Web Analytics Made Easy - StatCounter

Cable Jointing Pit Repair Tenders

Get complete information related to latest Cable Jointing Pit Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cable Jointing Pit Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cable Jointing Pit Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government / Public Sector

CTN :41012063 Due date: 23 Jul, 202523 Jul, 2025 9.17 Lacs
Tender For providing of custom bid for services - 9040c25c08 installation of protective aluminum gi sheet covering for power cable from etp guard pond h2so4 tank corner

Central Government/Public Sector

CTN :41019530 Due date: 14 Jul, 202514 Jul, 2025 NA
Tender For budgetary offer for supply of 6.6 kv power cable

Central Government/Public Sector

CTN :41017664 Due date: 17 Jul, 202517 Jul, 2025 NA
Tender For supply of set of cable connectors for battery box cable of make m/s. anderson (or) m/s. dowells (or) m/ s. aal (or) m/s. pps (or) gimota set consists of 4 items as follows. (1) pp120 housing (blue) cat no. 1321 of anderson power product or similar - 04 nos/set. (2) pp120 housing (red) cat. no. 1321g3 of anderson powe r product or similar - 04 nos/set, (3) heat sink, bottle shape with rib vg-style 156- 42-g for plugs black. po -x upto 4.5:1 (ug95343 to6 b 005 a) - 08 nos/set. (4) pp120 contact cat.no.1319 of anderson power produ ct or similar - 01 no/set [ warranty period: 30 months after the date of delivery ]

Central Government/Public Sector

CTN :41017667 Due date: 17 Jul, 202517 Jul, 2025 NA
Tender For supply of drag chain without cable drg.no. cks: ck25 ab 100, r100 model ck-25-253025.100 .make c ks,igus , insutech , power mech ,safe track .all authorised certificate also required. [ warranty period: 12 months after the date of delivery ]

State Government

CTN :40980726 Due date: 22 Jul, 202522 Jul, 2025 NA
Tender For upgradation of lt cable from dg to substation near gyne ward for providing backup power for gynae ot section and picu under bankura mechanical division, p.h.e. dte. dist- bankura

State Government

CTN :40980759 Due date: 22 Jul, 202522 Jul, 2025 NA
Tender For supply delivery and replacement of spares for sub-station at mandalkuli water supply scheme , raipur block under bankura mechanical division, phe dte. - "control transformer supply80 va, 240 v / 110 v", "aux contractor supply (4 no 4 nc)make: siemens / abb, coil voltage: 110 v ac", "pcb relay card supply for avr as per existing circuit ", voltage controller potentiometer (1k) supply, "1100 va ups supply output power wattage 660w or equivalent , input-50 hz , wide input voltage range 145-290 v, 2x 7.2 ah (or equivalent) battery , provides 30-90 min power back upmake: apc, input: 230 v ac", "240 sq. mm. x 3 core, 11 kv grade, indoor type, heatshrinkable end termination kit supply ", "240 sq. mm., 11 kv grade, indoor type, heatshrinkable kit jointing charges", "avr throughout inspection and control operation checking and rectification by opening the cover , checking the throughout circuits with aux. contractor replacement charges, pcb relay card with voltage controller potentiometer replacement charges, control transformer replacement charges, old ups replacement and new ups installation charges fixing of heat srinkable kit & other as per direction . ", supply and delivery of following spares for battery charger panel:, supply of 65 ah smf vrla battery with 6 nos cell, polyproplene container make: exide, consisting of 9 nos. 12 v batteries (model-ep 65-12 or equivalent), "charges for old defective battery rack by disconnection all the electrical circuit and fitting fixing of the new battery rack fittings,connection of all batteries checking otesting for a certain period. ", "supply of 2.5 sq. mm x 4 core cu armored cable forbattery charger panel to 3 panel vcb , as per is-7098 (part-i )", gland supply for 2.5 sq mm x 4 core cu armored cable, laying charges of 2.5 sq. mm x 4 core cu armored cable, "charges for glanding & socketing for 2.5 sq mm x 4core cable for battery charger panel: as per direcrion of eic", "supply and delivery of following spares for 400 kva, 11 kv/433 v, transformer-1 & 2:", oti (4 inch. dia) supply make: ptci, "wti (4 inch. dia) supply make: ptci", oti replacement charges, wti replacement charges, "supply of 2.5 sq. mm x 10 core cu armored cable for 3panel vcb to transformer-1 & 2 as per is-7098 (part-i ) ", gland supply for 2.5 sq mm x 10 core cu armored cable, laying charges of 2.5 sq. mm x 10 core cu armored cable , supply of 2.5 sq mm cu pin lugs , supply of 2.5 sq mm cu fork lugs, "charges for glanding & socketing for 2.5 sq mm x 10core cable of 400 kva, 11 kv/433 v, transformer-1 & 2: as per direction of eic", supply and delivery of following spares for single panel vcb:, 240 sq. mm. x 3 core, 11 kv grade, indoor type, heat shrinkable end termination kit supply, 240 sq. mm., 11 kv grade, indoor type, heat shrinkable kit jointing charges, 200-watt space heater supply make: reco, 230 v , "thermostat supplymake: elcon gold, model: mm-106,range: 30? c - 110? c, 15 amp., 230 / 250 v ac", "3 nos. space heater along with 1 no. thermostatconnection wiring charges as per direction of eic", supply and delivery of following spares for 3- panel vcb: , "240 sq. mm. x 3 core, 11 kv grade, indoor type, heatshrinkable end termination kit supply", "240 sq. mm., 11 kv grade, indoor type, heat shrinkablekit jointing charges", 200-watt space heater supply make: reco, 230 v , "thermostat supplymake: elcon gold, model: mm-106,range: 30? c - 110? c, 15 amp., 230 / 250 v ac", 2.5 sq. mm. s/c, 1.1 kv grade control cable supply for space heater and thermostat wiring , "2 nos. space heater along with 1 nos. thermostatconnection wiring charges for each panel as per direction of eic", "3 nos. space heater along with 1 no. thermostatconnection wiring charges as per direction of eic", attending the fault at mandalkuli, bankura district with carrying different testing, servicing kit/machine like insulating resistance checking machine (1 kv, 2.5 kv, 5 kv) 3 phase variac, current injection machine/ kit, voltage

