Web Analytics Made Easy - StatCounter

Cable Assembly Tenders

Get complete information related to latest Cable Assembly Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cable Assembly Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cable Assembly Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45475154 Due date: 07 Jul, 202607 Jul, 2026 30.00 Lacs
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get

Central Government/Public Sector

CTN :45461296 Due date: 07 Jul, 202607 Jul, 2026 45.00 Lacs
Tender For corrigendum : repair to security/ compound/ boundary walls, concertina coils, barbed wire and fencing/ iron works in tech area at af stn phalodi

Central Government/Public Sector

CTN :45713930 Due date: 20 Jul, 202620 Jul, 2026 22.00 Lacs
Tender For repair / maintenance and painting of boundary wall, security wall, fencing, barbed wire, concertina coil and other miscellaneous b/r items at af station bareilly under ge (af) bareilly

Central Government/Public Sector

CTN :45709067 Due date: 18 Jul, 202618 Jul, 2026 45.00 Lacs
Tender For repair replacement of internal wiring incl sub main wiring, mcb dbs, bldgs security lights and connected items in pocket 1 to 8 under ge roorkee - taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed., m&l for point wiring with 1.5 sqmm frls-h insulated, unsheathed, multistranded, 1100 volts grade copper conductor cable single core conforming to is:694 along with one run of 1.5 sqmm frls-h insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories / junction boxes / inspection covers etc of suitable size but not less than 20mm(od), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass gi screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., all as per item no 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch., all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one one light point controlled by two no. two way switch complete all as specified and directed, all as per item no. 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., m&l for sub main wiring along with earth wire with frls-h insulated copper conductor, single core cable drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(ph & n) + 1run x 4 sqmm(earth wire):- (note: three runs of copper cable and one run of pvc conduit shall be measured as one unit length), all as per item no 11 here-in-before but 2runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), all as per item no 11 here-in-before but 2runs x 10 sqmm(ph & n) + 1run x 10 sqmm(earth wire), all as per item no 11 here-in-before but 4runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), notes for item no. 2.00 to 14.00(i) quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) if any beam / column / rock wall is encountered while cutting chases, that particular portion may be provided with pvc casing & capping or surface conduit for drawing cables and surface pvc gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) no cutting shall be done on ceiling for laying pvc conduit for ceiling fan point wiring. surface conduit or pvc casing capping may be

corporations/Associations/Others

CTN :45702242 Due date: 07 Jul, 202607 Jul, 2026 17.03 Lacs
Tender For regular operation and maintenance of street lights (with material) at all industrial areas under riico ranpur kota(for 2 years) - regular operation and maintenance of high mast light in ranpur , kota including supply and replacing the required material and labour etc. complete as per the following terms and conditions:- i at any moment a minimum of 90% of total fixture must be in order. the defective fixture must be repaired within 3 days, falling which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate (accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor ). ii contractor shall arrange at his cost for put on & off the street light fixture at appropriate time regularly as per instructions of engineer-in charge. a register shall be maintained at riico/association office and complaint lodged must be attended by contractor within 24 hours. the person deputed by contractor shall attend the riico/association office daily and comply the instructions and attend complaints regularly. iii contractor will have to employ trained and qualified electricians for the work. iv corporation shall not be responsible for any kind of accident during execution of work. v contractor will be responsible for safety and security of fixtures and all concerned materials. vi contractor will be responsible for arrangement of all t&p required for the work vii cost of all labour and material like lamp / balllast wire etc. will be born by contractor. all material required for the work shall not be below the category-ii of concerned bsr item. contractor has to repair and maintenance of fixture with material in all cases like short circuit, phase to phase of jvvnl line etc. viii no extra payment will be made for fixing/removal of extra/existing fixture in the industrial area. ix contractor will be responsible for timely collection and deposition of electric bills of areas in each month. in case of delay in payment and jvvnl impose surcharge for delay payment the same will be recovered from the running bill fo the contractor. payment of electricity bill will be made by riico. x contractor will be responsible for rebate of timer provided by jvvnl. hence contractor will maintain the on/off system by timer properly. in case no rebate is provided by jvvnl due to failure of timer then rebate will be deducted from contractor payment. xi contractor will be responsible for any theft of electricity through poles and he will make necessary arrangements for this. in case of any theft is found suitable penalty will be imposed on the contractor. xii contractor will maintain cubical panel board and assessories fitted in it. in case of any fault repair/replace of material will be done by the contractor at his own cost. no extra payment will be made on behalf of material. xiii contractor has to keep ready total fixtures. in case of fault of fixture a penalty of rs.100/- per fixture per day will be imposed on the contractor., regular operation and maintenance of street light fixtures hpsv/ hpmv (70w/150w) in ranpur, kota including supply and replacing the required material and labour etc. complete as per the following terms and conditions:- i at any moment a minimum of 90% of total fixture must be in order. the defective fixture must be repaired within 3 days, falling which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate (accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor ). ii contractor shall arrange at his cost for put on & off the street light fixture at appropriate time regularly as per instructions of engineer-in charge. a register sh

CTN :45213812 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For corrigendum : supply of dma361070008 junction box , ek9938v-dma361070006 tranducer assembly , ek9938v-dpd360340155 extractor tool c spanner , ek9938v-dma361070015 re transmission unit , ek9938v-dma361070014 junction box , ek9938v-dsa361070151 cable assembly - 2 100mtrs , ek9938v-dsa361070152 cable assembly -5 15mtrs , ek9938v-dsa361070153 cable assembly -6 50 mtrs , ek9938v-dsa361070154 cable assembly -7 15 mtrs , ek9938v-dsa361070155 cable assembly -8 30mtrs , ek9938v-dsa361070156 cable assembly -9 2mtrs , ek9938v-dsa361070157 cable assembly -20 10mtrs , ek9938v-dsa361070158 cable assembly -13 15mtrs , ek9938v-dsa361070159 cable assembly -14 15mtrs , ek9938v-dsa361070160 cable assembly -15 15mtrs , ek9938v-dsa361070161 cable assembly -16 15mtrs , ek9938v-dsa361070162 cable assembly -17 15mtrs , ek9938v-dsa361070163 cable assembly -18 15mtrs , ek9938v-dsa361070164 cable assembly -19 15mtrs , ek9938v-dsa361070165 cable assembly -11 10mtrs , ek9938v-dsa361070052 master controller module assy , ek9938v-dsa361070053 engine module assy , ek9938v-dsa361070054 power supply module assy , ek9938v-dsa361070076 display module assembly , ek9938v-efs10002500l fuse, cartridge, 1a, 5x15mm,0229001hxp , ek9938v-efs20010000l fuse 2a , ek9938v-efs30012500l fuse, cartridge 3a, 32mm 6.3mm, 0326003hxp , ek9938v-eff-15020320f fuse cartridge 15a , ek9938v-xfnmec0384v1 cooling fan 48v dc, mec0384v1-000u-a99 , ek9938v-dsa361070109 controller and sdlc module assy , ek9938v- dsa361070108 resolver module assy , ek9938v- dsa361070110 pulse and serial module assy , ek9938v-dsa361070105 power supply module assy , ek9938v-dsa360980114 ba card , ek9938v- eff37502000l fuse 375ma , ek9938v-dsa360980120 kasu speed card assy , ek9938v-dsa360980121 power supply card assy , ek9938v-dsa361070047 dc linvar card assy , ek9938v-dsa361070055 display module assy , ek9938v-dsa361070086 cable assembly- 13a 15mtrs , ek9938v-dsa361070087 cable assembly- 14a 15mtrs , ek9938v-dsa361070089 cable assembly - 21 15mtrs , ek9938v-dsa361070091 cable assembly - 15b 15mtrs , ek9938v-dsa361070148 drc module assy , ek9938v-enf031420331 ms connector, ms 3106f-14s- 6s , ek9938v-enf031420333 ms connector, ms 3106f- 18-1sx , ek9938v-ent006f2219s ms connector, ms 3106f-22-19s , ek9938v-xcfre022038n cooling fan 230vac , type testing charges if any

CTN :45722155 Due date: 20 Jul, 202620 Jul, 2026 NA
Tender For tender for supply of 26bavc001 spares of atrx and uhf satcom terminal - uhf antenna los , 19 wired rack with shock mounts , lemo connector , control card , rf cable assembly set , led green , led red , display control card , fsu control card , pre controller module , driver amplifier , dual directional coupler 1 , two pole mcb , control card , display card , presure vent , o p cable , dual directional coupler , digital voice card , data control card , gps receiver card , dc dc converter , mother board , display control card , dc pc cables and connectors for 877 ekm submarine , battery 12v 65ah cots item , power supply 0 30v dual channel 10a , through line power meter , attenuator 500w , screw driver kit , attenuator 2kw , atu load test jig , rs232 can interface test jig , rs232 can interface test jig , vswr test jig 3 1 , slt 3003 software loading tool , swd 5000

CTN :45732204 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For supply of high voltage cable assembly for medha memu rake as per te connectivity part no.1-2317771-3 and te type no. : hvte-hdd-448 (abb transformer) [ warranty period: 30 months after the date of delivery ] ]

CTN :45255749 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For corrigendum : tender for supply of hea igniter system -hea igniter exciter box , hea igniter cable assembly , hea igniter retractor assembly , hea igniter flexible spark rod assembly , hea igniter spark rod tip , hea igniter guide pipe assembly , local panel , control panel , common manual isolation valve instrument air , air set and air manual isolation valve instrument air with copper tube and fitting from burner front , cooling air one and half inch hard rubber high temperature hose 1500 mm with end clamp , erection materials mounting hardware and other supporting materials cables glands cable lugs

CTN :45722241 Due date: 20 Jul, 202620 Jul, 2026 NA
Tender For x2/5995-000002, cable assembly special purpose electrical 4 conductors plug area free end and socket
 Loading, Please wait...

Connect us via What's Up