Get complete information related to latest Cable Trench Cover Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cable Trench Cover Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cable Trench Cover Tenders.
Tender For 1.provision includes laying of boundary stones in hed boundary at chethy fishing harbour 2.earthwork excavation for foundation for rcc post 3.topo survey of the area 4.provision of tree cutting for ensuring line of sight
Tender For raising of boundary wall towards 132 kv yard side repairing and painting work of yard foundation and supply and fixing of cabletrenchcovers at 220 kv gss manoharpur
Tender For construction of rcc boundary wall parallel to fencing at river side i/c 4 nos. sentry post at group center, crpf hiranagar at kootah, distt. kathua (j&k).
Tender For mgsy/25-26/teghra/01 - construction of h.l rcc bridge ( 6 x 21.750 m) in alapur to pasopur & l021 to pakthaul , ( khijir chak abm kirtoul ke bich balan nadi par pul ) under teghra block in the district of begusarai, excavation for structures , earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. up to 3.00 m depth ., levelling course for pile cap , providing and laying of pcc m15 levelling course 100mm thick below the pile cap., providing and laying reinforced cement concrete as per drawing and technical specifications clauses 800, 1205.4 and 1205.5 , rcc grade m -35 in pile cap, bored cast in situ piles r.c.c m-35 , pile excluding reinforcement complete as per drawing and technical specification and removal of excavated earth with all lift and lead up to 1200 m, supplying, fitting and placing hysd bar reinforcement in foundation complete as per drawing and technical specifications , tmt in foundation , refer bbs ,qty = 54.273+16.411+74.929+ 29.651= 175.264, 6mm thick. steel liner as per drawing and technical specification ., providing and constructing temporary island 16 m diameter for construction of well foundation for 8m dia. well. assuming depth of water 1.0 m and height of island to be 1.25 m including royality for earth @ rs. 3768.00 for each island., pile load test on single vertical pile in accordance with is:2911(part-iv) 1985, a) initial load test @ 2.5 times load on 1 pile, b) routine load test @ 1.5 times load on 2% pile, c) lateral load test, confirmatory boring at abutment and pier location, back filling behind abutment, wing wall and return wall complete as per drawing and technical specification, providing and laying of filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of morth specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification., plain/reinforced cement concrete in sub-structure complete as per drawing and technical specificationsheight upto 5m , rcc grade m30, plain/reinforced cement concrete in sub-structure complete as per drawing and technical specifications ,rcc grade m30 , height 5m to 10m, supplying, fitting and placing hysd bar reinforcement in sub-structure complete as per drawing and technical , reinf qty = 20.810+28.454+1.762+0.313+1.289+1.139 =53.77, providing weep holes in brick masonry/plain/ reinforced concrete abutment, wing wall/ return wall with 100 mm dia ac pipe, extending through the full width of the structure with slope of 1v :20h towards drawing foce. complete as per drawing and technical specifications, supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to irc: 83 (part-ii) section ix and clause 2005 of morth specifications complete including all accessories as per drawing and technical specifications., furnishing and placing reinforced/prestressed cement concrete in super-structure as per drawing and technical specificatio,rcc grade m 30, height 5m to 10m, reinforeced cement concrete m30 grade approach slab including reinforcement and formwork complete as per drawing and technical specification, pcc m15 grade leveling course below approach slab complete as per drawing and technical specification, construction of rcc railing of m30 grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical rcc post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space b
Tender For z.o.xiv.c.no.e1/3572/2025 providing chain link fencing with rcc post for proposal of road side park at periyar salai jn with netaji nagar main road in dn-184,unit-41,zone-14