Web Analytics Made Easy - StatCounter

Cable Duct Tenders

Get complete information related to latest Cable Duct Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cable Duct Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cable Duct Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45736234 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For supply of cable duct (cable tray -length 3 mtrs) to drg.no.lw44174, item-4 alt. 'c'. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45737434 Due date: 23 Jul, 202623 Jul, 2026 NA
Tender For supply & lnstallation of under frame cable duct & pipe mounting to drg. no. lwsczac7-l-002/col-l & ii. alt. j. for lwsczac, lwfac, lwcbac, lwaccw,lwaccn coaches. [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45730995 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For supply of cable duct a 45 cover,in standard slot grey, as per drawing: cat no cda45sg,packing instruction: as per standard packing. it should be ensured that item should not rub during transportation. the item should be packed with adequate strength. transit damage , if any , shall be at the cost of supplier. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

Central Government/Public Sector

CTN :45719686 Due date: 13 Jul, 202613 Jul, 2026 44.90 Lacs
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl

CTN :45738540 Due date: 21 Jul, 202621 Jul, 2026 NA
Tender For supply of 10 pair ug jf communication cable , station line module analog board , l3 poeplus managed switch with integrated sfp transceiver modules , 12 core sm ofc cable , hdpe pipe , 2 pair pvc telephone cable , cat 6 utp cable , pvc conduits including laying of cat6 cable and 2 pair pvc telephone cable 2000 mtrs , 24 port loaded cat 6 utp patch panel , rj11 rj45 i o boxes , 4 port spu lpu , 5a 0 25a glass fuses , cable route markers joint indicators , excavation of trenches cat 6 utp cable 2150 mtrs , laying of 10 pair armoured communication cable laying of hdpe pipe laying of ofc cable 3250 mtrs , fixing and dressing of 12 nos of 6u network racks , 24 port fiber liu , 9u network rack , ofc patch cords of 2m length , cat6 patch cords 0f 2m length , provision of additional structured cabling in 10 work centers of cas as per scope of work , shifting of network rack end termination of telephone and cat6 cables and dressing of all cables splicing etc in e f facility , 20 pair weatherproof telephone junction boxes , open stage hfa ip phones with perpetual gateway licenses , digital handsfree telephone cli , installation commissioning programming and testing of above all items and provision of additional structured cabling for 01 year for any newly added

CTN :45480570 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For corrigendum : repairing of cable duct with cement concrete, fixing of barbed wire for extra protection of yard (with concertina wire) from monkey menance and replacement of panther conductor with acsr zebra in 132kv yard and replacement of non-functional high mast

Central Government/Public Sector

CTN :45711103 Due date: 18 Jul, 202618 Jul, 2026 45.00 Lacs
Tender For repair/replacement of capacitor bank, sign board, fencing cable duct cover, route indicator and miscellaneous work at various sub station/installation at af stn gwalior.

Central Government/Public Sector

CTN :45382837 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking

Central Government/Public Sector

CTN :45709690 Due date: 21 Jul, 202621 Jul, 2026 NA
Tender For supply and installation of underframe cable duct and pipe mounting to drg no.lgs/eog7-l-002, col i & ii, alt j. for lgs & lsdd coaches. [ warranty period: 30 months after the date of delivery ] ]

State Government

CTN :45685997 Due date: 10 Jul, 202610 Jul, 2026 4.65 Lacs
Tender For repair to the existing cable duct in the station yard and other allied works at 220kv r/s sedam.
 Loading, Please wait...

Connect us via What's Up