Get complete information related to latest Burette Set Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Burette Set Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Burette Set Tenders.
Tender For corrigendum : rate contract for medicine - stainless steel abdominal hysterectomy set, n.s.v set (s.s), g.v set, self abdominal detractor, m.t.p set., vaccine carrier (small size), x-ray digitalisation with high-end cr system (with installation & 1 yers. warrenty) console software with mulitmodality work station the cr system should have advances workstation provided with 17" high resolution monitor, keyboard & ouse, with the fol., digital ultrasound machine colour dopler (high resolution ) with 4 probe, semi auto analyzer, fully automated bio-chemistry analyzertechnical specificationsthroughput-150t/hr (constant with both mono and double reagent)system function-random access/stat/batchtest method-end point, fix time, kinetic, (single/double reagents chemistry, mono/ bio-chromatic measurements)calculation methods-1 point linear, 2 point linear, exponential, logit log3p, logit log 4 p, logit log 5p, spline, line graph, k factorblank-reagent blank, sample blank, pre sample blank, pre reagent blanksample tray-40 position, sample volume :2-30 ui, 0.1 ul increment, micro cup, & test tube can be used for samplereagent tray-80 position, reagent volume: 20-300 ul, 1 ul incrementmixing system-teflon coated mixersample probe-1 needle with liquid detector, shock sensoroptics-halogen-tungsten lamp, absorbance range: 0-4.0 abs resolution: 0.0001 abs.diffraction photometry with wave length: 340, 405, 450, 505, 546, 578, 630, 700nm & 4 more optionswash station-12 step washing, 4 needle wash station, 1 dry pad, external needle cleaningcalibration-linear and non-linearqc-multi-level qc setup with levy-jennings graph and westgrads multi rules with mean sd, and cvwater consumption-not more than 6l/hrtemperature-reagent: 2-14 c (24 hr refrigeration), reaction cuvette: 37c 0.1 humidity- 80%system interface-usbpower requirement-ac 220v 10%, 50/60 hzdimensions-750 mm*560mm*530mm, hotair oven, binocular microscope (olampus), centri fuge machin (good quality), micropipette (0-50 microliter), micropipette (0-500 microliter), micropipette (0-1000 microliter), microtips (0-50 microliter), microtips (0-1000 microliter), bed side screen with cloth 1"round pipe with wheel, sponge holding (all size), artery forceps 6" curved, artery forceps 6" straight., artery forceps 8" curved, artery forceps 8" straight., artery forceps 4" straight., alliys tissue forcep (all size curved straight), mosquito forcep (all size curved straight), scissor 6 " curved (all size), scissor 6 " straight (all size), scissor mosquito straight. (all size curved, straight), diatheromy (machine), laparoscopic instrument full set (best quality), needle holder 8 "curved, needle holder 8 " straight, needle holder 6 "curved, needle holder 6 " straight, needle holder 4 "curved, needle holder 4 " straight, doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside, elisa reader with washer mechine with printer & ups., doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside ( best quality), fully automated chemiluminescence analyzer(clia) 1. system should be fully automated walk -away with continuous loading facility.2. analyzer should have able to perform thyroid, bone, cardiac, fertility, diabetes and anemia profile test.3. working principle of system should be micron super paramagnetic particles platform with alp labeled reagents and amppd substrate.4. must have 3 phase magnetic separation with precisely controlled temperature.5. analyzer should have photon counting detection mode with photomultiplier photo counter with led reference module.6. the analyzer must have vortex non-touch mixing which can reduce carryover., 7. throughput of the system should be more than 180 tests in a hour.8. system should have 15 reagents onboard with onboard 2 -8 nonstop refrigeration facility 9. system should have at least 50 sample positions and continuous loading facility.10. system should have cont
Tender For corrigendum : regents and consumables for sysmex coagulation ca 1500 analyzer at aiims bhopal - ca clean i(gsa-500a)-50 ml, ca clean ii(gsz-500a)-500ml, reaction tube su-40-3000/pack, cuvette suc-400a 3000/pack, sample plate sap-400a 50/pack, control plasma n 1mlx10, control plasma p -1mlx10, standard human plasma-1mlx10, pt-multi calibrator -1mlx6, la control high 1mlx6, innovance d-dimer controls 2x5x1ml, citrol 1e- 1mlx10, citrol 2e-1mlx10, citrol 3e -1mlx10, thromborel s 4mlx10, thromborel s -10mlx10, innovin(10:10nl) -10mlx10, innovin (10:4nl)-4mlx10, actin fs (10x 2ml)-, actin fs (10x10ml), actin (10x2ml), actin (10x10ml), actin fsl(10x2ml), actin fsl(10x10ml), calcium chloride-15mlx10, innovance d-dimer kit -4mlx3, factor ii deficient plasma-1mlx3, factor v deficient plasma-1mlx8, factor vii deficient plasma 1mlx3, factor viii deficient plasma-1mlx8, factor ix deficient plasma 1mlx8, factor x deficient plasma 1mlx3, factor xi deficient plasma 1mlx3, fbg determination kit 1mlx6, la 1 2mlx10, la 2 1mlx10, innovance vwf act 2mlx3, berichrom pc 10mlx3, pro c global -2mlx4, protein s ac -2mlx2, innovance antithrombin 2.7mlx4, berichrom a2-antithrombin 5mlx3, berichron plg 5 mlx3, berichron pai 4mlx3, berichron f xiii - 5mlx3, test thrombin reagent- 5mlx3, berichrom antithrombin iii 5 ml x6, vwfag -2mlx4, owrens veronal buffer 15mlx 10, multifibren u(10x2nl), von willebrand reagent -2mlx5, innovance free protein s ag - 4 ml x 3, berichrom c1-inhibitor 5mlx3, factor viii chronogenic assay kit 2mlx2, reagent cap l csl-400a 100-pack, reagent cap l csl-400a 200-pack, cap no.527 (kitno.106) 10/pack, cap no.528 (kitno.105) 10/pack, sld mini cup 500/pack, revohem arachidonic acid 3x0.625ml, revohen adp 3x0.625ml, revohen collagen -3x0.625 ml, revohen epinephrine 3x0.625ml, revohem ristocetin 3x0.625ml, trashboxlinercs2(tbl-400a) 1pack
Tender For e tender for procurement of kits, chemicals and reagents for two years from the date of award of contract (aoc) and its extension, if required - "rh +k phenotyping glass bead cassettestechnical specification:1.cassttes should contain 6 columns filled with glass bead as filtration media 2.1st column to 5th column should be prefilled with monoclonal antisera such as anti c, anti e, anti c, anti e, anti k respectively and 6th column is 'control' column. 3.peg should be present in the columns as enhancer to increase uptake of antibody 4. assay time should be as per manufacturer's guideline / brochure 5. mixed field reaction /double cell population should be detected " , "ahg poly specific glass bead cassettes technical specification:1. cassettes should contain 6 columns filled with glass beads filtration media 2. all column should prefilled with ahg reagent (anti igg , anti c3d)3. assay time should be as per manufacturer's guideline / brochure 4. mixed filled reaction /double cell population should be detected" , "blood grouping (forward & reverse grouping) glass bead cassettes technical specification: 1. cassettes should contain 6 columns filled with glass bead as filtration media 2. 1st to 3rd colums should be prefilled with monoclonal antisera with a serial of anti a, anti b, anti d respectively and rest 3 colums contain 1 for 'control' and 2 colums for reverse grouping with variable serial.3. peg should be present in the columns as enhancer to increase uptake of antibody 4. centrifugation time should be as per manufacturer's guideline5. mixed field reaction /double cell population should be detected" , "monoclonal antisera for extended rh+k phenotypinganti c technical specification:anti c sera should be monoclonal anti c sera should be compatible for conventional test tube method the potency titre of the antisera should not be less than 4." , "monoclonal antisera for extended rh+k phenotyping anti ctechnical specification:anti c sera should be monoclonalanti c sera should be compatible for conventional test tube method the potency titre of the antisera should not be less than 4." , "monoclonal antisera for extended rh+k phenotyping anti e technical specification:anti e sera should be monoclonal anti e sera should be compatible for conventional test tube method the potency titre of the antisera should not be less than 4." , "monoclonal antisera for extended rh+k phenotyping anti etechnical specification:anti e sera should be monoclonal anti e sera should be compatible for conventional test tube method the potency titre of the antisera should not be less than 4." , "monoclonal antisera for extended rh+k phenotyping anti k (kell)technical specification:anti k sera should be monoclonal anti k sera should be compatible for conventional test tube method the potency titre of the antisera should not be less than 4." , "panel for antibody 3 cell screening applicable to conventional test tube method and glass bead cassettes technical specification: 1. cell panel should be 2%-5% of rbc suspended in saline 2. cell panel should be compatible with both conventional test tube method and glass bead cassettes of column agglutination technology for doing antibody screening test3. cell panel should contain rbc with the antigens of extended rh, kell, duffy, kidd, lewis, mns etc blood group system4. dose depended antigens (like mns, duffy etc) should be present in homozygous as per criteria of antibody screening test 5. cell panel should be compatible for enzyme treatment 6. pack size should be as per manufacturer's guideline / brochure " , "panel for antibody 3 cell screening applicable to gel card technical specification:1.cell panel should be 0.8%-1% of rbc suspended in low ionic strength saline2. cell panel should be compatible with gel card of column agglutination technology for doing antibody screening test3. cell panel should contain rbc with the antigens of extended rh, kell, duffy, kidd, lewis, mns etc blood group system4.dose depende