Tender For corrigendum : supply of 624kv surge arrester d d - supply 20ka nominal discharge 25mm per kv creepage 624kv single phase gapless zno sa complete with all acces corona ring sc ib lugs fixing and earthing hardware etc except tc and ic cable , supply 624kv terminal connector suitable for quad aac bull conductor , supply 624kv terminal connector suitable for al tube 4. 5 inch , supply insulated copper rod or strip or pvc insulated flexible coppercable connecting surge arrester to surge counter , spare 20ka nominal discharge 25mm per kv creepage 624kv single phase gapless zno sa complete with all acces corona ring sc ib lugs fixing and earthing hardware etc except tc and ic cable , spare 624kv terminal connector suitable for quad aac bull conductor , spare 624kv terminal connector suitable for al tube 4. 5 inch , spare surge monitor
Tender For corrigendum : design, manufacture, testing and supply of 06 nos of 66 kv, 40 ka class, sf6 circuit breaker with terminal connector suitable for al. tube/conductor with spring/semi pneumatic/pneumatic type operating mechanism and mounting structure etc. as per technical specification to various sub stations of hebbal division coming under the jurisdiction of transmission operation circle north, kptcl bengaluru - sf6 circuit breaker 66kv 40ka class
Tender For bid to ras supply of pvc flat cable, copperconductor with pvc insulation and sheath as per is 694 (q3) , led bulb with battery as per is 16102 (q3) , led bulkhead light (q3) , switch fuse unit (q3)
Tender For supply of 10.0 sq. mm. , frls, 3-core hrpvc flat cable, copperconductor with pvc insulation and sheath for working voltages up to and including 1100 volts three core, stranded pvc, type c heat-resistant cables (hr) as per is 5831 latest, type st2 cables sheathed with 85 degree celsius hrpvc compound to is 5831 latest, flexible isi marked cable with flexible ec grade copperconductor wire for submersible pumps as per is:694:2010 or latest. make: havells/polycab/finolex/nicco/ajanta/apar/kei
Tender For maintenance- repairs- replacement of electrical items for various projects executed under srinagar smart city limited for a period of 2 years. - supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage, delivery and erection of following sizes of distribution transformer at site., i) 630 kva distribution transformer, ii) 400 kva distribution transformer, iii) 250 kva distribution transformer, iv) 100 kva distribution transformer, v) 63 kva distribution transformer, fixing of fabricated gi angle/channel/flat/pole collars., fixing of galvanised nuts and bolts., supply, installation, testing, commissioning, insurance, unloading, carriage and delivery at site, laying, stringing and binding of conductor including joints with pg clamps of required following size of acsr conductor (0.1 /0.05/ 0.03), i) 100 sqmm acsr (dog), ii) 50 sqmm acsr (rabbit), iii) 30 sqmm acsr (weasel), supply, installation, testing, commissioning of ab (ht) cable of following sizes:, iii) 50 mm ab (ht) cable (3x50+1x70 mm ) xlpe(11 kv, 3c +earth), iv) 70 mm ab (ht) cable (3x70+1x95 mm ) xlpe(11 kv, 3c +earth), v) 95 mm ab (ht) cable (3x95+1x95 mm ) xlpe(11 kv, 3c +earth), vi) 120 mm ab (ht) cable (3x120+1x95 mm ) xlpe(11 kv, 3c +earth), mid span straight through jointing kit for 11 kv abc of following sizes:, i) 11 kv abc 50-95mm straight through jointing kit (3 core), ii) 11 kv abc 120-185mm straight through jointing kit (3 core), iii) 11 kv abc 240-300mm straight through jointing kit (3 core), heat shrinkable outdoor cable termination kit for ht/lt abc of following sizes:, i) 11 kv abc 70-95 mm outdoor cable termination kit, ii) 11 kv abc 120 mm outdoor cable termination kit, iii) 11 kv abc 150-185 mm outdoor cable termination kit, iv) 11 kv abc 240-300 mm outdoor cable termination kit, supply, installation, testing, commissioning of ab (lt) cable of following sizes:, ii) 50 mm ab (lt) cable ( 3x50 + 1 x 16 + 1 x 35) mm xlpe (1.1kv, 3+1 c, al), iii) 70 mm ab (lt) cable (3 x 70 + 1 x 16 + 1 x 50) mm xlpe (1.1kv, 3+1 c, al), iv) 120 mm ab (lt) cable (3 x 120 + 1 x 25 + 1 x 95) mm xlpe (1.1kv, 3+1 c, al), straight through cable jointing kit for lt abc of following sizes:, ii) 50 mm ab (lt)straight through cable jointing kit, iii) 70 mm ab (lt)straight through cable jointing kit, iii) 120 mm ab (lt)straight through cable jointing kit, dismantling, i) dismantling, stacking of 9/8 mtr st poles and transportation back to divisional store as per the instruction of electrical incharge., ii) dismantling of 0.03/0.05/0.1 acsr conductor and transportation to divisional stores (servicible), servo voltage stabilizer, i) supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 63 kva, 3-phase oil cooled servo (complete job), ii) supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 50 kva, 3-phase oil cooled servo (complete job), rmu, supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 4 way type,two isolators and two circuit breakers 11 kv, ring main unit ,sf6 insulated, out-door type, extensible type,breaking capacity 25 ka for one second with sf6 circuit breaker / vcb self powered with o/c + e/f relay comprising of a) 11kv 630 amp motorised isolator including earthing switches with making capacity 52ka, having mechanical on/off, earth indications with fault current indicator.b) 11kv ,400 amp motorised spring operated, circuit breakers with earthing switches, connecting the rmu to supply transformer. c). copper bus bar of 630 amp rating.d). 1 no numerical aux. powered relay having non directional o/c and e/f protection (for each ciruit breaker).d). the circuit breaker enclosures shall be outfitted with a communicable-type numerical (feeder p