Get complete information related to latest Burnt Transformer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Burnt Transformer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Burnt Transformer Tenders.
Tender For corrigendum : labour work for replacement of failed / healthy / augmentation / de-augmentation / damaged / burnttransformer with transportation charge under kothara sub division.
Tender For supply installation testing and commissioning of 03 nos. of current transformer,01 nos. of cable termination kit 11kv ht xlpe cable- 03 core, and 01 nos. of automatic float cum boost battery charger 110 v at wtp under chas municipal corporation
Tender For ramala supply of instrument spares - spares for instrumentation, 3/2 nc stem actuated valve 1/4, model no - dp045061, make - janatics, 3/2 nc stem actuated valve 1/4, model no - c7082, make - janatics, air filter regulator (afr), model no - frc156334 frc-1/2 (40micron, 10bar), make - janatics, air filter regulator (afr), model no - frc156334-a frc-1/2 (40micron, 10bar) auto, make - janatics, air filter regulator (afr), model no - ac20a-02g1-b, make - smc, air filter regulator (afr), model no - sb20k-4g-m6d/rgln, make - shavo, cable tie, size - 25mm, make - tycab, cable tie, size - 50mm, make - tycab, cable tie, size - 75mm, make - tycab, cable tie, size - 100mm, make - tycab, cable tie, size - 200mm, make - tycab, cable tie, size - 300mm, make - tycab, cable tie, size - 400mm, make - tycab, cat6 networking cable utp, make - d-link, cat6 connector, make - d-link, conductivity electrode coupling, make - instruments & systems, conductivity electrode sensor solenoid valve, make - instruments & systems, control transformer, model no - 2026/11171, make - formoplastic controls, control transformer, primary coil - 0-440-460--480v, secondary coil - 0-200-230v, make - ampturn, control transformer, part no - modctr750vast415-240 , make - modtech, control transformer, primary coil -0- 440v, secondary coil -0-230v, amp - 0.3, make - sahara, control transformer, part no - in405696, make - auma, control transformer, capacity - 3kva, make - stepup electronics, control transformer, capacity - 1.0kva, make - automatic electric, control transformer, capacity - 200va, make - modtech, control valve positioner, pvp - 1, make - pneucon, control valve positioner feed back card, sg4-20la, make - pneucon, control valve diaphragm a140, make - pneucon, control valve (gasket), model no - 110/pdc 030t, make - pneucon, control valve (gasket), model no - 110/pdc 055t, make - pneucon, control valve (gasket), model no - 110/pdo 140t, make - pneucon, control valve (gasket), model no - 110/pdo 055t, make - pneucon, control valve (gasket), model no - 880/pdc 095t, make - pneucon, control valve (gland packing), model no - 110/pdc 030t, make - pneucon, control valve (gland packing), model no - 110/pdc 055t, make - pneucon, control valve (gland packing), model no - 110/pdo 140t, make - pneucon, control valve (gland packing), model no - 110/pdo 055t, make - pneucon, control valve (gland packing), model no - 880/pdc 095t, make - pneucon, control valve (diaphragm), model no - 110/pdc 030t, make - pneucon, control valve (diaphragm), model no - 110/pdc 055t, make - pneucon, control valve (diaphragm), model no - 110/pdo 055t, make - pneucon, control valve (diaphragm), model no - 110/pdo 140t, make - pneucon, control valve (diaphragm), model no - 880/pdc 095t, make - pneucon, control valve (seal kit ), model no - qtf300e-74ri, make - pneucon, control valve rotary actuator (repair kit ), model no - sa-200-8322es53857, make - pneucon, control valve rotary actuator (repair kit ), model no - sa-150-8322es53857, make - pneucon, control valve rotary actuator (repair kit ), model no - sa-150-8322e-23859, make - pneucon, control valve rotary actuator (repair kit ), model no - sa-150-8322e-23858, make - pneucon, control valve rotary actuator (repair kit ), model no - sa-175-dp1021a-23578 , make - pneucon, control valve rotary actuator gearbox, model no - mor-1000, make - tpgears, control valve rotary actuator gearbox, model no - mor-450, make - tpgears, control valve rotary actuator gearbox, model no - mor-100, make - tpgears, control valve rotary actuator gearbox, model no - 251/sa150m0450, make - pneucon, control valve rotary actuator (seal kit), model no - scn-d-s-00 mf1-100 /500, make - rotex, current transducer, model no - rish con-i-5a-f-h-01a2-02a2-z-z-z, make - rishabh, contactor, part no - 3rh2911-1ha22, make - siemens, control unit battery, make - abb, dew point transmitter, part no - p1089948153, make - atlas copco, donnelly chute sensor, model no - ki-5002 ki-30
