Get complete information related to latest Camera Lucida Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Camera Lucida Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Camera Lucida Tenders.
Tender For bid to ras supply of short pass filter for visible wavelength range blocking greater then eual to tod5 761 1200nm , short pass filter for visible wavelength range blocking greater then eual to od5 506 1200nm , long pass filter for near ir range , offaxis parabolic mirror uv enhanced aluminium , concave mirror , optical chopper with chopper blade and controller , calcium fluoride caf2 crystal window , beta bbo crystal mounted in open ring holder thickness 0 point 1 mm , beta bbo crystal mounted in open ring holder thickness 1 mm , znte crystal mounted in open ring thickness 0.5 mm , znte crystal mounted in open ring thickness 0.2 mm , broadband thinfilm laser polarizer at 70 degree , z cut crystal quartz window for thz spectroscopy , hrfz silicon window plano plano
Tender For supply of various items of lab equipments for govt. p g college guna district guna (m.p.) under p m usha pariyojna 4th call - supply of various lab equipments items for govt. p g college guna district guna (m.p.) 4th call, waterand soil testing analysis kit (digital) : range ph 0 to 14.00 resolution ph 0.01 accuracy ph 0.01 1 digit temp. comp. 0 to 100 deg. c., water bath (06holes) : 6 hole8 ltrs., waterbath(12holes) :12 hole 20 ltrs., water distillation apparatus(single distillation unit 2 litre/hour) : single distillation 5 litres, analytical balance : least cosunt 0.0002g, analytical weight box : 1-100g, fractional weight box : 1-500mg, physical balance : 250gm accuracy 0.1g, digital balance : least count 1mg, single pandigital balance : 0.1mg 200g, digital photoelectric colorimeter : 8 filter,1 ml, digital potentiometer : with hot plate and electrodes, digital conductometer : with cell 1cc and 0.1cc, d.o. meter : polarographic do range: typically 0 to 90 mg/l (milligrams per liter) or 0 to 600% saturation.rdo (optical) do range: usually 0 to 50 mg/l or 0 to 500% saturation., digital naphelo/turbidity meter : digital turbidity cum nephelometer range:-, 200,1000 ntu/jtu resolution:- 0.01 ntu/jtu accuracy:- 3% fs, 1digit display:- 3 digit 7-segment led light source:- ir led detector:- photodiode sample system:- 60 x 25mm clear glass test tubes power:- 230 v 10% ac, 50 hz accessories:- test tube set of 2, operation manual, dust cover, polarimeter half shade : the specific rotation ( ) is a physical property defined as the optical rotation at a path length of 1 dm, a concentration of 10 g/l, a temperature (usually 20 c), and a light wavelength (usually sodium d line at 589.3 nm), melting point apparatus :melting-point measurement range: room temperature - 400 c setting rate of the starting temp. : 50 c~400 c 5 min; 400 c~50 c 7 min minimum digital display: 0.1 c size of the capillary: 1.4mm (outside diameter) 1.0mm (inside diameter), 90mm equipped with color camera and color monitor to observe melting point with ease validation program for standard samples 8 operator names can be storedgraphic lcd display to display all test parameters & test instructions, digital melting point apparatus :melting point measurement range : ambient to 300 deg c starting melting point temperature : settable from 50 to 300 deg c heating time : 3 minutes (up to 300deg c) cooling time : 5 minutes (from 300 deg c) accuracy : +/ 0.5 deg up to 200 +/ 0.8 deg from 200 to 300 temperature display resolution : 0.1 deg c rate of heating (deg c per minute), abbe refractometer : safety bs en 60950-1:11/2006 emc en 55024 : 10/2003 en 55020 : 11/2005, tlc kit : outstanding standardization and quality control exceptional adherence, hardness and surface homogeneity. analyzing samples with high matrix- load without sample preparation. multiple samples analyzed in parallel.highly cost-efficient, fast and economical, centrifuge : 6000rpm, corkboring machine :adjustable guide that permits holes to be bored in any part of a stopper, the knurled chuck - 9/16" (14mm) shank of the eight, plated-steel borers included with the unit. the steel borers range from 3/16" to 5/8" (4.8mm to 15.9mm) in 1/16" (1.6mm) increments,, distillation apparatus : single distillation 5 litres, oven hot air : 14" 14" 14 , voltage stabilizer : 2kv, vertex shaker : 6 tube capacity, mixer small : moter capacity 900 watt, water bath(cu) : 4 , heating mantle with energy regulator : 500 w,2litre, single crucible heater : helical wire coil moldatherm insulation platinel ii thermocouple with 10tm compensated lead wire and polarized plug ceramic fiber hearthplate programmable heat-up to setpoint temperature indicates setpoint and process temperatures temperature: 1200 c (2192 f) maximum crucible sizes: 5 (top vestibule id) x 8 (heated depth), water bath rectangularsingle walled : 6 hole 8 ltrs., water bath rectangular :2 hole, kjeldahl distillation unit : unit of 3 tests, microwave oven : 30 ltr co
