Web Analytics Made Easy - StatCounter

Bus Conductor Repair Tenders

Get complete information related to latest Bus Conductor Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bus Conductor Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bus Conductor Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40236918 Due date: 13 May, 202513 May, 2025 11.35 Lacs
Tender For special repair to e.i in ware house no. 6 and iii phase wiring in ware house no.-3 at rch campus namkum, ranchi.

Central Government/Public Sector

CTN :40237788 Due date: 24 May, 202524 May, 2025 10.00 Lacs
Tender For repair and maint of internal electric supply point wiring including submain wiring mcb db with connected accessories at hq igar east srikona

Central Government/Public Sector

CTN :40238527 Due date: 27 May, 202527 May, 2025 42.43 Lacs
Tender For special repair of internal wiring and other connected e/m work at kendriya vidyalaya no. 4 at jaipur mil stn under ge (s) jaipur

CTN :40228506 Due date: 27 May, 202527 May, 2025 NA
Tender For supply of all wheel hub greasing , all transmission oil change , rear both side brake wheel cylinder repair and brake system servicing , km assy repair and fitting work , all cable change , ele wiring checking and repair work

CTN :40218223 Due date: 10 May, 202510 May, 2025 30.0 Thousand
Tender For providing of repair and overhauling service - repair of tata safari:- mini fuse 20 amp ,wiper blade change, diagnosis wiring harness, wiper mechanism tata safari, wheel alignment with weight tata safari, wheel alignment & balancing.

CTN :40222106 Due date: 02 Jun, 202502 Jun, 2025 42.37 Lacs
Tender For supply of electrical materials for the repair and maintenance of street lights as per the boq - t-5 power/energy saver 2x24w choke, t-5 power/energy saver 24w ftl tuberod, 2x24 t5-holder, t5 power saver 2x24 fixture acrylic transparent cover, t5 power saver 4x24 fixture acrylic transparent cover, 150w hpsv choke, 150w hpsv lamp, capacitor 33mfd 250vac 50 hz, electronic ignitor suitable for 150w hpsv lamps, 150w holder, led driver 50w bis certified, led mcpcb plate 50w, led mcpcb plate 100w, led mcpcb plate 150w, supplyingof isi marked and approved make of moulded case circuit breaker(mccb) suitable for 3phase,3pole,50hz,415 volts, ac supply with respective interrupting capacity(ka) at 415 volts cited against their range standard conforming to is - 8828: 8.1mccb with breaking capacity 25 ka at 415 v: current rating -125 amps & 70% -100% adjustable, supply, installation, testing and commissioning of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light sub feeder panels - type 2 pluggable spd 3+1, rating l-n/n-pe uc 255/320 v in 30/60ka ka, lmax 30ka/60 ka, up 1.5kv, supplying of isi marked and accepted standard of miniature circuit breaker(mcb)ofcseries suitable for 240/415volts,50cycle,10 ka value ac supply confirming to is:8828:1996,iec:60898 :2002 but without enclosures: single pole 63 amp., astronomical timer with dst feature, contactor 3 pole 90 amp 50hz 415volts with no-nc contacts, tpn connector 150a, supply of approved make powder coated sheet steel encloser spn mcb db inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator): 8 way double door, supply, installation, testing and commissioning of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light - type 2 pluggable spd 1+1, rating l-n/n- pe uc 230/400 v in 5 ka, imax 10 ka, up 1.2kv, led batten tubelight 20w, supplying of approved make tpn mcbdb metal double door with provision for fpmcb/isolator/rccb/rcbo as incomer and sp mcbs as outgoing inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator ): 8 way (8+24), 8 sq.mm multistrand pvc insulated copper wire bundle 90mtr, 1.sq.mm aluminium single core wire bundle of 100mtr. isi marked, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 2-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 4-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 1-core isi marked with alu. stranded/solid conductor: 25sq.mm unarmoured, wooden ladder 21ft, toolkit set consisting of different sizes l-keys, screw drivers, testers and plier set., taperoll box consisting of 30pcs (conforms to is: 7809 (part 3, sec 1),self extinguishing,protects from electrolyt

CTN :40218970 Due date: 12 May, 202512 May, 2025 88
Tender For pump motor repair - guide vane, oil seal steel bush(oil seal sleeve), oil seal(pump oil seal), intermediate piece (i.p.) with i.p. leaded bronze bush, pump bowls, rewinding of motor of 20 hp, rewinding of motor of 17.5 hp, rewinding of motor of 15 hp, rewinding of motor of 12.5 hp, rewinding of motor of 10 hp, rewinding of motor of 7.5 hp, rewinding of motor of 5 hp, rewinding of motor upto 3 hp, transportation of pumping machinaries, motor base with pin, circlips(small), bearing (gun metal bush) centrifugal cost aluminium bronze bearing bush, studs and nuts, tip carbon/ferrode padding, thrust bearing block assembly (tb bottom), carbon housing(tb plate), lock ring(circlip big), lower housing, upper housing, lower flange, upper flange, labour charges (overhauling of pump only), brass filter, strainer, cable guard, pump coupling (stainless), pump key (stainless steel) upto 8 stages, pump shaft (stainless steel) counter less ground with key way upto 8 stages, allen screw, steel bush (i.d.o. ss sleeve), d.o. bearing( i.d.o lb bush), discharge outlet (d.o.) bearing(lb bush) and d.o steel bush(ss sleeve), impeller shell moulded with aluminium & bronze, supply and fixing of voltmeter, supply and fixing of ammeter, supply and fixing of led indicator, supply and fixing of wiring kit(sd upto 25hp), supply and fixing of wiring kit(dol upto 7.5hp)(mr), supply and fixing of no-volt (nv) coil, supply and fixing of terminal plate (connector 60a), supply and fixing of terminal plate (connector 30a)(mr), supply and fixing of ryb rotary switch(volt selector), supply and fixing of single phase preventer(20 to 30 hp), supply and fixing of single phase preventer(7.5 to 15 hp) (mr), supply and fixing of 15 amps relay (mr), supply and fixing of 23 amps relay (mr), supply and fixing of 33 amps relay, supply and fixing of 25 amps contactor, supply and fixing of 16 amps contactor(mr), erection of panel board & ms box (outdoor type) (gulbarga pred, pg.no.57, lt.no.12.2), supplying and fixing angle iron frame work fabricated out of m.s. angle iron and m.s. flat with bolt, washer etc and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mm (pwd ele sr 2014-15, pg.no.49, lt.no.6.39.3), refilling available earth around pipe lines, cable in layers not exceeding 20cms in depth, compacting each deposited layer by ramming after watering with lead upto 50m and lift upto 1.5m including cost of all labour complete as per specification pre sr 2011-12, p-3,1-6., labour charges for laying u.g. cable upto 3.5 core 25 sq.mm as per pwd electrical sr 2010-11, p-68,1-1, class a pvc cable, lifting of struck up submersible pump set above 300 ft (bwssb sr 2017-18/o150g/sl no.27), lifting of struck up submersible pump set upto 300 ft (bwssb sr 2017-18/o150g/sl no.26), labour charges overhauling, lifting of submersible pumpsets, re-errection charges of pumping machinery including overhauling and painting, cable joint, g.l. pipe threading including transportation, labour charges (for over hauling), supply and fixing of ct coil 50/5 & 75/5, supply and fixing of blade set 25a, supply and fixing of blade set 16a(mr), supply and fixing of hylum brand hand plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc and fixing of exciting wood or metal box using nf screw , supplying and fixing polished wood board made out of not less than 15mm thick planks at both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered wooden plugs screws etc, fabricating, supplying and mounting ms box made out 14 swg suitable for foor/wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front over equipped with temper proof locking arrangements with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enamelled metal paint etc., com

CTN :40234263 Due date: 17 May, 202517 May, 2025 7.77 Lacs
Tender For general annual maintenance contract 24 25 wiring maintenance maintenance and repair of electrical installations and replacement of damaged items at various pump house in thrissur district general electrical work

Central Government/Public Sector

CTN :40019296 Due date: 12 May, 202512 May, 2025 40.00 Lacs
Tender For corrigendum : maintenance, repair and replacement of unserviceable internal wiring and connected items in viman nagar, 509 area, akash nagar and chandan nagar at af stn pune under ge af lohegaon

Central Government/Public Sector

CTN :40221779 Due date: 24 May, 202524 May, 2025 48.97 Lacs
Tender For certain b/r works at 1 asd and maint services repair maint internal wiring at 39 fad bharatpur mil stn
 Loading, Please wait...

Connect us via What's Up