Tender For purchase of sports exercise physiology lap equipments - cardiopulmonary exercise testing system system should be compact can be used in laboratory operation and low maintenance costs and easy servicing. system should be state of the art computerized telemetry breath test analyzer for on-line breath by breath measurement of exercise test of respiratory system to measure following parameter: time, ve, bf(rr), hr, feo2, feco2, peo2, peco2, vo2, vco2, ve/vco2(eqco2), ve/vo2(eqo2), rq(rer), vd/vt, vo2/kg, vo2/kg/hr, met, watt(work), hr, ttot, ti, te, ti/te, ti/ttot, pef, pif, br, vet, sum, tv/te, o2 kinetics, oxygen deficit, oxygen debt parameters and indirect calorimetric. wireless hr recording system, indirect cardiac output by wassermann algorithm system should comply ats and ers guide line and it should be ce certified., iso certified system should have automatic ambient conditions measuring system. system should work under temperature range 0 to 50 celsius. system should have facility for automatic calibration of analyzers. volume transducer calibration with precision calibration syringe. system should meet following technical specification flow rate measurement: measuring headpiece should be either through turbine /dvt/ pneumotach and dead space less then 40 ml, it should not be affected by humidity , flow range +/- 18 l/s and accuracy 2% oxygen analyser : should be either electrochemicalcell/paramagnetic and measurement range 0- 100 %,response time t90 100 ms and accuracy +/-0,04 % and- resolution 0,02 %carbon dioxide analyser : should be ndir (infraredabsorption) and measurement range 0 - 10 %,-response time t90 90 ms , accuracy +/- 0,04 %, andresolution 0,02 % software should support latest windows or latest andin corporate customized predicted normal equations.software should be capable of changing graphics displays during real time testing. system should have facility for automatic treadmill or bicycle ergo meter control. should be supplied with software, standard accessories for operation manual carrying case for field use. system should be supplied with latest data acquisition system, deskjet printer and ups. system should comply en iso 13485:2003, en iso 9001:2000, ec certificate93/42/eec, programmable treadmill running machine with user terminal (display &keyboard) stand- alone and remote control via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 200 kg (440 lbs) speed range: 0-40 km/h elevation: 25% (14 maximum elevation) motorized adjustment, reverse belt rotation. motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v- belt, very quiet operation safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10to +40 degrees c, humidity 30 to 70% display (resolution): lcd display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs safety harness-1. indispensable accessory for stress testing, accident prevention and for the general safety of athletes.2. safety arch with different heights and widths to fit all running machines.3. an emergency stop at the crossbar of the safety arch allows automatic stop of the running belt in the moment a fall occurs.4. the harness and chest belt (available in 5 sizes: xxs, s, m, l, xl) secure the subject and prevents falling over to the front.5. chest belt straps do not pinch or restrict the athlete", programmable ergometer functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-assisted seat a
Tender For supply of replacement of 03 static freq converter one transformer rectifier unit one charger cum discharger c c - static frequency converter 208v 3ph 400 hz 60 kva , static frequency converter 115v 1ph 400 hz 20 kva , static frequency converter 36v 3ph 400 hz 5 kva , transformer rectifier unit 27v dc , automatic charger cum discharger ul 10 40v 40 amps