Get complete information related to latest Cable Terminal Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cable Terminal Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cable Terminal Tenders.
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl
Tender For corrigendum : repair to security lights panels dg sets fire alarm ups with covered items at af stn bikaner under ge (af) nal - excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m depth, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed by engineer-in-charge., removal of excavated material soils to a distance n exc 50 m and depositing where directed at a level not exceeding 1.5m above the startly point complete all as specified and directed., returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm as in any type of soil complete all as specified and directed., material and labour for sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed. note : punned thickness shall be measured for payment., material and labour for un-reinforced pre-cast concrete cable covers, class lv type-1, flat size 250mm x 150mm x 40mm thick complete all as specified and directed., taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 6 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 10 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 4 core, 16 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 25 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 35 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 50 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 6 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge , supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 10 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 4 core 16 sqmmlaid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 3.5 core 25 sqmm laid in trenches
Tender For bid to ras supply of xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1) (q2) , supply and fixing on load change over switch ss enclosure complete with capacity 200 amp, 415 volt, 4 pole, 50 hz. , supply and fixing sheet metal enclosure spn db double door having facility to fix mcb spn as incomer and mcbs as outgoing, spn 4 ways, ip-43 , supply and fixing sheet metal enclosure tpn db double door having facility to fix mcb tpn as incommer and mcbs as outgoing tpn 4 ways, ip-43 , supply and fixing bus bar chamber 100 amp, 4 way, 415 volts enclosurre is made from crca sheet of thickness 3.15mm crca sheet cover , supply and fixing of straight through epoxy cable joint kit incl jointing materials making joints of ug electric cable 1100 v grade nominal cross sectional area not exc.50 sqmm, 3.5 by 4 core , supply and fixing straight through epoxy cable joint kit incl jointing materials making joints of ug electric cable 1100 v grade cross sectional area 240 sqmm to 300 sqmm, 3.5 core. , supply and fixing end termination epoxy cable joint kit including jointing materials for making joints of ug electric cable 1100 v grade nominal cross sectional area 240 sqmm to 300 sqmm, 3.5 core , supply and fixing of galvanised iron pipe 100 mm bore dia light grade for protection of ug cable , supply of digging nad layingg in excavation trenches not exc. 1.50 m wide and not exc. 1.50 m in depth, complete all as specified and directed. , returning, filling in including spreading, levelling, watering and well ramming in layers not exc. 250 mm in soft loose soil , supply and fixing of galvanised iron pipe 40 mm bore dia light grade for protection of ug cable , supply, installation, commissioning and testing including providing all necessary electrical connection,lt feeder panel board of size 1.0 m x 0.6 m x ) /bid number : gem/2026/b/7568567 * /dated: 22-05-2026 & & / bid document 1 / 30 & & ' ' /item category 0.5 m , supply, installation, commissioning and testing including providing all necessary electrical connections lt feeder panel board of size 0.6 m x 0.6 m x 0.5 m , supply and fixing earhing complete with gi earth plate electrode of size 600x600x6mm thick.complete all as specified and directed in boq spec file , supply and fixing earhing complete with gi earth plate electrode of size 600x600x6mm thick. complete all as specified and directed in boq spec file , supply and fixing of sub-class b brick, well burnt, laid breadth-wise along the axis of cable laid in trenches over sand cushion laid for ug cable protection, complete all as specified and directed. , supply and fixing horizontal boring under a depth of 0.65 m from the gl for passing pipe upto 40 mm bore dia , supply of digging and laying of removing excavated materials soils not exc. 50 m and depositing where directed at a level not exc.1.50 m , taking down out unserviceable or serviceable lt ug cables of nominal cross-sectional area 300 sqmm including bricks, gi pipes etc. , taking down out unserviceable or serviceable lt ug cables of nominal cross-sectional area 50 sqmm 3.5 core including bricks, gi pipes etc. , supply of digging and laying of sand cushioning dry in trenches for protection of ug cables below, above and around the ug cable laid in trenches of 230 mm spread thickness , cutting road by hard standing and making good disturbed surfaces by using pcc type-c2,1-3-6 by using 40 mm graded stone aggregate , boring of holes under road,pavement,hard standing by trenchless technology using ultra sounding technique including hdpe pipe 150 mm dia suitable for 0.4 mpa working pressure , cutting chases, chipping in making good to facings, where required and pointing in cement mortar 1- 3 to ends or edges of landings, steps, sills, sunshades, shelves, lintels etc. , submain wiring comprising single core 2 runs of 6 sqmm nominal coss sectional area frlh
