Get complete information related to latest Cable Glands Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cable Glands Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cable Glands Tenders.
Tender For set of safety bracket assembly of bp and fp end cocks for wag 9/wap-7 locomotives consisting of two items-- (i) ms plate for bracket assembly of bp and fp end cocks for wag-9/wap-7 loco s as per s.c. rly. drg. no.- c/els/lgd/ex.ftg/4/25 material: ms as per ls: 2062. note: thickness of the plate is 20mm instead of 16mm. qty.= 01 no. & (ii) ms channel of size 150 x 75 x 6 (430 mm long) al ong with ms plate of size 150 x 75 x 16 mm i.e. ms plate (ref: 2) to be welded to the channel (ref:1) a t one end as per s. c. railway drg. no.- c/els/lgd/ex.ftg/3/12 (alt.-1), reference no.- 1 & 2 qty.= 02 nos. (1 set= 2 items in 3 nos.) (04 set of sample to be got approved before bulk supply of material). [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : tender for supply of hea igniter system -hea igniter exciter box , hea igniter cable assembly , hea igniter retractor assembly , hea igniter flexible spark rod assembly , hea igniter spark rod tip , hea igniter guide pipe assembly , local panel , control panel , common manual isolation valve instrument air , air set and air manual isolation valve instrument air with copper tube and fitting from burner front , cooling air one and half inch hard rubber high temperature hose 1500 mm with end clamp , erection materials mounting hardware and other supporting materials cables glandscable lugs
Tender For corrigendum : supply of enclosures complying with nema 4x standard , m20 type cableglands fixed in the bottom of the boxes, 60 boxex with 6 cableglands and 60 boxes with 2 cableglands , plane abs or plastic mounting plate fixed in all the boxes , soft copy of serial numbers of the enclosure , charges for transportation of consignment to rmc chennai
Tender For supply of modified bracket assembly for safety sling for under slung compressor for three phase locomotives, as per drawing no. 1209- 02.427- 424, ref. no. 01 to 07. consisting 07 items in one per loco set as: (1) ref. no. 01 - plate 136 x 70 x 10 mm , qty - 08 number, (2) ref. no. 02 - pressed angle 65 x 50 x 10 mm thick (dev. length 98 mm), qty - 16 numbers, (3) ref. no. 03 - hex head bolt m12 x 80 mm long, qty - 08 number, (4) ref. no. 04 - m-12 spring washer, qty - 08 numbers, (5) ref. no. 05 - nylon nut hex m-12, qty - 08 numbers, (6) ref. no. 06 - wire rope dia. 8 mm, qty- 17 meters & (7) ref. no. 07 - wire rope clip (bull dog grip), qty - 32 numbers, in one set. material specification as per drawing. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cableglands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking