ip66 optical as well as electrical compartment with wide operating voltage range of 230+/- 10 percentage complete with all accessories as required., providing & fixing 32/40 mm dia b class gi
Tender For construction of drain cum concrete bund / wall from house of abdul aziz sheikh to land of gh hassan mir at chount waliwar a block lar - phase 2nd block lar pri.825.