Get complete information related to latest Cable Trench Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cable Trench Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cable Trench Tenders.
Tender For corrigendum : repair, maintenance of 11kv goab switch, laying and handling of ht and lt cables, trench cutting, tree trimming, installation mccb switches, making/ connection of earth pits with required accessories and electrification of switch room at quarry no. 0
Tender For corrigendum : external electrification work and cabletrench work 450 x 600 mm at home guard, palamu in the district of palamu. - external electrification work and cabletrench work (450 x 600 mm) at home guard, palamu in the district of palamu.
Tender For construction of additional 1no 22kv bay for interconnection of 43 bn itbp police kalna (nogli ) civil works for vcb foundations, isolator/ bus bar/ disc insulators, cabletrench ,ct cover ,earthling chamber ,gravelling etc. by providing cement co
Tender For repair and maintenance damaged 11/0.415 kv cable and electrical breakdown including fault detection, localization, rectification underground cable network offrs md accn, cwe delhi cantt office at kabul line and associated area under age sldc e/s und
Tender For estt. for repair of burst overhead ab cable of 11 kv bhagat singh chowk feeder near dr. rakesh gupta hospital at shanti nagar under clz city dn. east raipur. 78-028-5145-25-0027 dt. 15.01.26. r45028250656. (o&m-177-i)estimate for replacement of damage lt pole at various location, under tikrapara zone city dn. west raipur. 78-33p-5146-25-0038 dt. 19.01.26. r4633p250313. (33p-182-i)estimate for 03 straight through jointing kit for underground xlpe cable in 11 kv kailashpuri feeder from 33/11 kv sport complex substation under lakhenagar zone city dn. west raipur. 78-33p-5146-25-0045 dt. 19.01.26. r4633p250444. (33p-189-i)estimate for maintanance of faulty/bhrust ug 11 kv lohar chowk purani basti raipur under lakhenagar zone city dn. west raipur. 78-33p-5146-25-0042 dt. 19.01.26. r4633p250349. (33p-186-i)
Tender For corrigendum : emergent work in cabletrench of demolishing of rcc slab and cc pavement on cabletrench rising of side wall of cabletrench, rcc m-25 cover on trench, cc pavement and other miscellaneous work in ddu college, sector-03, dwarka, new delhi during 2024-25 sh- s
Tender For work of providing electrical repairing material for led lights installed in the municipal area. - providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed un-arrmoured aluminium cable confirming to is:1554 p-i/is:7098 p-1 of 1.1 kv with h4- grade electrolytic aluminium conductor confirming to is 8130 of purity >99.6%, inner / outer sheath confirming to is:5831 in existing rcc/hume/stoneware / pvc pipe/open duct/cabletrench / cable tray (with cable tie) including testing etc. as required of following size. oem must have it's own in house nabl accrediated laboratory for testing procedure as per is:10810. for additional technical parameters of product / work refer annexure 'a' attached with this bsr 1 6x 2 sq. mm. (insulated) , providing & fixing of 240/415 v ac mcb with positive isolation ka breaking capacity (b/c/d tripping characteristic as load and site requirement) 4 kv impulse withstand voltage, isi marked is 8828(1996)/conforming to iec 60898-1 2002, iec 60947-2, low watt losses, trip free mechanisum, energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm., conductor line load reversibility, ip 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 a rating and 10,000 upto 63 a, 5000 for 80 a & above rating including making connections, testing etc. as required. oem shall have submit nabl/cpri / erda accrediated lab type test reports & all as per pre approved by engineer in 0.5 a to 5 a ratin , double pole mcb(with b/c curve tripping characteristics) , four pole mcb (with b/c curve tripping characteristics) , supplying and fixing of aluminium (iec 60105 iso 209-1,2) / copper (iec 60028) bus bar by means of smc / dmc type insulator with standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending, cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. all as per pre approved by engineer in-charge. for additional technical parameters of products/work, refer annexure "a" attached with this bsr. , main panel street light control panel commissioning kiosk type weathe proof panel out door main cubic panel size 750x1250x500 they shall be in two section comaring as follows bsr 2017 (59.57) , supply & drawing wiring for sub mains isi marked (is:694) 110volts grade pvc insulated flat twin core sheathed solid aluminium 4 sq mm 2 core flat
Tender For construction of additional brick outdoor cabletrench and allied civil works at 33 kv s/stn. dhbvn sangatpura (jind) - dnit for the work :- construction of additional brick outdoor cabletrench and allied civil works at 33 kv s/stn. dhbvn sangatpura (jind)