State Government

CTN :40993026 Due date: 23 Jul, 202523 Jul, 2025 NA
Tender For supply of 11 kv power cable joint kit for khambhalia division.

State Government

CTN :40211092 Due date: 24 Jul, 202524 Jul, 2025 11.99 Lacs
Tender For corrigendum : providing of electric cabling service - the work of excavation & refilling of earth and laying of ht/lt power/control cable and supply and installation of heat shrinkable jointing kits as & when required basis at khep.

State Government

CTN :40565545 Due date: 19 Jul, 202519 Jul, 2025 21.54 Lacs
Tender For corrigendum : supply of capacitance type point level switch and spares for air compressors of 1x500mw gsecl ukai.(et-6004 c&i-6) - liquid level detector assembly, part no.pw4334c06001, electronic drain for intercooler (ewdi) along with solenoid for atlas copco make compressor part no: 2901146555, electronic drain after cooler (ewda) along with solenoid for atlas copco make compressor part no: 2901146551, valve core with conical spring of atlas copco make electronics water drain valve ewd- 330 (part of service kit no: 2901063300), electronic water drain model: ld203-24 v 50/60hz, 0.2 to 16 bar, 1 to 60 deg c, code: 2202815907, make: atlas copco, temperature sensor, atlas copco p/n: 1089057470., adaptor / connector & cable for temperature sensor for atlas copco make compressor part no: 1614812601, poppet d. c. valve (sbv11-10-c-0-24dgh) (24v dc), model code : 02-181220, make- eaton for eaton make hydraulic power pack in scr of 8, m. s. manifold block for sbv11-10 valve, model code : sbv11-10, make- eaton for eaton make hydraulic power pack in scr of 8

corporations/Associations/Others

CTN :41019897 Due date: 23 Jul, 202523 Jul, 2025 NA
Tender For erection of equipment structure earthmat and cable laying etc for enhancement of 2 x 16 mva 110/11kv into 3 x 16 mva 110/11 kv power transformer and additional gc arrangement in 11 kv side at existing sipcot ii 110/11 kv ss in salem operation
 Loading, Please wait...

Connect us via What's Up