Tender For supply of variable area flow meter rotameter for uranyl nitrate t-239 25 mm , supply of variable area flow meter rotameter for tbp solvent t-240 15mm , supply of variable area flow meter rotameter for hno3 t-243 15mm , supply of variable area flow meter rotameter for dm water t-244 15mm , supply of variable area flow meter rotameter for dm water 50mm , supply of polypropylene y type mesh or strainer 25 mm, flange ends ansi b 16.5 , erection of equipments or instruments etc and commissioning and handover
Tender For corrigendum : design, engineering, procurement, fabrication, inspection, testing, transportation, an supply of rotameter with and without transmitters as per mr
Tender For bid to ras bid to ras corrigendum : supply of wx9771615262 drg: 31611770128 rev: 00 condenser air evacuation packa ge (vacuum pump) 30scfm itemid: , w96716155317 drg: - rev: 00 complete vacuum pump (bare shaft vacuum pump) spec: he57016 rev: 04 itemi , w96716155465 heat exchanger for vacuum pump package. spec: he57016 rev: 04 size: - itemid: bh010 , wx9771615270 terminal plate for main motor of vacuum pump size: ----- itemid: bh010 , wx9771615289 heaters for main motor of vacuum pump size: ---- itemid: bh010 , wx9771615297 greasing arrangements for main motor of vacuum pump size: --- itemid: bh010 , w97716155067 bearing for motor of vacuum pump (30 scfm) (1set= 2nos) spec: he57016 rev: 04 size: to s , wx9771615300 terminal plate for rc pump mot or size: ---- itemid: bh010 , wx9771615319 heaters for rc pump motor size: ---- itemid: bh010 , wx9771615327 greasing arrangements for rc p ump motor size: ---- itemid: bh010 , wx9771615335 bearing for for rc pump motor (1set= 2nos) size: ---- itemid: bh010 , w96716155325 main motor for vacuum pump spec: he57016 rev: 04 size: - itemid: bh010 , wx9771615343 motor for recirculation pump for 30 scfm vacuum pump size: --- itemid: bh010 , w97716152033 temperature element for vacuum pump spec: he57016 rev: 04 size: - itemid: bh010 , w97716152041 thermowell for temperature element spec: he57016 rev: 04 size: - itemid: bh010 , w97716155822 pressure transmitter for vacuum pump system: 0-1 bar abs spec: he57016 rev: 04 itemid: b , w96716155244 drg: 31611770051 rev: 00 temperature transmitter for vacuum pump spec: he57016 rev: 04 i , w96716155813 level transmitter for vacuum pump spec: he57016 rev: 04 size: - itemid: bh010 , w96716155210 drg: 31611770047 rev: 00 differential pressure switch for vacuum pump. spec: he57016 rev , w96716155490 flow indicator cum switch for vacuum pump spec: he57016 rev: 04 size: - itemid: bh010 , w97716155733 drg: to suit original supply rev: 00 pressure gauge (0 to -1 bar) itemid: bh010 , w97716155741 drg: to suit original supply rev: 00 pressure gauge (service water) itemid: bh010 , w97716155466 temperature gauge 0-100 deg c, for vacuum pump heat exchanger size: 0 to 100 deg c dim. , w96716155457 differential pressure gauge for vacuum pump package duplex filter spec: he57016 rev: 04 , w97716155849 drg: to suit original supply rev: 00 air flow meter (rotameter) for vacuum pump system s , w97716155547 level gauge for vacuum pump separator tank spec: he57016 rev: 04 size: to suit original , w97716117106 supervision of commissioning lump sum per man day charges at site, including every expe , w97716117114 supervision of commissioning lump sum per visit charges (to & fro) including travelling
Tender For purchase of renewable energy practical equipments - equipments for renewable energy practices:, rc phase shift oscillator oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram, strain guage characteristics kitac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristics kit input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer input supply: 230 v / 50 hz ac with regulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibratedrotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation. measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter input supply: 230 v / 50 hz ac with regulated internal dc supply unit. measurement principle: buoyancy (archimedes principle) using displacer element. tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement of temperature using pt100 input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath. measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to 150 c (or suitable laboratory range). display unit: digital temperature indicator with direct c display. accuracy: high accuracy with linearized rtd signal conditioning circuit. sign
Tender For purchase of lab equipments for res dept - purchase of lab equipments for res dept, rc phase shift oscillator (iemcode:o001)specifications: oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram., strain guage characteristi cs kit(iemcode:o002)specifications: ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. no rs.10,000 2 table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristi cs kit(item code: o003)specifications:input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer(item code: o004)specifications: input supply: 230 v / 50 hz ac withregulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibratedrotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter(item code: o005)specifications: input supply: 230 v / 50 hz acwith regulated internal dcsupply unit. measurement principle:buoyancy(archimedesprinciple) using displacerelement tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement oftemperature using pt100(item code: o006a)specifications: input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to