Get complete information related to latest Cable Laying Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cable Laying Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cable Laying Tenders.
Tender For provision of stand-by diesel generator set of 750kva capacity with necessary cablelaying and installation of panels featuring auto transfer facility at elaau/dkae.
Tender For 9030c25c11 electrical and associated works for ht cablelaying and ht panel installation for implementation of gujarat refinery storm water adequacy recommendations.
Tender For construction of overhead m.s. bridge and allied civil works for electrical cablelaying works at kakdwip super specialty hospital, kakdwip, south 24 pgs.
Tender For corrigendum : 220 kv cable with accessories, cablelaying, erection of joints terminations of underground section of 220 kv yeida sec 18 -noida international airport 220 kv jewar-noida
Tender For corrigendum : supply of server software and vms cctv , server anpr , storage cctv , 4 mp colour outdoor ip ptz camera , 4 mp colour indoor ip ptz camera , 2 mp varifocal indoor 30 mtrs ir colour dome camera , 2 mp varifocal outdoor 50 mtrs ir colour dome camera , 2 mp varifocal outdoor 50 mtrs ir colour bullet camera , 2 mp varifocal indoor 30 mtrs ir colour bullet camera , 2 mp fixed indoor dome camera , 4 mp varifocal anpr bullet camera , 2 mp varifocal driver image capture bullet camera , 24 port layer 3 switch fully loaded , 24 port layer 2 switch fully loaded , 8 port layer 2 switch fully loaded , 8 port layer 2 switch unmanaged , 4 port layer 2 switch unmanaged , industrial grade managed l2 switch fully loaded , video wall , work station video wall , work station pc , laptop , kvm switch , joystick keyboard , ofc to lan media converter , 12 port lc duplex liu , 15 kva ups with battery , 1 kva ups with battery , server rack 42u , industrial grade junction box , 12 core ofc cable , sftp cat 6 data cable , 3 core 1.5 sqmm copper cable , 3 core 2.5 sqmm armoured copper cable , laying of cable , laying of cat6 or ofc cable , 32 mm dia hdpe pipe , 25 mm dia pvc conduit , 12 ft gi pole , 20 ft gi pole , gi pole , cctv console , road or hard rock cutting , integration of existing 240 camera , itc complete cctv system , maintenance charges during 02 years warranty , first year camc post warranty of 02 years , second year camc post warranty of 02 years , third year camc year post warranty of 02 years , fourth year camc post warranty of 02 years
Tender For providing of operation and maintenance of other machines and plants - operation and maintenance of other machines and plants - instrumentation contract for miscellaneous instrumentation jobs-10 installation of direct type pressure gauge, temperature gauge, rotameters, flow gauge,etc. including transportation from the wh/iw, necessary tubing, connection etc. but exclusive of supply of materials. 100 nos., 20 installation of direct type pressure transmitter, pressure switch, temperature switch, solenoid valve ( inch to 1 inch), ip converter, thermocouple, rtd, limit switch, position transmitter, vibration transmitter, proximity/ vibration probe, temp. transmitter,speed probe etc. including transportation from the wh/iw, necessary tubing, connection, cable glanding, ferruling, lugging etc. as applicable but exclusive of supply of materials. 320 nos., 30 installation of diaphragm/ remote seal type pressure gauges etc. with accessories including transportation from the wh/iw but exclusive of supply of materials. rating : upto 600# flange rating. 20 nos., 40 installation of diaphragm/ remote seal type pressure transmitter, pressure switch etc. with accessories including transportation from the wh/iw, mounting, connection, cable glanding, ferruling, lugging etc. as applicable but exclusive of supply of materials. rating : upto 600# flange rating. 20 nos., 50 installation of level switch, displacer type level transmitter etc. with accessories including transportation from the wh/iw, mounting, connection, cable glanding, ferruling, lugging/ termination etc. as applicable but exclusive of supply of materials. rating : upto 600 # flange rating. 10 nos., 60 installation of tank level transmitters radar/servo with accessories including transportation from the wh/iw, mounting, gi earthing,glanding,termination etc. but exclusive of supply of materials. 5 nos., 70 installation of instrument control valve with accessories including transportation from the wh/iw, mounting, tubing, connection, cable glanding, ferruling, lugging/ termination etc. as applicable but exclusive of supply of materials. valve size : upto 2"300# 20 nos., 80 cablelaying testing of frls armoured power/control/signal cables made trenches,cabletrays, pullthrough pipes or exposed on wall. beam/rakes; trussestie/beam or embedded in floor. unit rates quoted for installation of cables shall be same irrespective of route and method of laying. the rates shall include laying, pulling of cables, proper dressing of cables on cable trays, racks, vertical raceways and supply and installation of saddles, spacers and nylon chord for tying as required, identification tags at strategic points / every 50meter intervals, aluminium clamps with fasteners,etc. cable identification aluminium tags at strategic points/every 50meter interval for identification of cable;etc. complete. the straight through joints/tying with armour in the cables should be avoided and rate includes all leads and lifts from and to yard. meggaring to be done before laying of cables.laying of instrumentation/fo armoured cables/power cables including transportation,dressing , clamping (with aluminium clamp at 600 mm interval), tagging (engraved on ss plates with ss tiebelts), inclusive of supply of consumables like cable tie, aluminium clamp and cable tag : type and size: armoured , od : upto 0.5" ( approx.).exclusive of supply of cables, 22500 meter, 90 cablelaying testing of frls armoured power/control/signal cables made trenches,cabletrays, pullthrough pipes or exposed on wall. beam/rakes; trussestie/beam or embedded in floor. unit rates quoted for installation of cables shall be same irrespective of route and method of laying. the rates shall include laying, pulling of cables, proper dressing of cables on cable trays, racks, vertical raceways and supply and installation of saddles, spacers and nylon chord for tying as required, identification tags at strategic points / every 50meter intervals, aluminium clamps with