Get complete information related to latest Cables Trenching Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cables Trenching Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cables Trenching Tenders.
Tender For providing of custom bid for services - laying plb pipe duct and associated works by hdd trenchless technology open trench method optical fibre cable pulling blowing and splicing works etc under new replacement plan for aurangabad business area of maharashtra cir..
Tender For corrigendum : providing of custom bid for services - pune laying of plb pipe duct and associated works by hdd trenchless technology or open trench method optical fibre cable pulling blowing and splicing works etc under new replacment and rehabilitation plan for optical fiber cable route of pu..
Tender For supply of supply 100mm m s pipe isi mark including flange nut bolt rubber , supply and fixing of jointing delivery line to main with material , supply and fixing 100mm size c i m s bend with all attachment complete , sf 100mm ci tee with all attachment , supply and laying of 100mm ms with flanges nut bolt packing etc , supply of 100mm dia of hand wheel operated with sluice valves destination including all taxes and insurance , supply of 100mm hand wheel ci double flanged valve operated with sluice valves destination including all taxes and insurance , supply and fixing 100mm size fire attend with pipe line attached , ci pipe 110mm leakage work complete , nalkup lowering and lifting work with include lifting machine fitting valves coupling and nut bolt , l e d plate , l e d sisa , sandf of 6 amp to 32 amp spmcb 10 ka c curve , supply and wiring of submains with 2 nos 25 sq mm frlsh pvc 1100v single core multistrand copper cable in existing conduit complete with all materials labour tandp as directed by engineer in charge , supply of electric power contactor 32 ampere 03 pole ac maximum power 21 w 400v , supply of electric power contactor 63 ampere 03 pole ac maximum power 21w 400v , supply of pvc electric tap grill roll multi colour , supply of onoff vintage bakelite light black switch 2way 06 amp to 16ampere 240 vol , sandf of 63 amp 4pole change over switch on 40x40x6mm angle iron frame including cost of labour tandp painting and material required for completion as per direction of engineer in charge , supply and laying of 06sqmm 2core al pvc insulated armoured cable 1100v in existing masonry open duct including proper earthing connection with clamps etc complete as directed by engineerincharge , supply and wiring of submains with 2 nos 06 sq mm 2core frlsh pvc 1100v single core multistrand copper cable in existing conduit complete with all material labour tandp as per engineer in charge
Tender For bid to ras corrigendum : supply of camera with housing , anticutting fence with concertina , pids with vms , media convertor , poles , patch chord scpc scpc , joint closure aerial box , patch chord lc , lan cable drum dlink , power cable , fibre cable , duct 33 by 40 mm , miscellaneous close enclosures heat sleeves clamps nail bolts sockets etc
Tender For supply of m l for point wiring with pvc insulated unsheathed single core multi stranded copper conductor 1 5 sqmm 1100 volts grade cable frls passing through pvc casing caping including accessories , one 3 pin switch socket combination 5 amps on the same board with other switches 28 points , one 3 pin switch socket combination 5 amps independent 30 points , one bell point controlled by one push button 4 points , all as per item no 1 above but with 2 5 sqmm cable for one three pin 15 amps socket out let controlled by one switch 18 points , s f modular switch 1 module single pole one way 6 amp conforming to is 3854 and isi marked complete all as direcred 84 nos , s f modular switch 1 module single pole one way 16 amp conforming to is3854 and isi marked complete all as direcred 18 nos , s f ceiling rose with earth terminal connection 3 terminal pvc polycarbonate isolated body of size 60x50mm 26 nos , s f modular socket 6a 3 pin 2 module conforming to is 1293 2019 and isi marked complete all as direcred 58 nos , s f modular socket 6 16a 3 pin 2 module conforming to is 1293 2019 and isi marked complete all as direcred 18 nos , s f modular pvc gang box screwless of 6 module for mounting of modular switches and sockets including blank plate for blank module 8 nos , all as per item no- 8.00 above but of modular pvc gang box 4 module 22 nos , all as per item no- 8.00 above but of modular pvc gang box 3 module 38 nos , all as per item no- 37.00 above but of modular pvc gang box 2 module 5 nos , sf modular white cover plate with frame 6 module 8 nos , sf modular white cover plate with frame 4 module 22 nos , sf modular white cover plate with frame 3 module 38 nos , sf modular white cover plate with frame 2 module 5 nos , supply and fix led aluminium housing of batten fitting 20 watt 240v 4ft cdlnw comprises of aluminium extruded channel in thermally conductive material with decorative end cap , s f mcb db spn conforming to ip 43 ik 09 with acrylic double door 12 way complete with din rail neutral and earthing bar 11 nos , s f mcb spn 63 amp 10 ka 230 volt c curve type 11 nos , s f mcb single pole 20 amp 10 ka 230 volt c curve type 81 nos , s f cable pvc insulated pvc sheathed armoured frls 1100v grade 2 core 6 sqmm stranded copper conductor electric cable laid on wall roof duct complete with proper saddling , supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole mcb of capacity 20 amp, 240 volts complete all as specified and directed 26 nos , m l for pvc insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross-sectional area 50 sq mm 3.5 core 140 rm , s f vtpn db 8 way suitable for flush mounting and surface mounting with 250 a copper busbar for each phase with 2 neutral bar 2 earthbar and cable ties , s f mccb tpn 100 amp icu 16 ka 415v with magnetic release complete all as specified and directed 8 nos , s f mccb 4 pole 160 amp icu 36 ka 415v with magnetic release complete all as specified and directed 2 nos , m l for snap- on trunking system with cover angles bends and all accessories and fitting of size 50x130 mm with 2- compartment fixing on wall complete all specified and directed 90 rm , s f modular bell push switch 1 module single pole one way 6amp isi marked 4 nos , s f in replacement with modular electric bell ding dong ac 230v single pole 4 nos //bid details 2 / 28
Tender For corrigendum : construction of drain, raising of cable duct, watering arrangements to earth pits and metal spreading and painting to control room at 220kv ss pulukurthy in omc circle,warangal
Tender For corrigendum : supply of shifting of secondary substation at workshop to frere basin compound - phase sequence testing and commissioning of ht cable , supply of straight through transition ht cable joint optional , making of ht cable transition joint pilc to xlpe optional , excavation of ht cable trench in soft soil or asphalt , ht cable trench excavation in concrete road optional , laying of ht xlpe cable 3cx240sqmm in excavated trench , laying of ht cable in rcc pipe or existing duct , supply of 200mm dia rcc pipe np2 class with collars , laying of rcc pipe and fixing of collars , supply of lt xlpe cable 3.5cx400sqmm to fp 6a , supply of lt xlpe cable 3.5cx400sqmm to fp 11 , supply of lt xlpe cable 3.5cx300sqmm to fp 1a , supply of lt xlpe cable 3.5cx300sqmm to fp 3 , supply of lt xlpe cable 3.5cx300sqmm to fp 4 , supply of lt xlpe cable 3.5cx300sqmm to fp 5 , supply of lt xlpe cable 3.5cx300sqmm to fp 6b , supply of lt xlpe cable 3.5cx300sqmm to fp 6c , lt cable trench excavation in asphalt paver area , laying of lt cable 3.5cx300 or 400sqmm in excavated trench , laying lt cable 3.5cx300 or 400sqmm in pipe or duct , supply of lt xlpe cable 3.5cx70sqmm to old cme building , excavation of lt cable trench for 70sqmm cable , laying of lt cable 3.5cx70sqmm in excavated trench , laying of lt cable 3.5cx70sqmm in rcc pipe or duct , cable termination material for 3.5cx70sqmm lt cable , cable termination installation for 3.5cx70sqmm lt cable , cable termination material for 3.5cx300sqmm lt cable , cable termination installation for 3.5cx300sqmm lt cable , cable termination material for 3.5cx400sqmm lt cable , cable termination installation for 3.5cx400sqmm lt cable , e-house foundation civil work , e-house shed supply and installation , rubble packing 250mm thick for cable trench reinstatement , stone metal 40-90mm layer for trench reinstatement , water bound macadam wbm layer for trench reinstatement , m10 grade rmc concrete levelling course , m40 grade rmc concrete road pavement , interlocking paver blocks 100mm thick , asphaltic macadam bitumen grade 60 70 regulating course , asphaltic concrete wearing course bitumen grade 60 70 , transporting surplus excavated material outside mbpa estate , dismantling of existing workshop substation equipment
Tender For supply of permanently lubricated high density polyethylene duct(plb-hdpe), 40/33mm dia, along with end cap, end plug, cable sealing plug and couplers, as per rdso/spn.tc/45/2013 rev.2 with amd 3.0 or latest [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking