Get complete information related to latest Cable Gland Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cable Gland Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cable Gland Tenders.
Tender For supply and installation of bbt from ha substation to materials movement area - design, manufacture and supply of sandwiched aluminium bus-bar trunking system 2000a capacity with canopy and all other accessories for successful installation work from ha substation to material movement area as per attached scope of work and technical specification., installation, testing and commissioning of sandwiched aluminium bus-bar trunking system 2000a capacity with canopy and all other accessories for successful installation work from ha substation to material movement area as per attached scope of work and technical specification., supply of 400a tap-off box with complete accessories as per attached scope of work and technical specification complete., installation of 400a tap-off box with complete accessories as per attached scope of work and technical specification complete., supply of 25x6mm copper strip, installation of 25x6mm copper strip, fabrication and supply of switchboard for 3phase 415v ac 50 hz system with incomer - 400a mccb 1 no, outgoings - 400a mccb 1 no, 200a mccb - 1no, 125a mccb - 1 no, 63amccb - 3nos and all accessories as per technical specification and scope of work, installation of switchboard for 3phase 415v ac 50 hz system with incomer - 400a mccb 1 no, outgoings - 400a mccb 1 no, 200a mccb - 1no, 125a mccb - 2 no, 63amccb - 2nos and all accessories as per technical specification and scope of work, supply of 3.5cx150sqmm a2xfy cable, installation of 3.5cx150sqmm a2xfy cable, supply of glanding and termination of 3.5cx150sqmm a2xfy cable, glanding and termination of 3.5cx150sqmm a2xfy cable, installation of 25x3mm copper strip
Tender For corrigendum : tender for supply of hea igniter system -hea igniter exciter box , hea igniter cable assembly , hea igniter retractor assembly , hea igniter flexible spark rod assembly , hea igniter spark rod tip , hea igniter guide pipe assembly , local panel , control panel , common manual isolation valve instrument air , air set and air manual isolation valve instrument air with copper tube and fitting from burner front , cooling air one and half inch hard rubber high temperature hose 1500 mm with end clamp , erection materials mounting hardware and other supporting materials cables glands cable lugs
Tender For corrigendum : supply of enclosures complying with nema 4x standard , m20 type cableglands fixed in the bottom of the boxes, 60 boxex with 6 cableglands and 60 boxes with 2 cableglands , plane abs or plastic mounting plate fixed in all the boxes , soft copy of serial numbers of the enclosure , charges for transportation of consignment to rmc chennai
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cableglands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking