Get complete information related to latest Cable Trenching Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cable Trenching Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cable Trenching Tenders.
Tender For supply of sitc of addressable main fire alarm panel , sitc of repeater panel , sitc of addressable photo thermal detector , sitc of addressable manual call point , sitc of addressable horn cum strobe , sitc of fault isolator , sitc of addressable fire control module , sitc of response indicator , supply and laying of 2x1.5 sqmm fire alarm armoured cable , sitc of mcp signage , sitc of relay module
Tender For tender for supply, installation testing and commissioning of it & electrical components for vams - supply and installation of 12u rack, supply and installation of 12 port managed n/w switch, supply and installation of 8 port managed n/w switch, 4+2 poe switch for power up the ip camera, supply and installation of gigabyte media convertor, supply and installation of patch cards, supply and installation of power jb, supply and installation of control jb, supply and installation of long-range wifi router, supply and installation of 6c sc ofc cable, supply and laying of 3c*2.5 sqmm armoured cable, supply and laying of cat-6 cable, supply and installation of 42 u rack, supply and installation of 24 port managed switch, supply and installation of pdp pannel, supply and installation of p10 display unit with 2 feet, * 6inch for driver information purpose, supply and installation of 10kva ups 3phase in, 1phase out with redundant setup, supply and installation of smf battery 42ah, supply and installation of battery stand and interlinks, flp gland, non flp gland
Tender For bid to ras supply of flexible copper trailing cables d d - item 10 , item 20 , item 30 , item 40 , item 50 , item 60 cable,trg,atc,3.3kv gr,3.5cx50mm2,is9968 size & tvpe 3.5cx50 sq. mm 3.3 kv grade flexible atc conductor of class-s, epr le-3, insulated &black hofr nbr pvc type se-4 sheathed flexible trailing cable suitable for reeling/un-reeling operation. cable type- flexible, standard: is 9968(part 2) 2002 d.c. resistance at 20deg. c (ohms/km) power core max- 0.393 earth core max - 0.795. annealing test in %- (before stranding) 13.5 %. per sulphate test in g/m2- max. 5.00. conductor screeninq power core only material approx thickness mm - extruded semiconducting compound/ extruded semi conducting tape- 0.80. conductor material: annealed tinned copper, 6.6 klv grade, cable type: flexible, standard: is 9968(part 2) 2002 tests on insulation thickness (nom) mm core ldentification - power core-2.20 colour rpct red, yellow & blue for power cores & green for earth core tensile strength before ageing n/mm2- min.4.20 % variation after ageing (air oven)- max. +-30% % variation after ageing in (air-bb)- max. +- 30%. elongation before ageing in % - min.200% % variation after ageing (air oven)- max. +- 30% % variation after ageing in (air-bb)- max. +- 30%. hot set test hot set elongation- 175% permanent set 15%. lnsulation resistance constant (min.) m ohm km. at 27deg.c- min. 3670 at 90 deg.c-min 3.67. thick of lnner sheath min 2.00 mm. rein forcement- open braid of textile material physical test on outer sheath thickness (nom) / min mm- 3.50/ 2.60 colour black, over all diameter of cable mm- 52.00+-3.00. tensile strength ) /bid number : gem/2025/b/6811700 * /dated: 24-10-2025 & & / bid document 1 / 22 before ageing n/mm2 - min. 11.0 at 2oo elongation 4n/ sq. mm. % variation after ageing in (air-bb)-max. +- 50% elongation before ageing in %- min.250% % variation after ageing in (air-bb)- max. + 50%. hot set test hot set elongation- max.175% permanent set- max 15. oil resistance test variation in % in tensile strength- max. +-40% variation in % in elongation-max. +-40%. tear resistance in n/mm - min.5.0. flammability test period of burning after removal of flame- max. 60 sec. min unaffected portion from the lower edge of the top clamp - min 50 mm. test high voltage at room temp- 10 kv ac for 4 hours. water absorption test increase in capacitance 1 to 14 days max- 6% 7 to 14 days max- 2.5%., control trailing cable 12 c x 2.5 3 p x 1.5 (pair screened) 2 voltage grade 1.1 kv 3 reference standard generally confirming to is: 9968 (part- 1)1998 4 conductor a. material to is:8130/84 annealed tinned copper b. nominal area of cross section(sq. mm) i)-unscreened core (sq. mm.) 2.5 ii) - screened pair (sq. mm.) 1.5 c. flexibility class as per is:8130/84 class-5 d. maximum dc resistance of conductor at 20 deg. c i)-unscreened core (ohms/km) 8.21 ii)- screened pair (ohms/km) 13.7 5 insulation i) material epr type ie-2 to is:6380/84 ii) nominal thickness (mm) 1.0 6 two cores of 1.5 sq. mm. size twisted together to form a pair yes. 7 individual pair screening each pair of 1.5 sq. mm. size taped with rpct, screened with 0.2 mm nom dia of annealed tinned copper wires braid, taped with melinex tape. yes. 8 no of cores / pair i)-unscreened cores 12 ii)-screened pairs 3 9 identification of power cores by number printing on cores. 10 laying up (i) three screened pairs laid up together, taped with rubber proofed cotton tape to form group as "a" (ii) 12 unscreened control cores laid up together around group as "a" of screened pairs and taped with rubber proofed cotton tape applied with open spiral. 11 inner sheath a) material to is: 6380/84 hd hofr csp type se-4 b) minimum thickness (mm) 1.6 12 an open braid of nylon cord reinforced in between inner and outer sheath. yes. 13 outer sheath a) material to is: 6380/84 hd hofr csp type se-4 b) nominal thickness (mm) 2.5 14 nom. overall diameter of cable (mm) 33.0 tolerance on nom. overall dia
Tender For work of dismantling of existing foac cable and laying, installation, splicing and commissioning of fibre optic approach cable (dwsm - dual window single mode, 24f & 48f) with supply of hdpe pipe, hardware like ties/clips/cleats, conduits, supports, fittings, accessories due to shifting of equipments from old control toom to new control room at 220kv jambuva s/s under jambuva am division under jambuva circle
Tender For corrigendum : supply of ip based 5 mp dome network camera with 128gb sd card , ip based 5 mp bullet network camera with 128gb sd card , 16 channel nvr with 4k support and three numbers of 10tb hdds , 24 inch led monitor for nvr , client pc with 32 inch led monitor , 1kva offline ups , enterprise grade network switch poe 24 port gigabit, 4 sfp ports , cat6 stp outdoor cable bundles 305 meters each bundle , biometric finger print, card and pin based access control device , exit switch. , em lock. , high frequency hid proximity pvc access card , laptop for maintenance , 25 mm dia, 16 swg isi marked pvc conduit with accessories , power supply db box and mcb with accessories , pvc casing and capping 1 inch and 2 inch, 100 meters each , installation, laying, testing and commissioning of above items to the scctv and access control system as per specifications
Tender For construction, testing and commissioning of r.c.c. elevated service reservoir of 85 kl capacities & staging 12 mtr. including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber, construction of 25k.l. capacity r.c.c. sump well,&providing, laying, jointing, interconnection, testing and commissioning of 90 mm dia pvc class 10 kg/sqcm 1056 mtr, 90 mm dia pvc class 6 kg/sqcm 134 mtr, 110 mm dia pvc class 6 kg/sqcm 359 mtr with suitable joints valve specials and all fittings including all allied civil works , supplying & installation of energy efficiant five star bee rating isi marked required capacity single phase, 50 hz, 415v, deep well submersible pump steel body, suitable for 6" tube well with control panel starter suitable for submersible pump with dry run protection, single phase preventer, connections, including clamps, bore cap etc. as required as per specifications but excluding pipe connection cable including verification of tubewell yield & electric connection from cseb, submersible pump for sump well, construction of brick masonry switch room of size 1.2*1.2*2.4 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection (f.h.t.c) in individual households and government institution etc. complete with trial run operation & maintenance for 06 months under retrofitting of water supply scheme under jal jeevan mission for village farfaud, block arang district – raipur. (balance work)
Tender For construction, testing and commissioning of r.c.c. elevated service reservoir of 90 kl capacities & staging 12 mtr. including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber&providing, laying, jointing, interconnection, testing and commissioning of 90 mm dia pvc class 10 kg/sqcm 305 mtr with suitable joints valve specials and all fittings including all allied civil works , supplying & installation of energy efficiant five star bee rating isi marked required capacity single phase, 50 hz, 415v, deep well submersible pump steel body, suitable for 6" tube well with control panel starter suitable for submersible pump with dry run protection, single phase preventer, connections, including clamps, bore cap etc. as required as per specifications but excluding pipe connection cable including verification of tubewell yield & electric connection from cseb, construction of brick masonry switch room of size 1.2*1.2*2.4 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection (f.h.t.c) in individual households and government institution etc. complete with trial run operation & maintenance for 06 months under retrofitting of water supply scheme under jal jeevan mission for village chaprid, block arang district – raipur. (balance work)
Tender For corrigendum : group -c (viramgam) combined station works for supply, installation, testing and commissioning of rtg system - %gst for the tenderplease select the rate of gst in cell ay13. rate selected shall be applicable for all the items under boq., group-c viramgam, cable laying - laying of all type of cables lt (pvc / xlpe / armoured/unarmoured/power/ control/ power cables lt : od upto 20 mm, sjb- explosion proof & weather proof signal junction box, pjb- explosion proof & weather proof power isolating switches junction box
Tender For corrigendum : repair of pump chamber ohsr water works and old house connections new automated water controller chlorinator control panel submersible cable providing and laying pipe line and sluice valve etc