Tender For supply of fast start essential dna probes master 10 multiply 5 m for upto 5000 reactions of 20 ul final volume , light cycler 480 multiwell plate 96, white,50 plates with sealing foil , nitrile powder free gloves medium , nitrile powder free gloves small , ethyl alcohol 500 ml , sterile racked filter tips 10 ul , aerosol barrier tips , 2 point 0 ml microcentrifuge tubes , dneasy blood and tissue kit for dna isolation 250 reaction , nucleospin gel and pcr clean up upto 50 reaction , marker pen fine tip blue , marker pen fine tip red , marker pen fine tip black , test tube brush , pointed forceps 5 inch , minute pin length 15 mulitply 0 point 10 diameter , eppendorf tube 2 ml , entomological needle 13 point 5 cm , eppendorf tube stand 2 ml , lab soaker , dipper enamel , pipette plastic 5 ml , pipette plastic 10 ml , rubber teat for 10 ml pipette , pasteur pipette glass 3 ml with rubber teat , forceps , minute pin no 2 , eppendorf tube 1 point 5 ml , pyrethrum extract , dneasy blood and tissue kit 250 reaction , rneasy mini kit 250 reaction , taqman tm multiplex master mix 5 ml , reliance one step multiplex rt- qpcr supermix, 200 multiply 20rxns, 1 ml , 0 point 2 ml 8 tube pcr strips without caps,low profile,white , 0 point 2 ml 8 tube pcr strips without caps,optical,ultraclear , promega gel loading dye 6x , ethanol,absolute molecular biology grade 500 ml , premium grade ethanol 100 percent 500 ml , 1 point 5 ml tube , 0 point 2 ml tube , 2 ml tube , tips 2 to 10 ul filter tips , tips 2 to 20 ul filter tips , tips 20 to 200 ul filter tips , tips 200 to1000 ul filter tips , rnaseaway decontimation reagent 250 ml , asn salt 5 g , lb agar 500 g , 1m iptg , lb broth 500 g , kanamycin sulphate 1 g , tetracycline 1 g , calcium anhydrous chloride 500 g , carbenicillin disodium salt 1 g , storage box for 1 point 5 ml microtubes, pp clear type,100 holes , sodium hypochlorite, hi ar tm acs, 4 percent w v solution ) /bid number : gem/2026/b/7593707 * /dated: 27-05-2026 & & / bid document 1 / 45
Tender For tender for supply of vme analog input 48(vai 48) cca kit , vme digital output (vdop24) cca kit , vme data path mini computer pentium 3(vdmc p3) , ir sensitive 0.1 lux camera , vme gigabit optical switch(vgos8) cca , emi filter dc , circuit breaker din moun 5a , lamp-red , pushbuttons/indicator rpm , pushbuttons/indicator , motorised zoomas , continuous level , sensor(tank) 0-5m , continuous level , sensor(tank) 0-5m , rugeged rackmount console processor , penel meter analog 0-160 bar , penel meter analog 0-350 rpm , penel meter analog 24-26.5 degas , penel meter analog 0-350 rpm , power supply repeater-is , eot lever with repeater mcr , eot lever with repeater engine room , citadel pressure transducers , circuit breaker din moun 20a , fuses fast-acting-1a
Tender For corrigendum : short term e-bid for rate contract cum supply and empanelment of surgical items - "syphilisantibody (rapid) detection kits1. the assay should be based on rapid chromatographic immunoassay for qualitative detection of antibodies (lgg, lga & lgm) to tp in serum, plasma & whole blood.2. the assay should utilize recombinant treponemal antigens i.e. tp15, tpl7, tp47 against syphilis.3. the assay should be in card format.4. adequate documents detailing the principle components, bio- safety methodologies, validity criteria, interpretation of results, performance characteristics storage conditions, limitation of assays manufacturing & expiry dates should be provides with each kit.5. the kit should have approval of the statutory authority in its country of origin.6. in case of imported kits it should be registered and licensed under the provisions of drugs & cosmetics act and rules and/or medical devices rules 2017 in india.7. in case of indigenous manufacturers should be licensed under the provisions of drugs & cosmetics act and rules and or medical devices rules 2017 issued by the competent authority defined under drugs and cosmetics act, 1940.8. the kit should have minimum shelf- life of 5/6th or 12 months (whichever is more) at the port of discharge of consignees.9. read result time should not be more than 20 minutes.10. assay should have sensitivity 100% & specificity 99 %or more with documentary evidence.11. the storage & transport temperature of the kit should be 2-30 c.12. the pack size should not be more than 50 tests wherein each test is individually", bed side leucodepletion filters for blood transfusion (for 2 unit of red cell) [ne32b] 1. filters should be able to leucodepletered cells form leukocytecontamination separately for 1 unitof red cells and for 2 units of redcells each.2. filters should be having thecapacity of log 4 reduction(99.99%)3. filters should not carry anycharges it should be neutrallycharged.4. filters material should bepolyester woven / non- woven.5. leukocytes should beconsistently averaging less than0.5x105 residual leucocytes forone unit of red cell and 0.2*106for two units of red cell. rbcrecovery should be averaging morethan 90%.6. filters should have hard / softhousing for optical monitoring.7. filtration loss should not bemore than 35 ml for one unit redcell.8. should have integrated 40 m,micro aggregate filter.9. should be us fda/ europeance certified., hepatitis b surface antigen (elisa) testing kits iv generation/high sensitiveshould have microplate elisa coated with either polyclonal or monoclonal antibodies to hbsag and either polyclonal or monoclonal antibodies in conjugate. the assay should be able to detect all the 11 subtypes (ad & ay subtype) including mutant strains. the assay should be able to detect surface antigen to hepatitis b virus., hbsag (rapid test)