Tender For supply of consolidated requirement of electrical and other hardwares for nec - 40 w 220v 4 feet led tube light with fitting , 30 watt led street light luminaries with fittings , 18 w 220v 4 feet led tube light with fitting , 50 w led outdoor type flood light fitting outdoor type ip 65 , 200 watt led flood light luminaries with fittings , 70 watt led street light luminaries with fittings , 20 w 220 230 volt led bulb , 14 w 220 230 volt led bulb , 1.5 sq mm pvc insulated single core copper cable , 2.5 sq mm pvc insulated single core copper cable , 4 sq mm pvc insulated single core copper cable , 4 sq mm pvc insulated 2 core aluminium wire , 6 sq mm pvc insulated 2 core aluminium wire , 10 sq mm pvc insulated 2 core aluminium wire , pvc board 3 inch by 3 inch , pvc board 4 inch by 4 inch , pvc board 8 inch by 6 inch , pvc board 4 inch by 7 inch , pvc board 10 inch by 8 inch isi marked , pvc insulating tape 20 mm , cable vulcanising tape good qyality , silk tape h t grade good quality 20mm by 50 mtr , insulating varnish 3 .3 kv grade good quality , hot pouring compound 3 . 3 kv grade good quality , cold pouring compound 3. 3 kv grade good quality , empire tape 20mm by 50mtr , h t tape 11kv grade , cotton tape ht grade 20mm by 50 mtr , capacitor 42 mfd 230volt ac isi marked , capacitor 2.5 mfd isi marked iec standard , capacitor 10 mfd isi marked iec standard , mcb c series 10a sp with enclosure , mcb c series 20a,dp with enclosure , mcb c series 32 a dp with enclosure , mccb 32a dp 415v with enclosure , mccb 63a dp 415v with enclosure , mccb 160a 4 pole 415v with enclosure , mccb 630a dp 415v with enclosure , 16 amps 230 volts icdp main switch , 32 amps 230 volts icdp main switch , ictp main switch 415v 16 amps , ictp main switch 415v 32 amps , ictp main switch 415v 63amps , ictp main switch 415v 100 amps , ictp main switch 415 200amps , shackel insulator for 440v , lt pin insulator good quality well polished with pin porcelain , disc insulator 11kv grade , 3.3 kv pin insulator with pin and bolts , shackele insulator 3.3 kv grade,with bolt and strip , gut or stay insulator 11kv grade , 6 mm empire sleeve , 16 amps tumbler switch 230 volt , step type electronic fan regulator , 5 amps 5 oin flush type 5.5 combined isi marked ip 20 , 5 or 15a flush type s s combined isi marked ip 20 , s a 3 pin top , 15 a 3 pin top isi marked heavy duty , pendent holder good quality durable heavy duty , wood screw percentage , wood screw1.1 by 2inch , batten holder straight type , lighting arrestor 11 kv , 11 kv fix contact for goab switch , pneumatic timer coil 415v , timer set complete assy 415v , cableterminal kit 11 kv grade , cableterminal kit 3.3 kv grade , hand gloves 11 kv grade , 3 pole power contactor 32a ml2 type coil voltage 415v 2 no plus 2nc , 3 pole power contactor 40a ml3type coil voltage 415 2no plus 2nc , 3 pole power contactor 70a ml4 type coil voltage 415v 2no plus 2nc , 3 pole power contactor 450acoil voltage 415v 2no plus 2nc , 3 pole power contactor 200a ml10 type coil voltage 415v 2 no plus 2nc , spare contact kit for 3 pole power contactor 40a ml3 , spare contact kit for 3 pole power contactor 70a mla , spare contact kit for 3 pole power contactor 200a ml10 , acsr ferret conductor , acsr squirel conductor , exhaust fan 230v 300 mm , 5 by 6 amps 5 pin flush type socket , 5 by 6 amps flush type switch , 15 by 16 amps flush type socket , 15 by 16 amps flush type switch , ceiling rose , pvc plug 1 inch
Tender For corrigendum : supply installation testing and commissioning of pump unit and other electro-mechanical equipments at laripora pahalgam - supply, installation, testing and commissioning of submersible type pump sets with motors and allied mechanical and electrical components/ items as per manufacturer s recommendations and guide lines, and as per the scope of the work at site. the equipment supplied conform to latest is- standards and codes with fail safe circuits/ devices for(i) over loading (ii) under loading (iii) clogging (iv) shut off (v) low liquid level (vi) single phase prevention devices (vii) over heating etc. the pumping units shall have following technical specifications: pumps:type of pump :non clog centrifugal volute type sewage submersiblepumpscapacity= 28.4lpshead = 17.5 metres or abovesolid handling capacity: 20mm (minimum) quality of water: sewage water to be handled meterial of construction:pump casing : cast ironimpeller : stainless steelpump shaft : stainless steelmotor body : cast ironsealing : dual mech. seal...contd.. as per annexure-a, providing/supplying and fitting of 100 mm m.s flanged delivery main to be connected with existing rising main at site. the job includes providing and welding of m.s flanges 