Get complete information related to latest Cable Gland Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cable Gland Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cable Gland Scrap Tenders.
Tender For supply of 50 mfd capacitor,440v motor run, casing-plastic, terminal-copper wire. make- havells, epcos , bajaj, unitec, universal,kinjal,tibcon,falcon,l&t or equivalent [ warranty period: 30 months after the dat e of delivery ]
Tender For corrigendum : supply of electrical manpower - provn of manpower elect. mtce. and op. of ei a skilled manpower , b unskilled manpower capable to assist in all type of electrical works , wiring for 1.5 sqmm frls pvc insulated copper conductor single core cable a group c , wiring for group controlled 1.5 sqmm frls pvc insulated copper conductor single core cable a group c , wiring 2 x 1.5 sqmm plus 1 x 1.5 sqmm earth wire , supplying and drawing following sizes of frls pvc insulated a 3 x 1.5 sq mm , b 3 x 4 sq mm , sf of following sizes of medium class a 20 mm medium class pvc conduit , b 25 mm medium class pvc conduit , sf following modular switch socket a 5 slesh 6 amps switch , b 15 slesh 16 amp switch , c 3 pin 5 slesh 6 amp socket outlet , d 6 pin 15 slesh 16 amp socket outlet , e bell push switch , sf of following size modules a 3 module 100mmx75mm , b 4 module 125mmx75mm , c 6 module 200mmx75mm , d 8 module 125mmx125mm , e 12 module 200mmx150mm , supplying and drawing of utp 4 pair cat 6 lan cable , supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor , sf of a call bell ding dong type , b call bell wire less , c fan regulator electronic step type 220v 50hz , sf of following sizes of pvc casing and capping a 25mm x 16mm , b 32mm x 16 mm , c 50mm x 16mm , sf of wooden type extension board for operating of electrical apparatu , sf of following flexible pipe a 25 mm pvc , sf of following size pvc insulated a 3 x 1.5 sqmm , b 3 x 2.5 sqmm , c 2 x 1.5 sqmm twin flat cablewhite , sf of following led fittings a 9 slesh 10watt 6500k 600mm long led tube with battenbox , b 5 watt led down lighter fittings surfacerecess in round square shape , c 15 watt led down lighter fittings surface type , sf of fancy type engagement light fitting , sf of 20 watt surface suspended 1200mm long led batten , sitc of surfacerecess mounting following size led luminarie 34 w 2 x 2 led panel recess type , b 34 w 2 x 2 led panel surface type , c 4 36 watt led batten fitting , d 4 25 watt led batten fitting , sitc of heavy duty exhaust fan of 450 mm 1400 rpm , sf of following type heavy duty exhaust a 400 mm sweep 1350 rpm plastic body wall fan , b 400 mm sweep 1350 rpm padestal fan , c 150 mm sweep 1350 rpm fresh air fan , d 250 mm sweep 1350 rpm fresh air fan , e 300 mm sweep 1350 rpm fresh air fan , sf of following sizes aluminium raceway a 100 x 50 mm , sitc of dp sheet steel , sf 5 a to 32 a rating 240 slesh 415 volts 10 ka c curve mcb a single pole , b double pole , sf following isolator in the existing mcb a 40 a double pole 240 v , b 63 a double pole 240 v , c 63 a four pole 415 v , d 100 a four pole 415 v , sitc of 100a 16 ka tp mccb , sf following sheet steel mcb a 6 way 240v spn double door , b 12 way 240v spn double door , c 16 way 240v spn double door , d 4 way 4 plus 12 415v horizontal tpn double door , e 8 way 4 plus 24 415v horizontal tpn , f 4 way 4 plus 12 415v vertical tpn 200a tinned copper bus bar
Tender For electric cabling service - 3 phase heavy duty electric wiring xlpe insulated working voltage form 415 v to 11 kv as per is 1554 along with associated items and civil work as per schedule of work attached; copper and aluminium coth conductor material as per schedule of work-1 supply, laying and testing cable xlpe insulated ,screened, pvc bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 sq mm 3 1/2 core. rm 280 2 excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, or for shafts, wells, cesspits, manholes, pier holes, etc. and not exceeding 10 sqm on plan and getting out in soft /loose soil complete all as specified and as directed cum 60.75 3 returning filling including spreading leveling, watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and as directed. cum 60.22 4 removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed. cum 0.53 5 supply and laying ldpe pipes 50 mm dia with all fitting ,laid in ground for crossing the cables across the road by cutting existing road , under floor ,wall by cutting existing floor and making good the road /floor and wall surface after laying of pipe . rm 270 6 cement concrete 1:3:6 type c-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete for making foundation for mounting flood light /bollard light fitting/finishing of roads/floors etc . cum 4.05 7 m &l for cutting of road /floor surface 30cm girth, up 45 cm width for croosing the pipe line /laying of cable acroos the road all as specified and directed. rm 30 8 s & f distribution boards epoxy powder coated tp & n (vtpn mccb db) 8 way ,415 volts ,fabricated from minimum 1.6 mm thick crca sheet and fixed/ flush to wall and suitable for universal mounting with 250 amps fully insulated copper bus bar for each phase and 02 neutral shrouded bar ,2 earth bar and cable tie for cable management with reversible door for ip-43 db,s protection, suitable for fixing fp mccb 100/125 amps as incomer complete all as specified and directed. note: suitable mccb and outgoing mcbs will be measured separately under relevant items of this schedule each 1 9 s & f mccb ,4 pole 100 a , 415 volts with rupturing capacity 16 ka with thermal-magnetic release and adjustable overload setting of following capacity complete all as directed. each 1 10 s & f bus bar chamber with 4 nos copper busbar 150 amps including mccb 100a 16ka 415 volts each 1 11 s & f sub main wiring with 4x16 sqmm +1 x 10 sqmm run pvc insulated unsheathed frlsh cable 1100 volt grade, with multi stranded copper conductor drawing in concealed pvc conduit not less than 25mm dia complete all as specified and directed. rm 50 12 s & f sub main wiring with 2x4 sqmm +1 x 4 sqmm run pvc insulated unsheathed frlsh cable 1100 volt grade, with multi stranded copper conductor drawing in concealed pvc conduit not less than 25mm dia complete all as specified and directed. rm 200 13 s & f modular rectangular block for mounting,modular switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 175mm x 175 mm and 50 mm deep each 25 14 supply and fix modular switch 1 way 16a, 1 module with indicator lamp each 25 15 supply and fix modular socket 6a/16a, 2/3 pin combined 2 module each 25 16 material and labour for earthing with galvanised steel earth plate electrode 60cmx60cmx 6mm thick burried directly in ground (earth pit not less than2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 32 x 6 gi strip by means of nuts,bolts,check nuts & washers of galvanized iron or steel,protected by 15mm bore light grade galvanised iron pipe and connected to