12 mm thickness. the flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. the cost on account of supply/ fabrication of bends and providing/ fitting of flanges is included in the job. (complete job)., providing and fitting of 100 mm dia ductile iron double flanged, non-rising spindle soft seated glandless gate/ sluice valves as per is14846 for regulating the water supply outside the pumping units p.n rating 1.0.the job includes providing and fitting of 02 nos. m.s flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with rising main of the pumping unit at appropriate spots as per site requirement (complete job)., providing and fitting of 100 mm dia ductile iron double flanged, slanted seat swing check valve( nrv) as per is 5312 p.n rating 1.0.the job includes providing and fitting of 02 nos. m.s flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with rising main of the pumping unit at appropriate spots as per site requirement (complete job)., gantry over sump :- fabrication, providing, fitting of ms gantry over sump with 02 nos. vertical columns. the gantry fabricated out of ismb-100, 3.25 mts long placed face to face. 300x300mm ms plates 12mm thick fitted on top and bottom side of column .bottom plate welded to the reinforcement of the sump and grouted in 1mx1mx1m pcc 1:1.5:3 mix. ismb-100,3mts long is to be placed and welded to the top plate of the columns .the job also includes providing and fitting of 2-tonne capacity chain pulley block with monorail along with hoisting chain (complete job)., providing and fitting of 50 mm23.5 core ,al pvc insulated cable, armouredfor internal connectionscrimping, taping etc. note:- the cableterminal ends for connection to switchgear at various requisite points shall be al. thimbles and of appropriate size and connected by hydraulic crimp tool only (complete job)., providing and fitting of 4-core 16 mm2 flat /circular submersible copper cable conforming to is: 694 (part 1st) 1964 & is: 694 (part 2nd) - 1964 for submersible pumping unit and other electrical equipment s. the cable connections terminal shall be fitted with copper thimbles of required size (complete job)., fabrication, providing and fitting of main electric control panel of appropriate size fabricated out of 14 swg sheet having required openings/vents and protection class : ip-55 & fitted with accessories as under: a) bus bar chamber: 160 amperes(tpn) b) main circuit breaker (incomer mccb) qty:- = 01 nocurrent rating = 160 amp. c) change over switch:qty. = 01 no.rating = 160 ampere....contd... as per annexure-a., electrification. providing/fitting of lighting and fan
Tender For bid to ras supply of self regulating heating tape cable e e - title1 , title2 , title3 , title4 , title5 , title6 providing self-regulating heat tape / resistance heating cable suitable for freeze protection of pipelines and utilities, having rated output of 35 w per meter at 220 v ac supply. the heating cable shall automatically adjust its heat output based on surrounding temperature conditions to prevent freezing and overheating. the cable shall be suitable for continuous operation in outdoor conditions, flexible for installation around pipelines, joints and valves, and compatible with temperature controller systems., providing m20 3-pin connector suitable for making secure electrical joints between self-regulating heat cableterminals, designed for reliable power and signal continuity. the connector shall be rated for operation at 220 v ac supply and compatible with heating cables of specified capacity. it shall ensure safe and firm termination, with robust insulation to prevent moisture ingress, short circuits, and electrical leakage.the connector shall be constructed from high-quality, weather-resistant materials, suitable for continuous outdoor operation under varying environmental conditions. it shall provide ease of installation, with a compact and durable design for use at pipeline joints, terminations, and interconnections. the m20 connector shall be compatible with temperature control systems and associated accessories, ensuring long-term performance, safety, and protection against overheating, corrosion, and mechanical stress., providing temperature differential controller with auto and manual operation, housed in a robust ip65-rated enclosure, suitable for controlling heat tracing systems to prevent freezing of pipelines and utilities. the controller shall be designed to automatically switch the heat tape on/off based on preset temperature ) /bid number : gem/2026/b/7550906 * /dated: 18-05-2026 & & / bid document 1 / 13
Tender For supply of customize fiber reinforced plastic made junction box of size 192x195x100 inch fitted with 1 ampere sp mcb breaking capacity 10ka , c curve type and 150 ampere 4-way cableterminal with necessary connections by 4 mm2 pvc frlsh wire ,and aluminum strip 2 nos size 2 fit. box make- sintex/cape/deepak or similar, mcb make-hager/schneider/seimens similar. [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of cableterminal copper lugs complete unit high conductivity 3 sq.mm. with yellow insulator to dowells cat.no.cvs-8372 or equivalent. [ warranty period: 30 months after the date of delivery ] ]